Abstract
In Activated Sludge Model, COD fraction of primary settled municipal wastewater was a very important parameter. In this study, the COD fraction was determined using the oxygen utilization rate experiments. Readily biodegradable COD ($S_S$) fraction was observed about 29.7% of influent TCOD. $S_I$, $X_I$, and $X_S$ were analyzed to be 7.6%, 7.3%, and 55.4% of TCOD, respectively. The model used in this study was developed based on ASM3 and modified Bio-P module in order to simulate the existing BNR process. Parameter estimation results showed that $Y_{STO,O2}$, $Y_{STO,NO}$, $Y_{H,O2}$, $Y_{H,NO}$, $Y_{PO4}$, ${\mu}_H$, $b_H$, ${\mu}_A$, $q_{PHA}$, $q_{PP}$ and ${\mu}_{PAO}$ were 0.7, 0.64, 0.61, 0.48, 0.31, 3.9, 0.1, 1.35, 4.98, 1.8 and 0.59, respectively. Using the presented model and the estimated parameters, the simulation of the existing BNR process was successfully conducted.