Abstract
Parameters including the seismic sources and the elastic wave propagation characteristics were analysed using the observed ground motions from 12 Fukuoka region earthquakes. The Levenberg-Marquardt algorithm was applied to invert all the variables non-linearly and simultaneously with S wave energy in fiequency domain. Average stress drop of 12 events and local attenuation parameter $\kappa$ under seismic stations were estimated to about 79.2-bar and 0.043 respectively. Regional attenuation parameter, Qo and ${\eta}$, were also estimated to be about 248.1 and 0.558 respectively. Low value of Qo seems to caused by inhomogeneous tectonic characteristics between Japan island and southern Korean peninsula. $\kappa$ values are much higher than that characterizing EUS (Eastern United States) region, and nearly similar to that of WUS (Western Waited States) region. If the informations on site specific amplification of all the seismic stations are known, $\kappa$ values can be estimated more precisely. All the values including the seismic sources and the site and crustal scale propagation characteristics can be used as seismic design parameters.
본 연구는20005년 3월부터 약2개월에 걸쳐 후쿠오카 지역에서 짧은 기간에 발생한 12개의 지진으로부터 관측된 154개의 지반진동 자료를 이용하여 지진원 및 지진파 감쇠와 관련된 값들을 분석하였다. 본 연구에서는 구하고자 하는 모든 값을 동시에 비선형적으로 분석하기 위해 LM(Levenberg-Marquardt) 역산방법을 적용하였고 전단파 에너지를 이용하였다. 분석결과 12개 지진의 응력강하값의 평균은 약 79.2-bar이고 부지 하부 지진파 감쇠값 $\kappa$의 평균값은 0.043으로 분석되었다. 또한 광역적인 지진파 감쇠를 나타내는 Qo 와 ${\eta}$값은 각각 248.1 및 0.558로 분석되었다. Qo 과 ${\eta}$값은 지진파의 경로중 일부가 동해를 거치기 한반도 남동부의 지진파 전파의 특성뿐만 아니라 일본과 한반도 사이의 지체구조의 차이로 인한 불균질 특성도 포함하고 있는 것으로 판단된다. 특히 관측소부지 하부의 지진파 감쇠값 K의 평균값은 미국 동부지역 대표값 보다 훨씬 크고 미국 서부지역 대표값보다 거의 유사한 값을 보여 주었으며 각각 관측소 부지 고유의 증폭에 대한 정확한 정보가 있으면 보다 의미있는 결과를 얻을 수 있다고 판단된다.