DOI QR코드

DOI QR Code

비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석

Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System

  • 발행 : 2008.05.01

초록

Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.

키워드

참고문헌

  1. Kim, J. S., 2001, “TFT-LCD Summary and Development Research Trend,” Journal of the KSME, Vol. 41, No. 5, pp. 37-41
  2. Huh, J. S., 2006, "A Study on the Robust Optimal Supporting Positions of TFT-LCD Glass Panel," Transactions of the KSME, Vol. 30, No. 8, pp 1001-1007 https://doi.org/10.3795/KSME-A.2006.30.8.1001
  3. Kim, S. W., Beck, D. S., Kim, S. D. and Kim W. S., 2003, "Development of a FPD Stocker GUI," Transactions of Semiconductor Equipment Technique, Vol. 2000, pp. 31-37
  4. Choi, G. H., Han, C. W. and Lee, S. R., 2002, "The Study on the Development of Composite Robot Hand for TFT-LCD Glass Transport," Transactions of the KSME, Vol. 26, No. 7, pp. 1357-1365 https://doi.org/10.3795/KSME-A.2002.26.7.1357
  5. Oh, J. H. and Lee, D. G., 1999, "Composite Robot End Effector for Manipulating Large LCD Glass Panels," Composite Structures, Vol. 47, pp. 497-506 https://doi.org/10.1016/S0263-8223(00)00013-1
  6. Tak, T. O., Kim, H. Y., Chun, H. H and Oh, Y. B., 2004, "Vibration Attenuation Study for An LCD Pannel Handling Robot," Journal of Industrial Technology, Vol. 24, No. B, pp. 73-81
  7. Lee, J. G. and Choi, S. S., 2004, "The study of impact analysis of TFT-LCD module," Transactions of the KSME, Vol. 28, No. 5, pp. 571-577 https://doi.org/10.3795/KSME-A.2004.28.5.571
  8. Park, S. J., Kim, M. S., Kim, J. S. and Joo, H. N., 2005, "A Study on the Design of Vision Inspection System for FPD Defects Detection," The Journal of Research Institute for Engineering & Technology, Vol. 24, pp. 123-136
  9. Kim, M. H., Yoon, J. H., Lee, T. Y. and Lee, S. R., 2006, "Development of Inference Technique for Non-uniformity of ITO coated Glass using Neuro-Fuzzy Method," Proceedings of the KSME 2006 fall Annual Meeting, pp. 67-71
  10. Jung, H. S., Lee, S. M., Hong, M. S., Lee, S. H., Park, J. H., Kang, D. W. and Lee, M. G., 2007, "A novel stylus profiler without nonlinearity and parasitic motion for FPD inspection system," Journal of Mechanical Science and Technology, Vol. 21, No. 10, pp. 1491-1497 https://doi.org/10.1007/BF03177364
  11. Park, K. D., Lee, J. K., Ha, M. Y., Park, B. E., Oh, W. T. and Kim, G. J., 1996, "Contaminant Analysis in TFT-LCD Photolithography Process," Proceedings of the KSME 1996 Fall Annual Meeting, No. 2, pp. 402-407
  12. Seo, M. S., Kim, M. and Kim, H., 2005, "Study of Design Parameters for Semiconductor/FPD Cleanroom Focused on Airborne Contamination," Key Engineering Materials, Vol. 2005, pp. 277-279

피인용 문헌

  1. Design optimization of conveyor rollers arrangement for stable flat-panel display (FPD) glass transfer vol.32, pp.7, 2018, https://doi.org/10.1007/s12206-018-0626-6