참고문헌
- Bidez MW, McLoughlin SW, Chen Y et al. Finite element analysis of two-abutment Harder bar designs. Implant Dent 1993;2:107-114 https://doi.org/10.1097/00008505-199305000-00008
- Rangert B, Jemt T, J?rneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241-247
- Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-44
- Hoshaw S, Brunski J, Cochran G. Mechanical loading of Branemark fixtures affects interfacial bone modelling and remodelling. Int J Oral Maxillofac Implants 1994;9:345-360
- Zarb GA, Symington JM. Osseointegrated dental implants: preliminary report on a replication study. J Prosthet Dent 1983;50:271-276 https://doi.org/10.1016/0022-3913(83)90029-X
- Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-585 https://doi.org/10.1016/0022-3913(89)90084-X
- Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5years. Int J Oral Maxillofac Implants 1994;9:169-178
- Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-160
- Pietrabissa R, Gionso L, Quaglini V, Martino E, Simion M. An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses. Clin Oral Implants Res 2000;11:448-457 https://doi.org/10.1034/j.1600-0501.2000.011005448.x
- Jemt T, Linden B. Fixed implant-supported prostheses with welded titanium frameworks. Int J Periodont Rest Dent 1992;12:177-184
- Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-625
- Jemt T, Lekholm U. Measurements of bone and framework deformations induced by misfit of implants superstructures. A pilot study in rabbits. Clin Oral Implants Res 1998;9:272-280 https://doi.org/10.1034/j.1600-0501.1998.090408.x
- Carr AB, Gerard DA, Larsen PE. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996;76:500-509 https://doi.org/10.1016/S0022-3913(96)90008-6
- Carr AB, Stewart RB. Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing. J Prosthodont 1993;2: 2-8 https://doi.org/10.1111/j.1532-849X.1993.tb00373.x
- Linke BA, Nicholls JI, Faucher RR. Distortion analysis of stone casts made from impression materials. J Prosthet Dent 1985;54:794-802 https://doi.org/10.1016/0022-3913(85)90473-1
- Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996;11:216-222
- Humphries RM, Yaman P, Bloem T. The accuracy of implant master casts constructed from transfer impressions Int J Oral Maxillofac Implants 1990;5:331-336
- Gettleman L, Ryge G. Accuracy of stone, metal and plastic die material. J Calif Dent Assoc 1970;46:28- 31
- White GE. Osseointegrated Dental Technology. Chicago: Quintessence 1995:123-124
- Adell R, Lekholm U, Rockler B, Branemark P-I. A 15-year study of osseointegrated implant in the treatment of the edentulous jaws Int J Oral Surg 1981;10:387-416 https://doi.org/10.1016/S0300-9785(81)80077-4
- Tan KB, Rubenstein JE, Nicholls JI, Yuodelis RA. Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. Int J Prosthodont 1993;6:346-363
- Adell R, Eriksson B, Lekholm U, Branemark P-I, Jemt T. A long-term follow-up of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-359