Production and Application of the Dose Calculation Program which used MS EXCEL and Bit System

MS EXCEL 및 Bit system을 이용한 피부선량 계산 프로그램의 제작 및 응용

  • Kim, Sung-Chul (Department of Radiological Science, Gachon University of Medicine and Science) ;
  • Kim, Chong-Yeal (Department of Radiation Science & Technology, Chonbuk National University)
  • 김성철 (가천의과학대학교 방사선학과) ;
  • 김종일 (전북대학교 방사선과학기술학과)
  • Published : 2009.03.31

Abstract

The medical diagnostic examination using ionizing radiation has improved the patients' life and brought revolution in medical examination along with the mechanical development. However, the development of medical imaging systems has also been the reason to increase the patients' exposure for ionizing radiation. ICRP recommends that each country adopts diagnostic reference levels depending on regional and national situations. The Korea Food & Drug Administration suggested the dosimetry measurement guideline for patients in 2007. Nonetheless, in reality, it is hard to know the skin dose of the patients when applying a x-ray since there is no radiation dosimeter in most of clinical situation. Therefore, this study sets a program based on the bit system to figure out easily the skin dose of a patients using MS Excel program in the PC setting. The results showed 10% better outcome.

전리방사선을 이용한 의료진단검사는 장치의 발전과 더불어 환자의 삶을 개선시키고 의료검사의 혁명을 가지고 왔다. 하지만 이러한 의료영상의 발전은 대중에 의한 전리방사선피폭의 증가의 원인이 되었다. 이러한 가운데 ICRP에서는 각 국가 및 지역의 실정에 맞게 진단참고준위를 사용하도록 권고하고 있으며, 우리나라에서도 2007년 식품의약품안전청에서 환자선량측정 가이드라인을 제시하였다. 하지만 임상에서는 대부분 선량계가 없어 X선 검사시 환자피부선량을 알 수가 없는 것이 현실이다. 이에 저자는 bit system을 이용하여, PC상에서 엑셀프로그램을 이용하여 간단하게 환자선량을 알 수 있게 프로그램화 하여 그 유용성을 검토하였으며, 그 결과 실측값과 계산값은 약 10% 정도의 차이로 우수한 결과를 나타내었다.

Keywords

References

  1. 김우란, 이춘식, 이재기 : 진단X선에 의한 성인의 진단행위별 유효선량평가, 방사선방어학회지, 27(3), 155-164, 2002
  2. 大稼昭義 : X線檢査における 患者被曝低感 の技術的硏究, 日本放射線技術學會雜誌 39(5), 760-778, 1983
  3. ICRP supporting Guidance 2 : Diagnostic referencelevels in medical imaging : Review andadditional advice, ICRP committee 3, 33-52,2002
  4. 식품의약품안전청 : 환자선량측정 가이드라인, 방사선안전관리시리즈 No. 14, 1-44, 2007
  5. 김정민, 석진용 : 촬영조건에 의한 환자 피폭선량의 자동계산 프로그램, 대한방사선기술학회지, 25(2), 35-38, 2002
  6. 김정민, 허준, 임태랑, 석전유치, 앵정달야 : 흉부 X선 사진농도로 부터 표면선량을 산출하는 방법, 대한방사선기술학회지, 22(1), 13-20, 1999
  7. Japan society of radiological technology Ibaragibranch office : Non-Dosimeter-Dosimetry(NDD)Method, Japan socity of radiological technologyIbaragi branch office, Mito, 1996
  8. 김정민, 김성철, 최종학 외 : 방사선영상정보학, 신광 출판사, 141-145, 2008
  9. IAEA : International basic safety standards forprotection against Ionizing radiation and for thesafety of radiation sources, IAEA safety seriesNo. 115, 1996
  10. 김유현 : 입사표면선량 측정방법과 방사선사의 역할, 방사선기술과학, 28(3), 173-191, 2005
  11. Richard R. Carlton, Arlene M : Adler Principlesof radiographic imaging, 4th ed : 499-500, 2006
  12. E. Stephen Amis, Priscilla F. Butler, KimberlyE. Applegate : American college of radilogywhite paper on radiation dose in medicine,Journal of the american college of radiology,4(5), 2007
  13. 김성철, 최강묵, 신성일, 윤종민, 이선숙, 허준 : X선 피폭선량 경감용 Key-filter의 평가, 대한방사선기술학회지, 20(1), 61-64, 1997
  14. Okka W. Hamer, Claude B. Sirlin, MichaelStrotzer, Ingitha Borisch, Niels Zorger, StefanFeuerbach, Markus Volk : Cheat radiographywith a flat-panel detector : Image quality withDose Reduction after copper filtration, Radiology,237(2), 691-700, 2005 https://doi.org/10.1148/radiol.2372041738
  15. 김영근 : X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량감소와 대조도개선에 관한 연구,23(1), 91-96, 2000