Output Control of ITER Vertical Stabilization Converter with Circulating Current Technique

순환전류를 이용한 ITER Vertical Stabilization 컨버터의 출력 제어

  • Published : 2009.10.20

Abstract

This paper investigates the operation of ITER(International Thermonuclear Experimental Reactor) Vertical Stabilization(VS) converter with circulating current. The VS converter has two subunits in parallel. The subunit is composed two back-to-back 12 pulse thyristor converter in series. The circulating current free technique can not always maintain the closed path for the load current because of a dead time zone of the converter operation at the region of the load current inversion. The complex circulation current technique for the load current inversion with VS converter can achieve the fast response and always maintain the closed path for the load curret. The paper proposes the new circulating current algorithm for the load current inversion of ITER VS converter and proves the performance of the circulating current technique with PSIM simulation study.

ITER 핵융합 장치에 사용되는 Vertical Stabilization(VS) 컨버터는 4상한 운전 모드의 대용량 부하에 전력을 공급하기 위해서 4개의 직렬구조 12펄스 컨버터를 역병렬 연결하여 구성한다. 스위칭 소자로 싸이리스터를 사용하는 VS 컨버터는 정역 운전모드 변환과정에서 컨버터의 안전운전을 위해 Dead Time 구간을 필요로하며, 이 과정에서 유도성 부하에 영(Zero)전류 불연속 구간이 발생하는 단점이 있다. VS 컨버터의 출력 전류제어에 순환전류를 이용할 경우에는 빠른 정역 운전모드 변환이 가능하며, 부하에 발생하는 영전류 불연속 구간을 제거할 수 있다. 본 논문은 ITER VS 컨버터에서 출력전류의 정역 운전을 위해 순환전류를 이용하는 부하 전류제어 알고리즘을 제안하고, PSIM 시뮬레이션을 통해 결과를 검증하였다.

Keywords

References

  1. M. Shimada, et al., 'Progress in the ITER Physics Basis, Chapter 1: Overview and summary', Nucl. Fusion 47, S1-S17, 2007 https://doi.org/10.1088/0029-5515/47/6/S01
  2. E. Gaio et al., 'The control system of the ITER vertical stabilization converter', Fusion Engineering and Design, 66-68 (2003) 719-725 https://doi.org/10.1016/S0920-3796(03)00391-0
  3. P.C. Sen, 'Thyristor DC Drives', ISBN-0471060704, New York, John Wiley, 1981
  4. J. K. Ji, S. K. Sul, M. H. Park, K. T. Kim & K. H. Kim, 'Rolling Mill DC Motor Drive System Using Predictive Current Controller', KIEE Trans., Vol. 42, No. 12, pp. 1387-1396, 1992, Dec
  5. Jun-Keun Ji Seung-Ki Sul,'Operation analysis and new current control of parallel connected dual converter system without interphase reactors', Proc.. of IEEE IECON'99, pp. 235-240, 1999
  6. 지준근, '상간리액터 없는 병렬연결 듀얼컨버터 시스템 의 동작해석과 새로운 전류제어', 대한전기학회논문지: 전기기기및에너지변환시스템부문B, Vol. 49, No.7, pp. 488-493, 2000. 7
  7. 정교범, 'Vernier 모드 2-모듈 TCSC의 특성 해석을 위한 싸이리스터 점호각 계산', 전력전자학회 논문지, 제5권 제1호, pp. 54-62, 2000. 2
  8. SJ Jeong, SH Song, 'Improvement of predictive current control performance using online parameter estimation in phase controlled rectifier', IEEE Trans. on Power Electronics, Vol. 22, No. 5, pp. 1820-1825, 2007, Sept https://doi.org/10.1109/TPEL.2007.904235
  9. 송승호, '대전류 코일 전원 공급장치를 위한 12펄스 듀얼 컨버터의 전류제어', 전력전자학회 논문지, 제7권 제4호, pp. 332-338, 2002. 8
  10. S.H. Song, 'Current Control of 12-Pulse Regenerative Converter for High Current Magnetic Power Supply', Electric Power Components and Systems, Vol. 34, pp. 917-926, 2006 https://doi.org/10.1080/15325000600561621
  11. Fu, P et al., 'Design and test results for the PF power supply system of EAST', Fusion Science and Technology. Vol. 54, No. 4, pp. 1003-1009, 2008, Nov https://doi.org/10.13182/FST08-A1916
  12. Muhammad H. Rashid, 'Power Electronics: Circuits, Devices and Applications', Pearson Education, 3rd ed., ISBN-10: 0131228153, 2003
  13. ITER DDD report N 41 DDD 16 01-07-06 R 0.3, 2001, July