서울.경기 일부지역 다중이용시설실내공기 중 미세먼지와 미세먼지 중 내독소의 농도

Indoor Air Concentration of Particulate Matter and Endotoxin in Public Facilities

  • 전병학 (가톨릭대학교 의과대학 예방의학교실) ;
  • 황유경 (가톨릭대학교 의과대학 예방의학교실) ;
  • 김형아 (가톨릭대학교 의과대학 예방의학교실) ;
  • 이세훈 (가톨릭대학교 의과대학 예방의학교실) ;
  • 안규동 (순천향대학교 의과대학 예방의학교실) ;
  • 허용 (대구가톨릭대학교 자연대학 산업보건학과)
  • Jeon, Byung-Hak (The Catholic University of Korea, Dept. of Prev. Med) ;
  • Hwang, Yu-Kyung (The Catholic University of Korea, Dept. of Prev. Med) ;
  • Kim, Hyoung-Ah (The Catholic University of Korea, Dept. of Prev. Med) ;
  • Lee, Se-Hoon (The Catholic University of Korea, Dept. of Prev. Med) ;
  • Ahn, Kyu-Dong (Soonchunhyang University, Dept. of Prev. Med) ;
  • Heo, Yong (Catholic University of Daegu, Dept. of Occupational Health)
  • 투고 : 2008.07.29
  • 심사 : 2008.10.24
  • 발행 : 2008.12.31

초록

This study was conducted to measure concentrations of particulate matter ($PM_{10}$, $PM_{2.5}$) and endotoxin in thirty public facilities (7 elderly-care facilities, 4 hypermarkets, 4 university hospitals, 7 child-care facilities, 4 subway stations and 4 bus terminals) from September 2004 to February 2007 in Seoul and Gyeonggi-do province. $PM_{10}$ or $PM_{2.5}$ was measured with glass fiber filter and mini volume air sampler for 6 to 8 hours in indoor and outdoor of the facilities and expressed as ${\mu}g/m^3$. After weighing the filter, endotoxin was analyzed by Limulus Ameobocyte Lysate method ($EU/m^3$). $PM_{10}$ in indoor air was higher (GM and GSD was 78.00 and $1.92\;{\mu}g/m^3$, respectively) than the outdoor air (GM and GSD was 60.70 and $2.23\;{\mu}g/m^3$, respectively, I/O=1.28). All measurements was not exceeded the national maintenance standard. Elderly-care and child-care facilities showed relatively higher concentrations ($83.27\;{\mu}g/m^3$ and $81.75\;{\mu}g/m^3$; I/O=2.01 and 1.19, respectively) than hypermarkets or university hospitals. The highest PM2.5 was seen in child-care facilities ($62.15\;{\mu}g/m^3$, I/O=2.42). The I/O of the endotoxin in the PM10 and the $PM_{2.5}$ was exceeded 1.0 (1.37 and 1.57, respectively). Indoor $PM_{10}$ was affected by user/day and humidity, and endotoxin in the PM10 was affected by temperature. In conclusion, elderly- and child-care facilities are high priority facilities to be improved indoor air quality.

