Abstract

The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

Keywords

References

  1. http://www.yegeon.com/sub2_2e.htm
  2. 안태경, 전봉구, 이명호, " 자연형 태양열 직접획득방식에서의 야간 단열구조의 개발 및 열성능에 관한 연구"대한건축학회 추계학술발표대회 논문집(계획계)., V.8, No.2, 1988.10
  3. 김기세, 윤종호, 송인춘, "유리온실 적용 열반사 야간단열 시스템의에너지 성능평가 연구"., V.16, No.10, 2000.10
  4. 윤종호, 김병수 "투명단열 축열벽 시스템의 하절기 과열현상 방지에 관한 실험 연구", 대한건축학회 계획계논문집, Vol.19, 2003.11