참고문헌
- 김홍진, 김현배, 조지성, 이상현, 우성식, 최기영 (2006) LCVA를 이용한 초고층건물의 풍진동 제어성능 실험 평가, 대한건축학회 학술발표대회 논문집, 26(1), pp.13-16
- 김홍진, 김형섭, 민경원, 오정근 (2003) TMD와 TLCD의 지진응답에 대한 제어성능 평가 연구, 한국지진공학회논문집, 7(5), pp.85-91
- 손동인 (2001) 건축구조물에서 지진하중에 대한 점탄성 감쇠기의 최적 설계, 석사학위논문, 서울 대학교
- 이상현, 박은천, 윤경조, 이성경, 유은종, 민경원, 정란, 민정기, 김영찬 (2006) 실물 크기 구조물의 강제진동실험 및 지진응답 모사를 위한 HMD제어기 설계, 한국지진공학회논문집, 10(6), pp.103-114 https://doi.org/10.5000/EESK.2006.10.6.103
- Banerji, P., Murudi, M. Shah, A.H. Popplewell, N. (2000) Tuned liquid dampers for controlling earthquake response of structures, Earthquake engineering & structural dynamics, 29(5), pp.587-602 https://doi.org/10.1002/(SICI)1096-9845(200005)29:5<587::AID-EQE926>3.0.CO;2-I
- Den Hartog, J.P. (1956) Mechanical Vibrations, 4th edn, McCraw-Hill, New York
- Desu, N.B., Deb, S.K., Dutta, A. (2006) Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings, Structural control and health monitoring, 13(5), pp.897-916 https://doi.org/10.1002/stc.64
- Gao, H., Kwok, K.S.C., Samali, B. (1999) Characteristics of multiple tuned liquid column dampers in suppressing structural vibration, Engineering structures, 21(4), pp.316-331 https://doi.org/10.1016/S0141-0296(97)00183-1
- Haskett, T., Breukelman, B., Robinson, J., Kottelenberg J. Tuned Mass Dampers Under Excessive Structural Excitation, Response of structures to extreme loading (Conference), pp.37-43
- Kareem, A., Kijewski, T., Tamura, Y. Mitigation of Motions of Tall Buildings with Specific Examples of Recent Applications, Wind and Structures, 2(3), pp.201-251
- Li, C., Liu, Y. (2002) Active multiple tuned mass dampers for structures under the ground acceleration, Earthquake engineering & structural dynamics, 31(5), pp.1041-1052 https://doi.org/10.1002/eqe.136
- Lu, L.Y. (2004) Semi-active modal control for seismic structures with variable friction dampers, Engineering structures, 26(4), pp.437-454 https://doi.org/10.1016/j.engstruct.2003.10.012
- Mohammad, R.O., Mohammad, R., Amir, K.T. (2006) Tuned Mass Dmaper For Seismic Response Reduction of Tehran Tower, 4th International Conference on Earthquake Engineering, Taipei, Taiwan, Paper No.132
- Sakai, F., Takaeda S., Tamaki T. (1989) Tuned Liquid Column Damper-New Type Device for Suppression of Building Vibrations, Proc. Int Conf. on Hight Rise Building, Nanjing, China, pp.25-27
- Chang, K. C., Lai, M. L., Soong, T.T., Hao, D. S. (1993) Seismic Behavior and Design Guidelines for Steel Frame Structures with Added Viscoelastic Dampers, Technical Report NCEER-93-0009, National Center for Earthquake Engineering Research, Buffalo, NY
- Soong, T.T., Dargush, G.F. (1997) Passive Energy Dissipation Systems in Structural Engineering, New York, John Wiley & Sons
- Reiterer, M., Ziegler, F. (2005) Bi-axial Seismic Activation of Civil Engineering Structures Equipped with Tuned Liquid Column Dampers, JSEE, 7(1), pp.45-60
- Wright, G. (2002) Steadying Influence-Damper systems save millions in cost, while reducing lateral movement in tall buildings, Building Design & Constuction
- Ghosh, A., Basu, B. (2006) A closed-form optimal tuning criterion for TMD in damped structures, Structural control and health monitoring, 14, pp.681-692