Domestic Conditions on the Electrolytic Corrosion Protection of Buried Metallic Structures

지하매설 금속구조물의 전식방지 국내 현황

  • 이현구 (한국전기연구원 전력시스템연구본부) ;
  • 하태현 (한국전기연구원 전력시스템연구본부) ;
  • 최정희 (한국전기연구원 전력시스템연구본부) ;
  • 정호성 (한국철도기술연구원 집전전력연구실) ;
  • 배정효 (한국전기연구원 전력시스템연구본부)
  • Published : 2009.04.30

Abstract

With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Most often DC-powered traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper investigates the domestic conditions on the electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems by survey.

누설전류는 의도된 회로 이외의 경로로 흐르는 전류를 말하며, 일반적으로 도시철도의 급전 시스템은 레일을 부극선으로 사용하기 때문에 레일이 대지와 완벽하게 절연되어 있지 않다면 레일을 통해 흐르는 전류의 일부는 누설전류로 땅속을 흐르게 된다. 이때 토양을 통해 누설 전류가 유출되는 레일과 지하매설 금속구조물에서 전식이 발생하게 된다. 본 논문에서는 국내 도시철도 운행지역 인근 지하매설 금속구조물의 전식방지 현황을 설문조사를 통하여 조사하였다.

Keywords

References

  1. 이재영, "직류전기철도시스템에서의 누설전류에의한 전식방지에 대한 연구", 2005년도 한국철도학회 추계학술대회 논문집, pp. 112-117, (2005)
  2. "Electrolytic Corrosion in DC Powered Transit Systems ", lIT Research Institute, Chicago, IL, 8 Reports Prepared for the National Cooperative Transit Research and Development Program Project 48-1, lRB, National Research Council, Washington DC, 1985-1987, (1987)
  3. Steve Case, "DC Traction Stray Current Control So What's the Problem?", The Institution of Electrical Engineers, (1999)
  4. M J. Szeliga, "Stray Current Corrosion - The Past, Present, and Future of Rail Transit Systerrs", NACE International, (1994)
  5. 하윤철, 배정효, 하태현, 이현구, 김대경, “배설배관과 직류전기철도의 표유전류 간섭분석" 한국 가스학회지 제10권 제3호, (2006)
  6. 표준전기공학강좌 17, 개정 전기철도
  7. 전기설비기술기준, 산업자원부 공고 제 2007-10호, 개정 2007.1.17,(2007)
  8. 이현구, 하윤철, 하태현, 최정희, 김대경, 배정효, “귀선자동개폐장치를 이용한 차량기지 전식방지법”, 2007년도 대한전기학회 EMECS 추계학술대회, (2007)
  9. S. Case, “DC Traction Stray Current Control”, IEE, Savoy Place, London WC2R 0BL, UK, (1999)
  10. 서울특별시 도시철도 9호선 1단계구간(상부부분) 민간투자사업 실시설계 전기부식 방지 분야 보고서, 서울시메트로9호선주식회사, (2006)
  11. 직류전기철도에 의한 전식조사 보고서, 서울특별시 지하철공사, (1987)
  12. IEC 62128-2, Railway applications - Fixed installations - Part 2: Protective provisions against the effects of stray currents caused by d.c. tractionsystems, (2003)
  13. NACE Standard RP0169-2002, Control of External Corrosion on Underground or Submerged Metallic Piping Systems, NACE International, (2002)
  14. ASTM G 165, Standard Practice for Determining Rail-to-Earth Resistance, (2005)