전기다리미의 발화원인 판정에 관한 현상학적 고찰

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron

  • 문용수 (서울시립대학교 대학원 재난과학과) ;
  • 공하성 (청운대학교 건축설비소방학과) ;
  • 이종화 (청운대학교 건축설비소방학과)
  • Mun, Yong-Soo (Dept. of Disaster Science, The Graduate Course University of Seoul) ;
  • Kong, Ha-Sung (Dept. of Building Equipment & Fire Protection System, Chungwoon University) ;
  • Lee, Jong-Hwa (Dept. of Building Equipment & Fire Protection System, Chungwoon University)
  • 발행 : 2009.03.31

초록

This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

키워드

참고문헌

  1. 김창종, '전기화재의 분석과 규명', 한국조명전기설비학회지(1995), Vol.9, No.2, pp.10-16
  2. 이종호, 긴두현, '전기화재 조사를 위한 분류체계 개발', 한국안전학회지(2005), Vol.20, No.3, pp.53-57
  3. 윤명오,'화재조사의 이론과 실제', 서울시립대학교 도시방재안전연구소(2006), pp.175-176
  4. 최충석,김현우,이경섭,이춘하,임양수,정재희, '전기화재공학', 동화기술(2004), pp.81-91
  5. 화재보험협회, '전기화재(발생기기별원인)', (1979) pp.24-128
  6. 화재조사팀 편저, '현장실무자를 위한 화재원인 조사기법', 인천광역시 소방본부(2003)
  7. http://cafe.naver.com/gikang/697
  8. http://www.duplex.co.kr/ (주)양일상사