A Study on Numerical Analysis of Thermal Flow in Solar Lamp Bank

솔라 램프뱅크 내의 열유동 수치해석에 관한 연구

  • 김성대 (성균관대학교 대학원 기계공학과) ;
  • 유성열 (성균관대학교 대학원 기계공학과) ;
  • 백상화 (국방과학연구소 종합시험단 2부) ;
  • 이정용 (국방과학연구소 종합시험단 2부) ;
  • 박소진 (충남대학교 화학공학과) ;
  • 김철주 (성균관대학교 기계공학부) ;
  • 고한서 (성균관대학교 기계공학부)
  • Published : 2008.04.30

Abstract

A three-wavelength solar bank is a very important part for a solar simulator with commercial superlux lamps. It is projected metal halide lamps to satisfy following points simultaneously: $\pm$10% of uniformity for irradiance of target area and irradiance in each wave region, and $1,232W/m^2$ of maximum solar irradiance in summer. The developed solar lamp bank has been analyzed numerically by commercial programs in this study to carry out experiments. In conclusion, designed B-type heat lamp is not concentrated in one place than designed A-type heat lamp, it is spreaded widely, and it was proved numerical computation. We suggest that solar simulator is applied to actual experiment test through heat flow numerical analysis in solar lamp bank and the lamp is applied private industry or the military using complex environmental assessment test.

Keywords

References

  1. MIL-STD-810F, Method 505.4, "Solar Radiation", Department of Defense, 2000
  2. W. Budde, "Optical Radiation Measurements", Vol. 4, Academic Press, New York, 1983
  3. F. Grum and R. J. Becherer, "Optical Radiation", Measurements Vol. 1, Academic Press, New York, 1982
  4. R. Danial Overheim and David L. Waguer, "Light and Color", John Willy & Sons, New York, 1982
  5. Hecht, "Optics", Addison-Wesely, p. 53, New York, 1987
  6. R. Byron Bird, "Transport Phenomena", John Willy & Sons, pp. 291-297, New York, 1976
  7. Baek Sang Hwa, "J Korean Ind. Eng. Chem.", Vol 10, No. 8, pp. 1147-1154, 1999
  8. James R. Welty, "Fundamentals of Momentum, Heat and Mass Transfer", John Willy & Sons, pp. 353-378, pp. 428-444, New York, 1982
  9. Hyun Ju Park, Study on the Effect of the Ambient Temperature on the Luminous Flux of Blub Type Flourescent Lamp, Department of Electrical Engineering, Yonsei University, 1989
  10. Gye Hyun Jo, Development of Hot Restarting Ignition Circuits to Expand HID Lamp Life, Department of Electrical Engineering, Kangwon National University, 2004
  11. Kyung Yul Kim, The Characteristic Evaluation of Thermal Fatigue for Tungsten Filament, Department of Mechanical Engineering, Kyung Hee University, 2002