• 제목/요약/키워드: ISO Standard Fire Curve

검색결과 29건 처리시간 0.034초

지하주차장의 내화성능 평가를 위한 차량연소실험 (The combustion test of assuming in parking space for fire resistance)

  • 강승구;김동준;이재영;原田和典;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

표준화재곡선을 이용한 잔존부착강도 평가 간략방법 제안 (Simplified Evaluation Method for Residual Bond Strength of Reinforced Concrete Using Standard Fire Curve)

  • 문도영
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.41-47
    • /
    • 2010
  • 화해를 입은 구조물의 안전성 확보에는 초기대응이 매우 중요기 때문에 신속한 의사결정이 필요하다. 본 논문에서는 화해를 입은 구조물의 이형철근과 콘크리트 간 잔존부착강도를 평가할 수 있는 간략화된 방법을 제시하였다. 제안된 방법은 화재강도 즉, 화재 중 최고노출 온도 뿐 아니라 화재지속시간도 고려할 수 있도록 하였다. 제안된 방법의 검증 및 비교를 위하여 화해를 입은 대구지하철 역사의 현장조사 결과를 인용하였으며, 해석결과 그 효용성을 확인하였다.

화재에 의한 지하공동구의 온도 및 응력해석 (Temperature and Stress Analysis of Box Culvert in Fire)

  • 김현준;임초롱;유현경;정철헌
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.31-44
    • /
    • 2011
  • This paper has presented a finite element analysis of structural behaviour of box culvert during and after fires. The fire tests were carried out in a furnace on RC slabs using the ISO 834 standard fire curve. The load capacity after cooling of the RC slab that was not loaded during the fire tests was evaluated by means of additional 3 points bending tests. In the past, stress-strain models of concrete under fire loading have been proposed by several researchers. Comparisons are made with the load-displacement relations of RC slabs after fire loading using the existing stress-strain models with temperature, such as Schneider, EUROCODE 2, Lie, Shi and Nan model. By comparing the load-displacement relations, Lie model was found to result in a maximum load about 2.0% higher than that of test. Based on the fire test results of RC slabs, this paper presents an extensive analytical study on the fire response of box culvert during and after fires.

강재 영구거푸집을 사용한 yLRC 합성기둥의 내화성능 연구 (A Study on the Fire Resistance of yLRC Composite Columns with Steel Sheet Forms and Angles)

  • 김보람;강성덕;김형근;김명한;김상대
    • 한국강구조학회 논문집
    • /
    • 제20권3호
    • /
    • pp.365-375
    • /
    • 2008
  • yLRC 합성기둥은 기존 합성기둥의 장점과 거푸집 공사의 절감을 가져올 수 있으며, CFT와 비교하였을 때 강재량 감소의 효과와 함께 콘크리트의 충전상태를 육안으로 쉽게 확인할 수 있는 등의 장점을 가지고 있다. 실험결과와 연구를 통하여 yLRC 합성기둥의 구조체로서의 내력은 검증이 되었으나 내화성능에 관한 연구는 수행되지 않았다. 이에 본 논문에서는 yLRC 합성기둥의 내화성능 평가를 위해 콘크리트 면적비, 보강판, 피복유무 등을 변수로 두어 실험과 해석을 수행하였으며, 실험과 해석결과를 비교 고찰하여 내화 성능 평가를 하였다.

터널의 내화성능 평가용 화재온도곡선과 화재모델별 내화시간에 대한 고찰 (A study on the deterministic temperature-time curves and required resistance times by fire model for assessment of fire resistance of tunnel structures)

  • 김효규;박경환;윤명오;이창우
    • 한국터널지하공간학회 논문집
    • /
    • 제7권2호
    • /
    • pp.165-176
    • /
    • 2005
  • 최근 전세계의 대형화재 사고이후, 터널안전에 관한 많은 연구들이 진행되고 있다. 특히 실물 및 축소모형 실험에 대한 다양한 연구가 진행되면서, 터널구조물에 대한 내화성능에도 많은 관심이 모아지고 있다. 이미 외국에서는 터널구조물의 내화성능에 대한 설계기준이나 권고안이 발표되고 있으나, 아직 국내에는 설계기준으로 마련되지 못하고 있다. 본 연구의 목적은 각 나라별 화재온도 (온도-시간) 곡선, 특히 ISO 834 표준온도곡선, HC곡선, RWS곡선, ZTV곡선, EBA곡선을 분석하여 국내의 도로, 지하철 및 철도터널의 내화성능 평가 기준에 적합한 화재특성을 도출하는데 있다.

