Abstract
Microstrip interdigital filter is designed with the width and length of a resonator, the gap distance between resonators and the location of a tap. When designing filters, it is a benefit to design with few design parameters comparing to many design parameters. In this paper we design and implement two microstrip interdigital filters operating in the UWB(Ultra Wide-Band) frequency band, one using a fixed width of a resonator and the other using a different width of resonators. The test results of the implemented filters show that the low-band high filter with a fixed width has the insertion loss of 1.49dB, -10dB band width of 720MHz, -35.7dBattenuation at 4.8GHzand below -13dB of S11. The filter with a different width of resonators has the insertion loss of 1.6dB, -10dBbandwidth of 1.63GHz and below-8dBof S11.
마이크로스트립 인터디지털(interdigtal) 여파기는 공진기의 폭, 길이, 공진기 사이의 간격과 탭의 위치로 설계하는데, 설계파라미터의 수를 줄이는 것이 구현 측면에서 유리하다. 본 논문에서는 마이크로스트립 인터디지털 여파기의 설계파라미터 중에서 공진기의 폭을 고정시킨 것과 서로 다른 폭을 갖는 두 종류의 여파기를 국내 UWB(Ultra Wide-Band) 주파수 대역에서 설계 및 구현하였다. 여파기의 성능 측정 결과 공진기의 폭을 고정한 low-band high 여파기의 삽입손실은 1.49dB, -10dB 대역폭은 750MHz였고, 4.8GHz에서 -35.7dB의 감쇄특성을 가졌으며, S11은 -13dB 이하로 측정되었다. 공진기의 폭이 서로 다른 low-band 여파기는 삽입손실 1.6dB, -10dB 대역폭은1.63GHz로 측정되었고, S11은 -8dB 이하로 측정되었다.