The Korean Journal of Nuclear Medicine Technology (핵의학기술)
- Volume 12 Issue 1
- /
- Pages.91-98
- /
- 2008
- /
- 1229-9901(pISSN)
- /
- 2982-8406(eISSN)
A Study on the Effective Controlling System of Radio-activity Ventilation
RI사용 의료기관의 효율적인 배기관리 방안
- Lee, Kyung-Jae (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Lee, Jin-Hyung (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Kim, Kyung-Hoon (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Kwack, Dong-Woo (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Jo, Hyun-Duck (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Ko, Kil-Man (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Park, Young-Jae (Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
- Lee, In-Won (Department of Nuclear Medicine, Seoul National University Bundang Hospital)
- 이경재 (분당서울대학교병원 핵의학과) ;
- 이진형 (분당서울대학교병원 핵의학과) ;
- 김경훈 (분당서울대학교병원 핵의학과) ;
- 곽동우 (분당서울대학교병원 핵의학과) ;
- 조현덕 (분당서울대학교병원 핵의학과) ;
- 고길만 (분당서울대학교병원 핵의학과) ;
- 박영재 (분당서울대학교병원 핵의학과) ;
- 이인원 (분당서울대학교병원 핵의학과)
- Received : 2007.11.21
- Accepted : 2007.12.15
- Published : 2008.05.11
Abstract
Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.
산업의 발달과 기술개발을 통해 양적이나 질적으로 많은 성장을 해오고 있다. 특히 연구 개발 또는 진단용 방사성동위원소 사용 및 생산은 국내 사이클로트론 보급이 확대됨에 따라 그 성장추세가 급격하게 이루어지고 있다. 방사성동위원소를 취급하는 기관으로는 병원, 발전소, 연구소, 교육기관 등이며, 이러한 시설은 급기보다 배기시설을 중요시 하는데, 이러한 시설에서 발생되는 방사능 오염물질이 외부로 방출될 경우 주변 환경을 오염시키기 때문에 원자력법에 의하여 배기되는 공기 중 방사능 농도를 규제하고 있다. 본 과제에서는 현재 국내병원들의 배기관리 실태파악 및 현황을 설명하고 이러한 운영현황이 규제기관인 한국원자력 안전기술원의 원자력법에서 규정한 배출관리 기준을 만족하는지에 대해 알아보고 개선과제를 도출하여 기준안을 마련하여야 할 것이다. 필터의 정의 및 pre filter, hepa filter, charcol filter의 특징과 구조에 대해 알아보고 RI filter 교체 절차와 주의할 사항을 알아보았다. 규제기관인 한국원자력안전기술원의 원자력법에서 규정한 배출관리 기준 및 RI filter의 교체주기의 기준을 제시하겠고 국내 의료기관의 RI배기관리 실태파악 및 현황을 설명하고 이러한 운영현황의 장단점을 비교분석하여 기준안을 제시하였다. 분당서울대학교병원이 도입한 RCMS 기능 및 타 의료기관에서 사용 중에 있는 디지털 차압 게이지를 PC와 연동하여 구동하는 시스템을 제시하였다. RI를 사용하는 의료기관들의 의료시스템은 21세기를 맞아 눈부시게 개혁되고 있다. 특히 방사선안전관리 분야도 국제적 변화에 발맞추어 세분화, 고도화, 첨단화로 급격한 기술변화에 거듭나고 있다. 그러나 현재의 배기관리 시스템은 과거의 형태에서 변화를 찾아 볼 수 없다. 우선 우리나라의 발전된 정보통신 기술을 적극 활용하여 RCMS 및 디지털 차압게이지를 이용한 시스템 기능을 강화하여 RI filter의 교체주기와 배출관리 규정의 두 마리 토끼를 잡아야 할 것이다. 본 과제에서는 지금까지 배기관리 시스템을 현장에서 사용하는 방사선안전관리자로서 현재의 문제점 및 개선안에 대한 개인적인 제안사항을 제시하였다. 이러한 제안은 보다 심도 깊은 검토과정을 거쳐추진을 할 필요가 있다고 판단된다.