This paper presents an active vibration control of cantilever beams under disturbances by a primary force. A direct velocity feedback control using a pair of PZT actuator and a velocity sensor is considered. Variation of the stability and performance with the locations of the sensor/actuator pair is investigated. It is found that the maximum gain varies with the locations of the sensor/actuator pair significantly. The maximum gain shows a symmetric distribution along the beam length with respect to the center point, although the boundary condition of the beam is unsymmetric. The control performance is affected by the location of the primary force as well as the location of the sensor/actuator pair. The active control system can more effectively reduce the vibration when the primary force is located close to the fixed boundary.

키워드

참고문헌

  1. Akesson, H., Smirnova, T., Hakansson, L., Claesson, I. and Lago, T., 2008, 'Developments Steps of an Active Boring Bar for Industrial Application,' Inter-Noise 2008, Shanghai, China, Paper No. IN08-0631
  2. Qiua, Z.-C., Zhanga, X.-M., Wub, H.-X. and Zhangb, H.-H., 2007, 'Optimal Placement and Active Vibration Control for Piezoelectric Smart Flexible Cantilever Plate,' Journal of Sound and Vibration, No. 301, pp. 521-543
  3. Cai, G., et. al., 2004, 'Modal Study and Active Control of a Rotating Flexible Cantilever Beam,' International Journal of Mechanical Sciences, Vol. 46, No. 6, pp. 871-889 https://doi.org/10.1016/j.ijmecsci.2004.06.001
  4. Oh, J. E., Shin, J., Park, S. H., Kim, H. S., Hong, J. S., 1996, 'Active Vibration Control of Flexible Cantilver Beam Using Filtered-X LMS Algorithm,' KSME, Paper No. 96F353
  5. S. O. Reza Moheimani, Dunant Halim, Andrew J. Feming, 2003, 'Spatial Control of Vibration Theory and Experiments,' World Scientific
  6. Hong, C. S., 2005, 'Active Control of Resilientlymounted Flexible Structures,' Ph.D Thesis, Institute of Sound and Vibration Research, University of Southampton
  7. Hong, C. S., 2006, 'Multichannel Active Control of Honeycomb Trim Pannels for Aircrafts,' Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 16, No. 12, pp. 1252-1253 https://doi.org/10.5050/KSNVN.2006.16.12.1252
  8. Lee, Y.-S., 2004, 'Active Vibration Control of a Beam Using Direct Velocity Feedback,' Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 14, No. 7, pp. 619-625 https://doi.org/10.5050/KSNVN.2004.14.7.619
  9. Lee, Y.-S., 2004, 'Collocation of Sensor and Actuator for Active Control of Sound Vibration,' Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 14, No. 3, pp. 253-263 https://doi.org/10.5050/KSNVN.2004.14.3.253
  10. Lee, Y.-S., 2005, 'Comparison of Centralized and Decentralized Control for Vibration Suppression of a Beam,' Proceedings of the KSNVE Annual Autumn Conference, pp. 494-497
  11. Hong, C. S., 2005, 'Active Control of Resiliently-mounted Beams with a Moment Pair Actuator,' Smart Materials and Structures, Vol. 14, pp. 727-738 https://doi.org/10.1088/0964-1726/14/4/031
  12. Dosch, J., et. al., 1992, 'A Self Sensing Piezoelectric Actuator for Collocated Control,' Journal of Intelligent Material Systems and Structures, Vol. 3, pp. 155-185
  13. Lee, Y.-S., 2001, 'Distributed Four-layer PVDF Actuator/Sensor Arrangement for the Control of Beam Motion,' The International Society for Optical Engineering, Vol. 4326
  14. Blevins, R. D., 1979, Formulas for Natural Frequency and Mode Shapes, Krieger

피인용 문헌

  1. Performance of Active Vibration Isolation for Equipments on Flexible Beam Structures Using Wiener Filters vol.28, pp.5, 2018, https://doi.org/10.5050/KSNVE.2018.28.5.518
  2. Analysis for active isolation of the equipment on flexible beam structure vol.1075, pp.1742-6596, 2018, https://doi.org/10.1088/1742-6596/1075/1/012029