Lots of products stocked at a traditional market are made of rubbers, synthetic fibers and plastics which when on fire, emit high heat to easily ignite nearby inflammables. And shops are not divided by fireproof partitions but by combustible curtains, which contributes to a possibility of a conflagration. In this study, danger and weak factors on fire at a traditional market was analyzed. Non-existence of partition between shops and the height of piled inflammables are set as danger factors and change of extinguishing capacity of sprinklers was analyzed using fire dynamics simulator. As a result, it turned out that partitions between shops and high-piled inflammables reduced watering radius of sprinklers and increased the size of fire and distribution of temperature.

소규모 점포가 밀집한 재래시장에 적재된 물품은 고무, 합성섬유제품, 플라스틱 등으로 대부분이 화재발생시 높은 열량을 방출하여 인접 가연물에 쉽게 착화되는 경향이 있다. 또한 점포간에 방화구획이 마련되지 않고 커튼과 같은 가연성물질로 구획되어 화재가 대형화될 수 있는 실정이다. 따라서 낙후된 재래시장의 화재위험성, 취약요인을 분석하고 화재발생시 가장위험하다고 판단되는 점포칸막이의 유무 가연물의 적재 높이 등을 화재 시 위험요소로 설정하여 Field 모델링이 가능한 화재시뮬레이션을 활용하여 스프링클러설비의 소화성능변화와 화재특성을 분석하였다. 그 결과 점포칸막이, 가연물의 적재높이 등은 스프링클러 살수반경에 장애요인으로 작용하여 화재의 크기 및 온도분포를 증가시키는 요인으로 나타났다.

Keywords

References

  1. 박동균, "다중이용시설 화재 사례를 통해 본 위기관 리의 실패와 함의", 도시행정학보, Vol.19, No.1, pp.201-217(2006)
  2. "2005년화재통계연감", 소방방재청(2005)
  3. "대구 중구 서문시장 화재사고 종합결과보고", 대구 소방본부(2005)
  4. "서문시장화재사고 현지조사 결과보고", 소방방재청 (2006)
  5. 김태형, "자동 스프링클러 시스템의 신뢰성에 대한 조사 연구", 서울시립대학교 석사학위논문(2006)
  6. 김흥식, "화재사례를 통하여 고찰한 재래시장 소방안 전에 관한 연구", 서울시립대학교 석사학위논문(2006)
  7. "서문시장 2지구 화재에 따른 특별조사결과보고", 대구 중부소방서(2006)
  8. 박진우, 이민호, 전규엽, 홍원화, "국내재래시장의 화 재안전의 문제점에 대한 사례 연구", 한국화재소방학 회 춘계학술논문발표회논문집, pp.182-186(2006)
  9. K.B. McGrattan, "Fire Dynamics Simulator (Version 4.1) - User's Guide", NIST(2002)