Flexural Behavior of Concrete Beams Reinforced with Lap Spliced FRP Bar

겹이음된 FRP 보강근으로 보강된 콘크리트 보의 휨거동

  • 오홍섭 (국립진주산업대학교 토목공학과)
  • Received : 2008.07.02
  • Accepted : 2008.04.25
  • Published : 2009.01.30

Abstract

This is a part of the extensive ongoing investigation being carried out by author to develop appropriate design procedure of the concrete member reinforced with FRP rebars instead of conventional steel rebars. This study presents the experimental results of a research programme to assess the structural characteristics of spliced rebar in reinforced concrete members with FRP reinforcement. The test variables are the diameter of FRP rebar and the embedment length. The development length (ld) was calculated according to the ACI 440 for FRP rebars in concrete. A total of 14 concrete beams reinforced with spliced FRP rebars and 4 reference beams reinforced with non-spliced FRP rebars were tested. The effects of bar size (10, 13, 16 and 19 mm) and splice length (from 0.72 to 1.58ld) on the bond strength were empirically evaluated. The test results indicate that a modification factor of 1.3 and 1.6 is relatively sufficient for the bond development length of glass FRP rebars in order to achieve an adequate tension lap splice length.

본 연구는 저자가 수행하고 있는 FRP로 보강된 콘크리트 보의 거동연구에 관한 일련의 연구 중 일부로서 본 연구에서는 인장보강근이 겹이음된 콘크리트보의 휨거동에 대한 실험적 연구결과를 제시하였다. 실험변수로는 보강근의 직경과 보강근의 겹이음길이를 적용되었으며, 총 14개의 겹이음된 실험체와 4개의 겹이음되지 않은 기준실험체에 대한 휨실험을 실시하여 각 실험변수인 보강근의 직경(10, 13, 16, 19mm)과 겹이음길이(0.72부터 1.58ld)에 대한 실험결과를 정리하였다. 각 보강근의 겹이음길이는 ACI 440에서 제시하고 있는 FRP 보강근에 대한 기준을 적용하였으며, 실험결과에서 사용된 FRP 보강근의 경우, 기준에서 제시하고 있는 부착길이에 대한 1.3과 1.6의 계수가 충분한 것으로 나타났다.

Keywords

References

  1. Pecce M., Manfredi G. and Cosenza E., "Experimental response and code models of GFRP RC beams in bending," J. Compos. Constr. 4 4, 2000, pp. 182-190 https://doi.org/10.1061/(ASCE)1090-0268(2000)4:4(182)
  2. Houssam A. Toutanji, Mohamed Saafi "Flexural Behavior of Concrete beams Reinforced with Glass Fiber-Reinforced Polymer(GFRP) Bars," ACI Structural Journal, Vol. 97, No. 5, 2000, pp. 712-719
  3. Benmokrame B., Chaallal O. and Masmoudi R. "Flexural Response of Concrete Beams Reinforced with FRP Reinforcing Bar," ACI Structural Journal, Vol. 93, No. 1, 1996, pp. 46-55
  4. Theriault M. and Benmokrane B., "Effects of FRP reinforcement ratio and concrete strength on flexural behavior of concrete beams," J Composite Construction Vol. 2, 1998, 1, pp. 7-16 https://doi.org/10.1061/(ASCE)1090-0268(1998)2:1(7)
  5. ACI 440.1R-01. Guide for the design and construction of concrete reinforced with FRP bars. ACI Committee 440, American Concrete Institute, Farmington Hills, MI, 2001. p. 41
  6. ISIS Canada: Design Manual 3. Reinforcing concrete structures with fiber reinforced polymers. The Canadian Network of Centers of Excellence on Intelligent Sensing for Innovative Structures, University of Manitoba, Winnipeg, Manitoba, Canada, September 2001, p. 207
  7. Benmokrame B., Tighiouart B., and Th$\acute{e}$riault M., "Bond strength of FRP rebarsplices", Proc. of the third international symposium on Nonmetallic (FRP) reinforcement for concrete structures (FRPRC-3), edited by Japan Concrete Institute, Sapporo, Japan, 1997, pp. 405-412
  8. Pleiman L.G., "Tension and bond pull-out tests of deformed fiberglass rods", Final Report for Marshall-Vega Corporation, Marshall, Arkansas, Civil engineering department, Fayetteville, Arkansas, USA, 1987, pp. 5-11
  9. Pleiman L.G., "Strength modulus of elasticity, and bond of deformed FRP rods," Advanced Composites Materials in Civil Engineering Structures, Proc. of the Specialty Conference, Materials Division, ASCE, 1991, pp. 99-110
  10. Faza SS, GangaRao HVS., "Bending and bond behavior of concrete beams reinforced with plastic rebars," Transportation Rearch Record 1290, 1990, pp. 185-193
  11. Ehsani, M. R., Saadatmanesh H., and Tao S., "Design recommendation for bond of GFRP rebars to concrete," J of Structural Engineering, Vol. 122, No. 3, 1996, pp. 247-257 https://doi.org/10.1061/(ASCE)0733-9445(1996)122:3(247)
  12. Chaallal O. and Benmokrane B., "Physical and mechanical performance of an innovative glass-fiber-reinforced plastic rod," Canadian Journal of Civil Engineering, Vol. 20, No. 2, 1993, pp. 254-268 https://doi.org/10.1139/l93-031