대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas

  • 이장훈 (광운대학교 환경공학과) ;
  • 강선홍 (광운대학교 환경공학과)
  • 투고 : 2007.09.10
  • 심사 : 2007.10.04
  • 발행 : 2007.10.15

초록

This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

키워드

참고문헌

  1. 국립환경연구원 (1994) 분뇨처리장에서 발생한 악취의 생물학적 처리기술개발
  2. 박상진 (1993) 폭기조 및 토양탈취상을 이용한 하수처리장의 악취제거. 한국건설기술연구원
  3. 박정진 (2000) 바이오필터를 이용한 황화수소의 처리. 포항공대 석사학위논문
  4. 송승구 (1996) 미생물 부착을 촉진시키는 입자의 제조방법. 제4513호
  5. 통상산업부 (1995) 생물학적 처리 방식에 의한 배기가스 정화조 개발에 관한 연구
  6. Both, R. (2001) Directive on odour in ambient air: an established systcm of odour measurement and odour Regulation in Cennany, Water Sci. Technol., 44, pp. 119-126
  7. Cbo, K.S., Zbang, L., Hirai, ,M. and Shoda, M. (1991) Removal characteristics ofhvdrogen sulfide and mcthanerhiol by Tbiobncillns sp. isolated from peat in biological deordorizatioll, Jour. Ferment. Bioeng., 71, pp. 44-49 https://doi.org/10.1016/0922-338X(91)90302-W
  8. Leson, C., Willer, A.M. (1991) Biofiltration: An innovative air pollution control technology for VOC: emissions, Jour. Air & Waste Manage Assoc., 41, pp. 1045-1054 https://doi.org/10.1080/10473289.1991.10466898
  9. Sublette, K.L., and Sylvester, N.D. (1987) Oxidation of hydrogen sulfide by Tbiobacillus denitrifications: dcsulfurizarion of natural gas, Biotechnol. Bioeng., 29, 249-257 https://doi.org/10.1002/bit.260290216