Abstract

We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.

Keywords

References

  1. 산업자원부, '건축환경을 고려한 BIPV 용 태양전지모율 및 제조기술개발, 산업자원부, 2007. 10, pp .419-445
  2. 유권종 외, 2007 년 세계 태양광발전산업현황, 대한전기학회 하계학술대회, 2008. 7. pp .1132-1133
  3. J.H. So, A Performance Evaluation and Analysis of Photovoltaic Systems with Monitored Data, Doctoral Dissertation, Kwang-Woon University, South Korea, 2006, pp.100-101
  4. DTI, Monitoring of Roof Mounted Photovoltaics at the Ecos Milennium Environmental Centre, S/P2/00388/REP, URN04/557, 2004, pp.7-9
  5. DTI, Monitoring of Integrated Photovoltaic Facade for Sandwell Metropolitan Borough Council, ETSU S/P2/00326/REP, URN04/557, 2002