  • PDF

화재시 온도증가로 인한 RC 슬래브의 강도 특성 (Strength Properties of RC Slabs under Elevated Temperatures from Fire)

  • 임초롱;정철헌;김유석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.

iTECH 합성보의 내화성능에 대한 실험연구 (Experimental Study on the Fire Resistance of the iTECH Composite Beam)

  • 이승재;강성덕;최승관;김명한;김상대
    • 한국강구조학회 논문집
    • /
    • 제18권5호
    • /
    • pp.643-654
    • /
    • 2006
  • 본 연구에서는 iTECH 합성보 실험체에 대한 온도와 변형에 대한 내화성능을 ISO834 표준화재와 BS476-20 및 KSF2257 기준에 근거하여 평가하였다. 국내외적으로 복합구조의 내화성능을 규명하기 위한 연구는 지극히 미흡한 실정이며, 따라서 본 연구에서는 iTECH 합성보의 내화성능을 평가하기 위해 1.5m의 슬래브를 포함한 4..7m의 스팬길이에 대하여 실험을 수행하였다. 변수는 실험체의 단면크기, 피복재 보강방법과 보강두께, 그리고 하중비로 하여 내화실험을 수행하였다.

화재피해를 입은 RC 슬래브의 재하실험에 관한 연구 (A Study on the loading test for of slab by Fire damaged)

  • 이규민;강승구;김동준;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2013
  • In case of Korea, it goes frequently that underground parks has been burned. Based on standard temperature time curve(ISO-834), gerber, walls, slab of structures are constructed. However, Standard temperature time Curve is not considered that buildings are affected by vehicle fire. that is why it has the hazard that makes building reinforcement feeble. Based on the result that got from vehicle experiment before, we made four RC slab in this experiment and set the fire severity. according to the loading experiment after heating, we measured the effects that makes reinforcement and shape changes. Furthermore, we examined the safty of the structure by comparing before and after heating.

  • PDF

비재하 가열에 의한 무내화피복 CFT 기둥의 잔존내력 예측에 관한 연구 (A Study on the Prediction of Residual Strength of Concrete Filled Steel Tube Column without Fire Protective Coating by Unstressed Heating)

  • 김규용;이형준;이태규;김영선;강선종
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.31-39
    • /
    • 2009
  • 최근 고층건물의 화재안전성에 대한 문제점이 사회적으로 부각되어지고 있으며, 이러한 고층 건물에 다수 사용되고 있는 CFT기둥 부재에 대한 내화성능을 정량적으로 평가하는 방법이나 기준들이 마련되지 않은 상황이다. 이에 본 연구에서는 고강도 콘크리트를 충전한 CFT 단주를 제작하여 내화실험을 실시하고, 화재시 내화성능평가 및 비정상온도분포해석을 이용한 해석을 수행하여 온도분포해석의 모델링을 제안할 수 있었다. 이것을 기초로 CFT Stub Column의 고온특성 평가결과를 활용하여 화재시 내화시간에 따른 CFT기둥의 잔존내력 예측식을 유도할 수 있었다.

화재피해를 입은 고강도 콘크리트 구조부재의 성능평가 (Performance Assessment of High Strength Concrete Members subjected to Fire)

  • 최은규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.487-488
    • /
    • 2010
  • 본 연구에서는 화재시 콘크리트 강도, 피복두께, 하중상태 및 화재시간이 부재 내부의 열적 분포 및 구조적 거동에 미치는 영향을 파악하기 위하여, 일반강도 및 고강도 콘크리트 보 및 기둥 시험체를 제작하여 각 변수에 따라 ISO 834 표준가열곡선으로 가열실험 및 가력실험을 실시하였으며, 고온에서 콘크리트의 재료 및 구조모델을 제안하고 이를 이용하여 해석을 실시하였다.

  • PDF