A Methodology for Monitoring Prestressed Force of Bridges Using OFS-embedded Stand

광섬유센서가 내장된 강연선을 이용한 교량의 장력 모니터링 방법

  • 김재민 (전남대학교 건설.환경공학부) ;
  • 김현우 (전남대학교 건설.환경공학과) ;
  • 김영상 (전남대학교 건설.환경공학부) ;
  • 김진원 (전남대학교 건설.환경공학과) ;
  • 윤정방 (KAIST 건설 및 환경공학과)
  • Published : 2008.06.30

Abstract

This study proposes a novel method for in service evaluation of tension force of a prestressed 7-wire strand which is frequently employed for retrofitting bridge superstructure. The smart strand is made by replacing the straight king wire of the strand with an instrumented steel tube in which the FBG sensor is embedded. Since the strain of the smart strand can easily be measured using the sensor, it is possible to monitor tension force of the strand during the service. For the sake of demonstrating effectiveness of the proposed strand, we came up with a 7.0m long prototype with 2 FBG sensors, and it is applied as an external tendon to a 6.4m long and 0.6 high RC T-shaped beam. A loading-unloading test has been carried out, and estimated tension forces using the smart strand are compared with measured forces by load cell. The comparison showed that the proposed smart tendon is useful and accurate for monitering tension force of the prestressed tendon.

이 연구에서는 교량 상부구조물의 보수 보강에 많이 사용되는 7연 강연선의 공용중 긴장력 관리를 위한 새로운 방법은 제안하였다. 제안된 스마트 강연선은 기존 강연선의 중앙 킹와이어를 강제튜브로 대체하고, 강제튜브의 내부에 FBG 광섬유센서를 설치하여 강연선의 변형률을 측정할 수 있도록 하였다. 내장된 센서를 통하여 이 스마트 강연선의 변형률을 쉽게 측정할 수 있으므로, 공용중 강연선의 긴장력을 모니터링할 수 있다. 본 연구에서 제안된 장력 모니터링 방법의 효용성을 증명하기 위하여 FBG센서 2개가 내장된 길이 7.0m인 스마트 강연선을 제작하고, 이를 길이 6.4m, 높이 0.6m인 RC T형 모형거더에 외장형 텐던으로 적용하였다. 그리고 이 시험거더에 대한 재하-제하시험을 실시하고 로드셀에서 계측된 긴장력과 스마트 강연선을 이용하여 예측한 긴장력을 비교하였다. 비교 결과, 제안된 스마트 강연선은 긴장력이 작용된 강연선의 장력을 정확하게 모니터링 하는데 유용함을 확인할 수 있었다.

Keywords

References

  1. 구호본, 백용 (2001) 광섬유 센서를 이용한 산사태 계측기법 개발, 한국건설기술연구원
  2. 김기수 (2007) 광섬유센서를 이용한 사회기반시설 구조물의 스마트 모니터링 기법, 미래의 토목공학, 대한토목학회 자연과 문명의 조화, 55(4), pp.81-91
  3. 김정태, 홍동수, 박재형, 조현만 (2008) PSC 거더의 진동기 반 긴장력 손실 모니터링, 한국전산구조공학회 논문집, 21(1), pp.83-90
  4. 김재민, 김영상, 김현우, 서동남, 윤정방 (2007) FBG 센서 를 내장한 스마트 강연선 개발, 한국전산구조공학회 논문집, 20(2), pp.33-38
  5. 김현우, 김재민, 김진원, 김영상, 윤정방 (2008) 광섬유센서가 내장된 강연선을 이용한 교량의 장력 모니터링 방법, 한국전산구조공학회 논문집, Session6 Smart Structures, pp.133-138
  6. Calvert, S., Mooney, J. (2004) Bridge structural health monitoring system using fiber grating sensors: development and preparation for a permanent installation, SPIE Proceedings, 5391, pp.61-71
  7. Li, E., Xi, J., Chicharo, J., Liu, T., Li, X., Jiang, J., Li, L., Wang, Y., Zhang, Y. (2005) The experimental evaluation of FBG sensor for strain measurement of prestressed steel strand, SPIE Proceedings, 5649, pp.463-469
  8. Meltz, G. (1996) Overview of fiber grating based sensors, SPIE Proceedings, 2838, pp.2-22
  9. Nellen, P.M., Anderegg P., Bronnimann, R., Meier U., Sennhauser, U. (1999a) Fiber Optical Bragg Grating embedded in CFRP wires. SPIE Proceedings, 3870, pp.440-449
  10. Nellen, P.M., Bronnimann, R., Frank, A., Mauron, P., Sennhauser, U. (1999b) Structurally embedded fiber bragg gratings: civil engineering application, SPIE Proceedings, 3860, pp.44-54
  11. Ren, L., Li, N-H., Sun, L., Li, D-S. (2005) Development of tube-packaged FBG strain sensor and application in the vibration experiment of submarine pipeline model, SPIE Proceedings, 5770, pp.199-204
  12. Zhou, Z., Zhang, Z., Deng, N., Zhao, X., Li, D., Wang, C., Ou, J. (2005) Applications of FRP-OFBG sensors on bridge cables, SPIE Proceedings, 5765, pp.668-677
  13. Zhou, Z., Zhao, X., Wang, C., Zhang, Z., Hu, Q., Ou, J. (2004) A new kind of smart bridge cable based on FBG sensors, SPIE Proceedings, 5502, pp.196-199
  14. Zhou. Z., Thomas W.G., Luke Hsu, Ou J.P. (2003) Techniques of advanced FBG sensors : fabrication, demodulation, encapsulation and their application in the structural health monitoring of bridges, Pacific Science Review, 5, pp.116-121