References
- Branemark PI, Hansson BO, Adell R et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Almquist and Wiksell International 1977
- Levine RA, Clem DS, Wilson TG et al. Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for two or more years. Int J Oral Maxillofac Implants 1999;14:516-520
- Lekholm U, Van Steenberghe D, Herrmann I et al. Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5year muticenter study. Int J Oral Maxillofac Implants 1994;9:627-635
- Buser D, Mericsek Stern R, Bernard JP et al. Long-term evaluation of non-submerged ITI implants. Part 1 : 8-year life table analysis of a prospctive multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-172 https://doi.org/10.1034/j.1600-0501.1997.080302.x
- Tolman DE, Laney WR. Tissue-integrated prothesis complications. Int J Oral Maxillofac Implants 1992;7:477-484
- Balshi TJ. An analysis and management of fractured implants: A clinical report. Int J Oral Maxillofac Implants 1996;11:660-666
- Ragnar A, Eriksson B, Lekholm U et al. A long-term follow up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;14:210-216
- Eliades T. Passive film growth on titanium alloys: Physico-chemical and biological consideration. Int J Oral Maxillofac Implants 1997;12:621-627
- Pan J, Thierry D, Leygraf C. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application. Elcetrochim Acta 1996;41:1143-1153 https://doi.org/10.1016/0013-4686(95)00465-3
-
Wennerberg A, Albrektsson, Lausmaa J. Torque and histomorphometric and removal torque study of screw-shaped titanium implants and 75um sized particles of
$Al_2O_3$ . Journal of Biomedical Materials Research 1996;30:251-260 https://doi.org/10.1002/(SICI)1097-4636(199602)30:2<251::AID-JBM16>3.0.CO;2-P - Buser D, Schenk R, Steinemann S et al. Influence of surface characteristics on bone integration of titanium implants. A histomorpho-metric study in miniature pigs. Journal of Biomedical Materials Research 1991;25:889-902 https://doi.org/10.1002/jbm.820250708
- Grook K, Geesink R, Klein C, Serekian P. Plasma sprayed coating of hydroxyapatite. Journal of Biomedical Materials Research 1987;21:1375-1381 https://doi.org/10.1002/jbm.820211203
- Rasmussen L, Meredith N, Sennerby L. Measurements of stability changes of titanium implants with exposed threads subject to barrier membrane induced bone augmentation. An experimental study in the rabbit tibia. Clin Oral Implants Res 1997;8:316-322 https://doi.org/10.1034/j.1600-0501.1997.080410.x
- Da Cunha HA, Francischone CE, Filho DE, Oliveira RCG. A comparison between cutting torque and resonance frequency in the assessment of primary stability final torque capacity of standard and TiUnite single tooth implants under immediate loading. Int J Oral Maxillofac Implants 2004;19:578-585
- Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2004;19:578-585
- Branemark PI, Hansson BO, Adell R et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977;111(Suppl 16):1-132
- Sennerby L, Meredith N. Resonance frequency analysis: Measuring implant stability and osseointegration. Compend Contin Educ Dent 1998;18:493-502
- Rasmusson L, Stegersjo G, Kahnberg K-E, Sennerby L. Implant stability measurements using resonance frequency analysis in the grafted maxilla: a cross-sectional pilot study. Clin Oral Dent Relat Res 1999;1:70-74 https://doi.org/10.1111/j.1708-8208.1999.tb00094.x
- Steigenga JT, Al-Shammari K, Nociti FH, Misch CE, Want HL. Dental implant design and its relationship to long-term implant success. Implant Dent 2003;12:306-317 https://doi.org/10.1097/01.ID.0000091140.76130.A1
- Trico J, van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: an in vitro study. J Prosthet Dent 1995;74:608-612 https://doi.org/10.1016/S0022-3913(05)80313-0
- Faulkner MG, Giannitsios D, Liipsett AW, Wolfarrdt JF. The use and abuse of the periotest for 2-piece implant/abutment systems. Int J Oral Maxillofac Implants 2001;16:486-494
- Becker W, Sennerby L, Bedrossian E, Becker BE, Lucchini JP. Implant stability measurements for implant placed at the time of extraction: a cohort, prospective clinical study. J Periodontal 2005;76:391-397 https://doi.org/10.1902/jop.2005.76.3.391
- Zix J, Kessler-Liechti G, Merickse-Stern R. Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Implants 2005;20:747-752
- Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-267 https://doi.org/10.1034/j.1600-0501.1996.070308.x
- Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng 1998;26:275-391 https://doi.org/10.1615/CritRevBiomedEng.v26.i4.20
- Schwarz MS, Rothman SLG, Rhodes ML, Chafetz N. Computed tomography: PartI. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants. 1987;2:137-141
- Schwarz MS, Rothman SLG, Rhodes ML, Chafetz N. Computed tomography: Part II. Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants 1987;2:137-141
- Fanuscu MI, Chang TL. Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible. Clin Oral Implants Res 2004;15: 213-218 https://doi.org/10.1111/j.1600-0501.2004.00969.x
- Hanazawa T, Sano T, Seki K, Okano T. Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images. Clin Oral Implants Res 2004;15:226-232 https://doi.org/10.1111/j.1600-0501.2004.00991.x
- Homolka P, Beer A, Birkfellner W, Nowotny R et al. Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 2002;224:247-252 https://doi.org/10.1148/radiol.2241010948
- Homolka P, Beer A, Birkfellner W et al. Local calibrated bone mineral density in the mandible presented using a color coding scheme. Med Eng Phys 2001;23:673 https://doi.org/10.1016/S1350-4533(01)00097-2