DOI QR코드

DOI QR Code

Performance Tests and Development of the Cyclic Load Device Using a Bellows

벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험

  • Published : 2007.09.01

Abstract

A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8mm in diameter and 12.5mm in gage length is also performed under the same conditions as the temperature($550^{\circ}C$) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles(about 12 days), and the displacement in this case is 2.02 mm. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.

Keywords

References

  1. Kim, B.G. et al., 2005, 'Capsule Development and Utilization for Material Irradiation Tests (Interim Report of Phase III),' KAERI/TR-3013/2005, KAERI
  2. Cho, M.S. et al., 2005, 'The Irradiation Test Results of the Creep Capsule (02S-08K),' KAERI/TR-2990/2005, KAERI
  3. Choi, Y., Cho, M.S., Kim, B.G. and Kang, Y.H., 2005, 'Multi-Channel Mechanical Test Machine for HANARO,' International Symposium on Research Reactor and Neutron Science, pp. 294-296
  4. Kang, Y.H., Cho, M.S., Kim, B.G. and Choi, Y., 2005, 'Statues of the Study on the Irradiated Materials by a Special Capsule in HANARO,' 18th Int. Conf. on Structural Mechanics in Reactor Technology, pp. 1037-1040
  5. Cho, M.S. et al., 2006, 'The Irradiation Test Plan of the 04S-23K Creep Capsule,' KAERI/TR-3175/2006, KAERI
  6. Vandermeulen, W., Hendrix, W., Massaut, V. and Velde, J. Van. de, 1991, 'The Effect of Neutron Irradiation on the Fatigue Behaviour of AISI 316L-Results of First In-pile Tests,' Journal of Nuclear Materials, Vol. 183, pp. 57-61 https://doi.org/10.1016/0022-3115(91)90470-R
  7. Nieuwenhove, R.V. and Moons, F. 1994, 'In-pile AISI 316L Low Cycle Fatigue,' FT/Mol/95-01, Belgium
  8. Park, S.J., Cho, M.S., Choi, M.H. and Kim, B.G., 2005, 'Fatigue Capsule Control System (FTCTS-2005) MMI Program,' Registration No.: 2005-01-182-005647, Program Deliberation & Mediation Committee
  9. Doebelin, E.O., 1990, Measurement Systems; application and design, McGraw-Hill, New York, USA
  10. Hong, S.G., Yoon, S.S. and Lee, S.B., 2004, 'The Influence of Temperature on Low Cycle Fatigue Behavior of Prior Cold Worked 316L Stainless Steel(I),' Journal of the KSME, Vol. 28, No. 4, pp. 333-342 https://doi.org/10.3795/KSME-A.2004.28.4.333
  11. Kim, D.W., Ryu, W.S., Hong, J.H. and Choi, S.K., 1998, 'Effect of Nitrogen on High Temperature Low Cycle Fatigue Behaviors in Type 316L Stainless Steel,' Journal of Nuclear Materials, Vol. 254, pp. 226-233 https://doi.org/10.1016/S0022-3115(97)00360-7
  12. Choi, M.H. et al., 2006, 'Performance Test of a Capsule Load Device and Fatigue Test using the Device,' KAERI/TR-3191/2006, KAERI
  13. Bannantine, J.A., Comer, J.J. and Handrock, J.L. 1990, Fundamentals of Metal Fatigue Analysis, Prentice Hall, New Jersey, USA