Suggestion of the Specific Infiltration Equation for Infiltration Trench Installed in a Granular Ground

조립토 지반에 설치된 침투트렌치의 비침투량 산정식 제안

  • Nam, Jung-Man (Dept. of Civil Engrg., Cheju National University) ;
  • Yun, Jung-Mann (Dept. of Civil Engrg., Ansan College of Technology) ;
  • Kim, Do-Hyeong (Civil Design Team, Dong-Ah Geolodical Engrg. CO., LTD.)
  • 남정만 (제주대학교 해양과학대학 토목공학과) ;
  • 윤중만 (안산공과대학 건설계열 건설전공) ;
  • 김도형 (동아지질 설계지원팀)
  • Received : 2008.11.17
  • Accepted : 2008.12.06
  • Published : 2008.12.30

Abstract

The model test and field test for an infiltration trench were carried out to estimate the infiltration quantity in a granular ground with high permeability like Jeju's ground. The specific infiltration equation was suggested on the basis of the model test result. It shows that the infiltration quantity by the proposed equation is larger than about two times of that by the existed equation. Meanwhile, the infiltration quantity from field test is similar to that from the proposed equation as the result of comparison between infiltration quantity of the filed test and that of the proposed equation and the existed equation. Therefore, it may be right that the proposed equation is applied to estimate the infiltration quantity of the infiltration trench in a granular ground with high permeability.

본 연구에서는 제주도와 같이 투수성이 매우 높은 지반에서의 침투량을 산정하기 위하여 침투트렌치에 대한 모형시험 및 현장시험을 실시하였다. 모형실험결과를 토대로 비침투량 산정식을 제안하였다. 제안된 식에 의해 산정된 침투량은 기존식에 의해 산정된 침투량보다 약 2배 정도 크게 나타났다. 한편, 현장침투시험을 통해 얻어진 침투량을 제안식과 기존식에 의해 얻은 침투량과 비교 한 결과, 현장침투시험을 통해 얻은 침투량은 제안식에 의해 얻은 침투량과 거의 비슷하게 나타났다. 따라서 투수성이 높은 조립토 지반에 설치된 침투트렌치의 침투량을 산정함에 있어 본 연구에서 제안된 침투량 산정식을 적용하는 것이 타당하다.

Keywords