Abstract
DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).
서인천 복합 화력발전소의 GE 7FA+e DLN-2.6 가스터빈 연소기 튜닝을 실시하였다. DLN-2.6 연소기는 기동초기 저출력 조건에서 yellow plume 현상과 정상상태보다 높은 수준의 연소진동이 발생하는 문제점이 있었다. 본 논문의 목적은 기동초기의 yellow plume과 연소진동의 발생 원인을 규명하여 실 연소기를 안정적으로 운용할 수 있는 최적의 운전 조건을 제시하는 것이다. 실연소기 튜닝과정을 통해 얻은 자료를 분석한 결과 기동초기 모드 3($20{\sim}30MW$)에서 PM 1 노즐에서의 과농한 혼합기(${\phi}{\sim}1$)에 의해 yellow plume이 생성되었다. 모드 6B($40{\sim}45MW$)에서의 연소진동 발생은 $120{\sim}140Hz$ 부근에서 생성되었고 연소기 온도에 영향을 받지 않는 cold flow 특성으로 보이며 PM 3 노즐에서의 유량과 관련이 있었다.