This experiment was analysed the discharge characteristics of FFL(flat fluorescent lamp). FFL is operated by sine and pulse wave source. We use FFL which has the electrodes covered with dielectric, observed the discharge characteristics of FFL by V-Q Lissajous' figure. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. When the duty ratio increases, the number of metastable xenon atoms seem to increase. Consequently, the 172nm radiation becomes strong as the duty ratio increases.

본 논문에서는 FFL에 대한 기초 방전특성의 일부분으로 인가전압을 정현파와 구형파로 변화시켜 V-Q Lissjous 도형을 이용하여 FFL의 방전형태를 분석하고, 인가전압의 듀티비(duty ratio)의 면화에 의한 radiation transition에 대하여 고찰하였다. FFL을 정현파와 펄스파을 이용하였고, 절연층으로 둘러 쌓여 있는 전극을 갖는 FFL의 방전 특성을 V-Q 리사쥬 도형을 이용하여 방전 특성을 고찰하였다. FFL은 펄스파로 구동하였을 때 방전 전류는 전압의 상승 순간에 방전 전류가 흐른다. 듀티비가 증가하면 준안정 준위의 Xe 원자들은 증가하며 172nm의 자외선 방사량이 증가하고 있음을 확인할 수 있었다.

Keywords

References

  1. K. Sakita, K Takayama, K. Awamoto and Y. Hashimoto, 'Analysis of cell operation at address period using wall voltage transfer function in three-electrode surface-discharge AC-PDPs', Proc. of IDW01, pp.841-844, 2001. 12
  2. Larry F. Weber, 'Measurement of Wall Charge and Capacitance Variation for a Single Cell in AC Plasma Display Panel', IEEE Trans.ElecronDevices, Vol. ED-24, p.864, 1977
  3. Masafumi Jinno, Hisayoshi Kurokawa andMasaharu Aono, 'Fundamental Research on Mercuryless Fluorescent Lamp II', Jpn. J. Appl.Phys,Vol. 38, pp.4613-4617, 1999. July https://doi.org/10.1143/JJAP.38.4613
  4. Hashimoto, 'Analysis of cell operation at address period using wall voltage transfer function in three-electrode surface-discharge AC-PDPs', Proc. of IDW01, pp.841-844, 2001. 12
  5. S. S. Kwon, M. S. Lim, K. J. Lim, B. H. Ryu, S.G. Park. 'AC Flat Fluorescent Lamp for LCD Backlighting', Proc.Of ICEE 1998, 99.984-987, 1998
  6. S. S. Kwon, M. S. Lim, K. J. Lim, B.H. Ryu, S. G. Park. 'Characteristics of a Simple Structured Flat Fluorescent Lamp with High Luminance for LCD Backlighting', Proc. Of ICEE 1999, pp.676-680, 1999