Abstract

This paper studied on the causal analysis of electrical fire by using fuse that it is used with safety device in electrical products. The experimental samples used are glass tube fuse(15 A, $5{\times}20mm$) and temperature fuse(10 A, $72^{\circ}C$). The experiment analyzed on the characteristics of damaged fuse by main causes(short circuit, overload, external flame) of electrical fire. The results showed, in case of glass tube fuse identified different characteristics in external form and element surface and element texture of damaged fuse by main causes of electrical fire. In case of temperature fuse identified different characteristics in external form and sliding contact surface and sliding contact texture of damaged fuse only by external flame.

본 논문은 전기제품 내에 안전장치로 사용되는 퓨즈를 이용한 전기화재의 원인분석에 관한 연구이다. 시료는 유리관퓨즈(정격 15 A, $5{\times}20mm$)와 온도퓨즈(정격 10 A, $72^{\circ}C$)를 사용하였다. 전기화재의 주요원인인 단락 및 과부하 그리고 외부화염을 인위적으로 가하여 소손된 퓨즈의 특성을 비교 분석하였다. 실험결과 유리관퓨즈의 경우 소손된 퓨즈의 외형 및 표면 그리고 조직분석에서 서로 다른 특징들을 확인할 수 있었다. 온도퓨즈의 경우 외부화염실험의 경우에서만 소손된 퓨즈의 외형 및 가동접점의 표면 그리고 조직분석에서 뚜렷한 특징이 나타났다.

Keywords

References

  1. 최충석, 김현우, 이경섭, 이춘하, 임양수, 정재희, "전기화재공학", 동화기술, pp.189-237(2004)
  2. 인천소방본부 화재조사팀, "현장실무자를 위한 화재 원인 조사기법", pp.263-268(2003)
  3. 김두현, 김응식, 김상철, 김찬오, 윤양배, 이동훈, 이 성일, 정재희, 조성곤, "최신전기안전공학", 신광문화사, pp.237-248(2004)
  4. 소방방재청, "2007년도 전국 화재 발생현황 분석 결과"(2008)
  5. 김만건, 김진표, "전기화재 감식공학", 성안당, pp.51- 56(2006)
  6. 최충석, "전기화재의 종류 및 원인분석", 전기저널 (2001. 12)
  7. 洪世基, "電氣火災 原因分析 및 豫防對策 硏究", 韓國 電氣安全公社(1994)
  8. 한국전기안전공사 신기술법제팀, "전기설비기술기준 및 판단기준"(2007. 1)
  9. 최충석, "열적 스트레스 변화에 따른 600 V 비닐절연 전선의 특성분석", 한국화재소방학회논문지, Vol.15, No.1, pp.108-115(2001)