Most connections for the glulam structural members consisted of connector and fastener. The mechanical behaviour of the connection can be occurred by the dowel bearing resistance and wood shear by the fastener. This study aims at the examination of the shear properties for the small specimen with lamination components and for the full-sized pin connection and the moment resisting property for the double shear full-sized pin connection using structural column and beam members. Small specimens including glue line shows greater density and shear strength by the lamination effect than other specimens. It is needed that estimations of double shear property and moment resistance for the pin connections should be adjusted in some degree. For the better and safe estimation of moment resistance strength for the column-beam pin connection, however, the shear strength of small specimens should be deducted by 10%.
집성재의 구조부재로서의 이용에 있어서는 접합철물(connector)과 파스너(fastener)에 의한 접합이 대부분을 차지하고 있다. 이들 접합부의 역학적 거동은 파스너의 지압과 부재의 전단현상으로 설명할 수 있다. 집성재 내의 층재 구성상태에 따른 전단성능, 2면전단 핀접합부의 인발에 의한 전단성능, 실대 기둥-보 2면전단 핀접합부의 모멘트 저항성능을 검토하였다. 집성접착된 부위의 경우, 두 층재간의 보완작용에 의해 밀도 및 전단강도에 있어서도 적층효과를 발휘하였다. 소시험편의 전단강도를 이용한 핀접합부의 2면전단강도와 모멘트 저항성능을 예측할 경우 다소의 보정이 필요할 것으로 판단되었다. 기둥-보 접합부의 모멘트저항성능 예측은 소시험편 전단강도의 10%를 저감하여 이용하면 안전하게 예측가능한 것으로 판명되었다.