DOI QR코드

DOI QR Code

Standardization of Temperature Measurement System for Stable and Reliable Infrared Thermographical Image

열화상 이미지의 신뢰성 확보를 위한 온도입력시스템의 표준화

  • Yoon, Se-Hyun (Dept. of Architectural Engineering, Dankook University) ;
  • Chung, Lan (Dept. of Architectural Engineering, Dankook University)
  • 윤세현 (단국대학교 건축공학과) ;
  • 정란 (단국대학교 건축공학과)
  • Published : 2008.12.31

Abstract

This study presents a technique to quantitatively measure the corrosion level of a reinforcing bar using infrared thermography system. We found out electric heating method having an important effect on thermal data in previous study. This study purposed an efficient way for grip standardization to reduce constriction resistance problem, and providing reliable thermal data using infrared thermographic method. Using vise type earth clamp, the surface resistance of rebar was smaller than that of traditional plier type earth clamp through temperature-distribution relationship. Also this study contains experiments with toque wrench to improve heating contact problem.

이 연구는 적외선 열화상을 이용하여 철근의 부식을 정량적으로 파악하는 기법을 개발하는 것이다. 연구 진행 과정에서 전기적 가열방법이 실험 데이터에 지대한 영향을 끼치는 것을 발견했다. 가열접촉 방법에 대한 여러 실험적 연구를 통하여 실험 데이터의 신뢰성 확보와 효율적인 연구를 추구하였다. 사각어스클램프를 이용하여 철근을 가열하였을 때 철근의 온도변화를 통해 집게어스클램프보다 표면저항이 적다는 것을 입증하였다. 또한 접촉 방법의 표준화를 위해 토크렌치를 활용한 실험을 진행하였다.

Keywords

References

  1. 대한건축학회, 신도시 아파트 내구성 조사연구 보고서, 1995, pp. 20-52
  2. 오병환, 차수원, 조윤구, 구조물의 염해 대책 특별 연구 보고서, 서울대 공학 연구소, 1995, pp. 5-35
  3. 백인관, 정란, 조승호, '적외선 열화상 데이터를 이용한 철근 부식률 비파괴 측정기법,' 건축, 21권, 8호, 2005, pp. 3-10
  4. 박현수, 정란, 노영숙, '디지털 화상정보를 이용한 매입 철근의 부식률 예측모델,' 비파괴검사학회지, 24권, 7호, 2008, pp. 77-84
  5. 박문호, 이익환, '적외선을 이용한 비파괴검사 기술,' 비파괴검사학회지, 1994, pp. 77-84
  6. Maser, K. R. and Kim, Roddis W. M., 'Principles of Thermography and Radar for Bridge Deck Assessment,' Journal of Transportation Engineering, Vol. 116, No. 5, 1990, pp. 583-601 https://doi.org/10.1061/(ASCE)0733-947X(1990)116:5(583)
  7. Nagataki, S., Kamada T., and Matsumoto, A., 'Application of Infrared Thermography Technique for Evaluation of Cracks in the Concrete Structures,' Special Publication of ASCE, June 1998, pp. 198-203
  8. Kwan, H., A Study on the Practical Use for Detection of Default in Reinforced Concrete Structure with a Thermographic Survey Applied, Ph.D. Dissertation, YeungNam University, 2000, pp. 52-59
  9. Spicer, J. W. M., Wilson, D. W., Osiander, R., and Thomas, J., Oni B.O., 'Evaluation of High Thermal Conductivity Graphite Fibers for Thermal Management in Electronics Applications,' in Thermosense XXI, Proc. SPIE, R.N. Wurzbach, D.D. Burleigh Eds., 3700, 1999, pp. 40-47
  10. Del Grande, N. K. and Durbin, P. F., 'Dual-Band Infrared Imaging to Detect Corrosion Damage Within Airframes and Concrete Structures,' Proc. SPIE, International Conference on Thermal Sensing and Imaging and Diagnostic Applications, Orlando, Florida, April 4-8, 1994, pp. 1632-1639
  11. Clemena, G. G. and McKeel, W. T., 'Detection of Delamination in Bridge Decks with Infrared Thermography,' Transportation Research Record, No. 664, 1978, pp. 155-175
  12. Mickenizie, S. G., 'Techniques for Monitoring Corrosion of Steel in Concrete,' Corrosion Prevention & Control, Vol. 34, No. 1, 1987, pp. 78-95
  13. 백인관, 적외선 열화상법을 이용한 철근부식률 비파괴 측정기법개발에 관한 연구, 단국대학교 박사학위논문, 2006, pp. 75-101