Detection of Tendon Tears by Degree of Linear Polarization Imaging

  • Kim, Ji-Hoon (Biomedical Engineering, Northwestern University) ;
  • Oh, Jung-Hwan (Mechanical Engineering, Pukyong National University) ;
  • Kang, Hyun-Wook (Innovation Center, American Medical Systems, Inc) ;
  • Lee, Ho (School of Mechanical Engineering, Kyungpook National University) ;
  • Kim, Jee-Hyun (School of Electrical Engineering and Computer Science, Kyungpook National University)
  • Received : 2009.09.15
  • Accepted : 2009.10.14
  • Published : 2009.12.25

Abstract

A Stokes polarimetry imaging (SPI) system was developed and utilized to detect tendon tears by constructing the degree of linear polarization (DOLP) image maps after linearly polarized light illumination. The micro and partial-thickness tears of turkey tendons were made and imaged by the SPI system at different incident polarization angles (IPA) with different mechanical loads on the tendon. The micro and partial-thickness tendon tears were detected by the DOLP images due to weak birefringence around the tears. The tendon tears were detected by a highest DOLP contrast at longest visible wavelength (Red, 650 ${\pm}$ 50 nm). All polarized images showed modulated DOLP as the incident polarization angle (IPA) was varied. The varying DOLP allowed the optimal detection of the micro and partial-thickness tendon tears at a certain IPA. The SPI system with variable IPA and spectral information can improve the detection of the tendon tears by higher visibility of fiber orientations, and thereby improve diagnosis and treatment of the tendon related injuries.

Keywords

References

  1. H. Ellman, “Diagnosis and treatment of incomplete rotator cuff tears,” Clin. Orthop. Relat. Res. 254, 64-74 (1990).
  2. S. K. Goergen, W. G. Bradley Jr., J. Liu, J. K. Tam, M. D. Dubin, P. J. Pema, L. M. Teresi, J. Jordan, and D. Morrison, “Improving the diagnostic accuracy of MR in the detection of infraspinatus tendon injuries,” J. Comput. Assist. Tomogr. 20, 829-833 (1996). https://doi.org/10.1097/00004728-199609000-00032
  3. S. A. Teefey, D. A. Rubin, W. D. Middleton, C. F. Hildebolt, R. A. Leibold, and K. Yamaguchi, “Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases,” J. Bone. Joint. Surg. Am. 86, 708-716 (2004). https://doi.org/10.2106/00004623-200404000-00007
  4. J. H. Kim, J. Oh, T. E. Milner, and J. S. Nelson, “Hemoglobin contrast in magneto motive optical doppler tomography,” Opt. Lett. 31, 778-780 (2006). https://doi.org/10.1364/OL.31.000778
  5. J. H. Kim, J. Oh, T. E. Milner, and J. S. Nelson, “Imaging nanoparticle flow using magneto-motive optical doppler tomography,” Nanotechnology 18, 035504 (2007). https://doi.org/10.1088/0957-4484/18/3/035504
  6. J. Oh, H. Lee, and J. Kim, “Detection of magnetic nanoparticles in tissue using magneto-motive DP-OCT,” J. Opt. Soc. Korea 11, 26-33 (2007). https://doi.org/10.3807/JOSK.2007.11.1.026
  7. S. G. Demos and R. R. Alfano, “Optical polarization imaging,” Appl. Opt. 36, 150-155 (1997). https://doi.org/10.1364/AO.36.000150
  8. S. G. Demos, A. J. Papadopoulos, H. Savage, A. S. Heerdt, S. Schantz, and R. R. Alfano, “Polarization filter for biomedical tissue optical imaging,” Photochem. Photobiol. 66, 821-825 (1997). https://doi.org/10.1111/j.1751-1097.1997.tb03231.x
  9. P. J. Wu and J. T. Walsh, “Stokes polarimetry imaging of rat tail tissue in a turbid medium: degree of linear polarization image maps using incident linearly polarized light,” J. Biomed. Opt. 11, 014031 (2006). https://doi.org/10.1117/1.2162851
  10. S. G. Demos, H. B. Radousky, and R. R. Alfano, “Deep subsurface imaging in tissues using spectral and polarization filtering,” Opt. Exp. 7, 23-28 (2000). https://doi.org/10.1364/OE.7.000023
  11. W. B. B. Wang, J. H. Ali, R. R. Alfano, J. H. Vitenson, and J. M. Lombardo, “Spectral polarization imaging of human rectum-membrane-prostate tissues,” IEEE J. Select. Topics Quantum Electron. 9, 288-293 (2003). https://doi.org/10.1109/JSTQE.2003.813301
  12. M. O'Brien, “Structure and metabolism of tendons,” Scand. J. Med. Sci. Sports 7, 55-61 (1997). https://doi.org/10.1111/j.1600-0838.1997.tb00119.x

Cited by

  1. Real-time Measurement of Full Field Retardation Near Quarter Wavelength vol.16, pp.4, 2012, https://doi.org/10.3807/JOSK.2012.16.4.457
  2. Lane Detection Algorithm for Night-time Digital Image Based on Distribution Feature of Boundary Pixels vol.17, pp.2, 2013, https://doi.org/10.3807/JOSK.2013.17.2.188
  3. Calibration of Measurement of Multiple Polarization Singularities vol.19, pp.4, 2015, https://doi.org/10.3807/JOSK.2015.19.4.397