키워드

과제정보

연구 과제 주관 기관 : 한국과학재단

참고문헌

  1. 문경환, 변상훈, 최달웅, 김영환, 이장희 등. 알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로. 한국환경보건학회지 2005;31(2):120-126
  2. 환경부. 다중이용시설등의 실내공기질관리법. 환경부 2004a
  3. 환경부. 실내공기질 공정시험방법. 환경부 2004b
  4. Abbey DE, Hwang BL, Burchette RJ et al. Estimated long-term ambient concentrations of PM10 and development of respiratory symptoms in a nonsmoking population. Arch Environ Health 1995;50:139-151 https://doi.org/10.1080/00039896.1995.9940891
  5. Abt E, Suh HH, Allen G, Koutrakis P. Characterization of indoor particle sources: A study conducted in the metropolitan Boston area. Environ Health Perspect 2000;108:35-44 https://doi.org/10.2307/3454293
  6. ACGIH. Bioaerosols Assessment and Control. ACGIH 1999
  7. Battarbee JL, Rose NL, Long X. A continuous, high resolution record of urban airborne particulates suitable for retrospective microscopical analysis. Atmospheric Environment 1997;31(2):171-181 https://doi.org/10.1016/1352-2310(96)00195-1
  8. Burrel R, Ye S-H. Toxic risks from inhalation of bacterial endotoxin. Brit J Ind Med 1990;47:688-691
  9. Dales RE, Zwanenburg H, Burnett R, Freanklin CA. Respiratory health effects of home dampness and molds among Canadian children. Am J Epidemol 1991;134(2):196-203 https://doi.org/10.1093/oxfordjournals.aje.a116072
  10. Dockery DW, Schwartz J, Spengler JD. Air pollution and dairy mortality: associations with particulates and acid aerosols. Environ Res 1992;59:362-363 https://doi.org/10.1016/S0013-9351(05)80042-8
  11. Donham KJ, Haglind P, Peterson Y et al. Environmental and health studies of farm workers in Swedish swine confinement buildings. Br J Ind Med 1989;46:31-37
  12. EPA. Total Exposure Assessment Methodology (TEAM) Study. EPA 600/S6-87/002 U.S. 1987
  13. Euler GL, Abbey DE, Hodgkin IF et al. Chronic obstructive pulmonary disease symptom effects of long-term cumulative exposure to ambient levels of total suspended particulates and nitrogen dioxide in California Seventh-Day Adventist residents. Arch Environ Health 1988;43:279-285 https://doi.org/10.1080/00039896.1988.10545950
  14. Euler GL, Abbey DE, Magie AR et al. Chronic obstructive pulmonary disease symptom effects of long-term cumulative exposure to ambient levels of total suspended particulates and sulfur dioxide in California Seventh-Day Adventist residents. Arch Environ Health 1987;42:213-222
  15. Gordon T, Galdanes K, Brosseau L. Comparison of sampling media for endotoxin- contaminated aerosols. Appl Occup Environ Hyg 1992;7:472-477 https://doi.org/10.1080/1047322X.1992.10390192
  16. Huang HY, Haghighat F. Modeling of volatile organic compounds emission from dry building materials. Building and Environment 2002;37:1349-1360 https://doi.org/10.1016/S0360-1323(01)00116-0
  17. Katsouyanni K, Zmirou D, Spix C et al. Short-term effects of air pollution on health: a European approach using epidemiological time-series data. Europ Respir 1995; 8:1030-1038
  18. Kelly TJ, Smith DL, Satola J. Emission rates of formaldehyde from materials and consumer products found in California homes. Environ Sci Tech 1999;33:81-88 https://doi.org/10.1021/es980592+
  19. Kim S-M, Kim H-J. Comparison of formaldehyde emission from building finishing materials at various temperature in under heating system; ONDOL. Indoor Air 2005; 15:317-325 https://doi.org/10.1111/j.1600-0668.2005.00368.x
  20. Li C-S. Relationships of indoor/outdoor inhalable and respirable particles in domestic environments. Sci Total Environ 1994;151(3):205-211 https://doi.org/10.1016/0048-9697(94)90469-3
  21. Michel O, Kips J, Duchateau J et al. Severity of asthma is related to endotoxin in house dust. Am J Respir Crit Care Med 1996;154:1641-1646 https://doi.org/10.1164/ajrccm.154.6.8970348
  22. Osman LM, Douglas JG et al. Indoor air quality in homes of patients with chronic obstructive pulmonary disease. Am J Resp Crit Care Med 2007;176(5):465- 471 https://doi.org/10.1164/rccm.200605-589OC
  23. Park JH, Gold DR, Spigelman DL, Burge HA, Milton DK. House dust endotoxin and wheeze in the first year of life. Am J Respir Crit Care Med 2001;163:322-328 https://doi.org/10.1164/ajrccm.163.2.2002088
  24. Pluschke P Ed. Indoor Air Pollution. 4.F The Handbook of Environmental Chemistry. Springer, 2004
  25. Pope CA, Burnett RT, Thun MJ et al. Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution. J Am Med Assoc 2002; 287(9):1132-1141 https://doi.org/10.1001/jama.287.9.1132
  26. Pope CA, Dockery DW. Acute health-effects of PM10 pollution on symptomatic and asymptomatic children. Am Rev Respir Dis 1992;145:1123-1128 https://doi.org/10.1164/ajrccm/145.5.1123
  27. Pope CA, Dockery DW, Spengler JD et al. Respiratory health and PM10 pollution-a daily tome-series analysis. Am Rev Respir Dis 1991;144:668-674 https://doi.org/10.1164/ajrccm/144.3_Pt_1.668
  28. Schwartz J. Air pollution and hospital admissions for the elderly in Detroit, Michigan. Am J Respir Crit Care Med 1994a;150:648- 655 https://doi.org/10.1164/ajrccm.150.3.8087333
  29. Schwartz J. PM10, ozone and hospital admissions for the elderly in Minneapolis-St. Paul, Minnesota. Arch Environ Health 1994b;49:366-374 https://doi.org/10.1080/00039896.1994.9954989
  30. Seitz, TA . NIOSH Indoor Air Quality Investigations 1971-1988. In: The Practitioners Approach to Indoor Air Quality Investigations. Proc. Indoor Air Quality International Symposium. Weedes, D.M., Gammage, R.B., eds. American Industrial Hygiene Association, Akron, Ohio. 1989:163-171
  31. Smid T, Heederik D, Houba R et al. Dust- and endotoxin-related respiratory effects in the animal feed industry. Am Rev Respir Dis 1992;146:1474-1479 https://doi.org/10.1164/ajrccm/146.6.1474
  32. Spengler JD, Sexton K. Indoor air pollution : a public health perspective. Science 1983;221(4605):9-17 https://doi.org/10.1126/science.6857273
  33. Tokiwa H, Nakanishi Y, Sera N, Hara N, Inuzuka S. Analysis of environmental carcinogens associated with the incidence of lung cancer. Toxicol Lett 1998;99(1):33-41 https://doi.org/10.1016/S0378-4274(98)00136-2
  34. White EM. Environmental endotoxin measurement methods: Standardization issues. Appl Occup Environ Hyg 2002;17(9):606-609 https://doi.org/10.1080/10473220290095916
  35. Wood JE. An Engineering approach to controlling indoor air quality. Environ Health Perspect 1991;95:15-21 https://doi.org/10.2307/3431100
  36. Zock JP, Hollander A, Heederik D, Douwes J. Acute lung function changes and low endotoxin exposures in the potato processing industry. Am J Ind Med 1998;33:384-391 https://doi.org/10.1002/(SICI)1097-0274(199804)33:4<384::AID-AJIM9>3.0.CO;2-U