Operational Characteristics of Wind Turbine Generator Systems in Hangwon Wind Farm

행원 풍력발전단지에서 풍력발전시스템의 운전특성

  • Ko, Kyung-Nam (Clean Energy Education Center, Cheju National University) ;
  • Kang, Mun-Jong (Dept. of Mechanical Engineering, Graduate School, Cheju National University) ;
  • Huh, Jong-Chul (Faculty of Mechanical Energy System Engineering, Cheju National University)
  • 고경남 (제주대학교 청정에너지사업단) ;
  • 강문종 (제주대학교 기계공학과 대학원) ;
  • 허종철 (제주대학교 기계에너지시스템공학부)
  • Published : 2007.03.30

Abstract

This paper reveals both the operational situation and the cause of the error occurred in wind turbine generator system of Hangwon wind farm in Jeju island. The four wind turbines were selected for this work, and the monitored period was for six months. Wind resource in the wind farm was analyzed, and the estimated energy production was compared with the actual energy production. As a result, with a decrease of system error, the estimated energy production was in good agreement with the actual energy production. The errors occurring in components such as gearbox and hydraulic motor affected the Availability of the wind turbine. Also, poor external conditions such as a strong wind, lightning and gust caused a standstill of wind turbines.

Keywords

References

  1. BTM Consult ApS, http://www.btm.dk/,2006
  2. 세계일보,대체에너지 개발 용두사미?,http://www.sedye.com/service5/view. 2006. 5. 9
  3. 변수환,고경남,허종철,행원 풍력발전단지의 WAsP 적용 및 평가,한국태양에너지학회,제 24권 3호,2004
  4. J.F. Manwell, J,G, McGowan A.L. Rogers, Wind Energy Explained, John Wiley & Sons Ltd, 2004
  5. 고경남,허종철,풍력공학입문,문운당,2006
  6. IEC, Wind Turbine Generator Systems. Part 1: Safety Requirements, 2nd Ed., IEC 61400-1, 1999
  7. IEC, Wind Turbine Generator Systems. Part 12 Wind Turbine Power Performance Testing, 1st Ed., IEC 61400-12, 1998
  8. Vestas Wind Systems A/S, V42-600kW, V47-660kW Manual, 2004
  9. 기상청, http://www.kma.go.kr