생체흡수성 고정장치를 이용한 상악골 이동술 후 장기간 결과

STABILITY OF MAXILLARY POSITION AFTER LEFORT I OSTEOTOMY USING BIODEGRADABLE PLATES AND SCREWS

  • 김봉철 (연세대학교 치과대학 구강악안면외과학교실) ;
  • 정영수 (연세대학교 치과대학 구강악안면외과학교실)
  • Kim, Bong-Chul (Dept. of Oral and Maxillofacial Surgery, Oral Science Research Center, College of Dentistry, Yonsei University) ;
  • Jung, Young-Soo (Dept. of Oral and Maxillofacial Surgery, Oral Science Research Center, College of Dentistry, Yonsei University)
  • 발행 : 2007.10.31

초록

Introduction: In orthognathic surgery, internal fixation has been usually done with titanium plates and screws. Recently, Biodegradable plates and screws have been frequently used but the reports of long term results of postoperative stability are rare, especially after maxillary reposition in orthognathic surgery. Objective: In order to clarify the clinical utility of self-reinforced bioresorbable poly-70L/30DL-Lactide miniplates & screws in maxillary fixation after LeFort I osteotomy, this study examined the postsurgical changes in maxilla and complications of biodegradable plates and screws. Study design: Nineteen patients who had undergone maxillary internal fixation using biodegradable plates and screws were evaluated radiographically and clinically. A comparison study of the changes in maxilla position after surgery in all 19 patients was performed with 1-week, 1-month, 3-months, 6-months and/or 1-year postoperative lateral cephalograms by tracing. Complication of the biodegradable plates and screws was evaluated by follow-up roentgenograms and clinical observation. And one-way ANOVA test was used for statistical analysis. Results: The position of the maxillary bone was stable after surgery and was not changed significantly from 1 week to 1 year after operation. And we could not find any complication of biodegradable plates and screws. Conclusions: Internal fixation of the maxilla after LeFort I osteotomy using self-reinforced biodegradable plates and screws is a reliable method for maintaining postoperative position of the maxilla after LeFort I osteotomy.

키워드

참고문헌

  1. Ylikontiola L, Sundqvuist K, Sandor GKB, et al: Self-reinforced Bioresorbable poly-L / DL-Lactide (SR-P(L / DL)LA) 70 / 30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures: A pilot study. Oral Sur Oral Med Oral Pathol 2004;97:312-317 https://doi.org/10.1016/j.tripleo.2003.10.030
  2. Peltoniemi H, Ashammakhi N, Kontio R, et al: The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Sur Oral Med Oral Pathol 2002;94:5-14 https://doi.org/10.1067/moe.2002.122160
  3. Haers PE, Sailer HF: Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures. J Craniomaxillofac Surg 1998;26:363-372 https://doi.org/10.1016/S1010-5182(98)80069-3
  4. Jorgenson DS, Mayer MH, Ellenbogen RG, et al: Detection of titanium in human tissues after craniofacial surgery. Plast Reconstr Surg 1997;99:976-979 https://doi.org/10.1097/00006534-199704000-00006
  5. McManners J, Moos KF, El-Attar A: The use of biodegradable fixation in sagittal split and vertical subsigmoid osteotomy of the mandible: a preliminary report. Br J Oral Maxillofac Surg 1997;35: 401-405 https://doi.org/10.1016/S0266-4356(97)90716-6
  6. Kallela I, Tulamo RM, Hietanen J, et al: Fixation of mandibular body osteotomies using biodegradable amorphous self-reinforced (70L:30DL) polylactide or metal lag screws: an experimental study in sheep. J Craniomaxillofac Surg 1999;27:124-133 https://doi.org/10.1016/S1010-5182(99)80026-2
  7. Kallela I, Laine P, Suuronen R, et al: Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws. Int J Oral Maxillofac Surg 1998;27:3-8 https://doi.org/10.1016/S0901-5027(98)80086-6
  8. Park HS, Cha IH, Park HR: A study on accuracy of maxillary repositioning by external measuring techique. J Kor Maxillofac Plast Reconstr Surg 1991;13:44-51
  9. Edwards RC, Kiely KD, Eppley BL: Fixation of bimaxillary osteotomies with resorbable plates and screws: experience in 20 consecutive cases. J Oral Maxillofac Surg 2001;59:271-276 https://doi.org/10.1053/joms.2001.20988
  10. Suuronen R, Manninen MJ, Pohjonen T, et al: Mandibular osteotomy fixed with biodegradable plates and screws: an animal study. Br J Oral Maxillofac Surg 1997;35:341-348 https://doi.org/10.1016/S0266-4356(97)90407-1
  11. Mazzonetto R, Paza AO, Spagnoli DB: A retrospective evaluation of rigid fixation in orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polyactide. Int J Oral Maxillofac Surg 2004;33:664-669 https://doi.org/10.1016/j.ijom.2004.02.001
  12. Yerit KC, Hainich S, Enislidis G, et al: Biodegradable fixation of mandibular fractures in children: Stability and early results. Oral Sur Oral Med Oral Pathol Oral Radiol Endod 2005;100:17-24 https://doi.org/10.1016/j.tripleo.2004.11.013
  13. Delaire J, Schendel SA, Tulasne JF: An architectural and structural craniofacial analysis: a new lateral cephalometric analysis. Oral Surg 1981;52:226 https://doi.org/10.1016/0030-4220(81)90252-8
  14. Kim IH, Yi CK: architectural and structural craniofacial analysis of Korean adults. J Kor Oral Maxillofac Surg 1991;17(4):33-44
  15. Shand JM, Heggie AAC: Use of a resorbable fixation system in orthognathic surgery. Br J Oral Maxillofac Surg 2000;38(4):335-337 https://doi.org/10.1054/bjom.1999.0287
  16. Haers PE, Suuronen R, Lindqvist C, et al: Biodegradable polylactide plates and screws in orthognathic surgery: technical note. J Craniomaxillofac Surg 1998;26(2):87-91 https://doi.org/10.1016/S1010-5182(98)80045-0
  17. Turvey TA, Bell RB, Tejera TJ, et al: The use of self-reinforced biodegradable bone plates and screws in orthognathic surgery. J Oral Maxillofac Surg 2002;60(1):59-65 https://doi.org/10.1053/joms.2002.28274
  18. Steiner M, Von Fraunhofer JA, Mascaro J: The possible role of corrosion in inhibiting the healing of a mandibular fracture : report of a case. J Oral Surg 1981;39:140
  19. Wright JK, Axon HJ: Electrolysis and stainless steel in bone. J Bone Joint Surg 1956;38B:745
  20. Bago-Granell J et al: Malignant fibrous histiocytoma of bone at the site of a total hip arthroplasty. J Bone Joint Surg 1984;66B:38
  21. Messer EJ, Hayes DC, Bitbe PJ: Use of intraosseous metal appliances in fixation of mandibular fractures. J Oral Surg 1967;25:493
  22. Bouwman JP, Tuinzing DB, Kostense PJ: A Comparative in vitro study on fixation of sagittal split osteotoies with Wurzburg screws, Champy miniplates, and Biofix (biodegradable) rods. Int J Oral Maxillofac Surg 1994;23:46
  23. Cheung LK, Chow LK, Chiu WK: A randomized trial of resorbable versus titanium fixation for orthognathic surgery. Oral Sur Oral Med Oral Pathol Oral Radio Endod 2004;98:386-397 https://doi.org/10.1016/j.tripleo.2004.02.069
  24. Shand JM, Heggie AA: Use of a resorbable fixation system in orthognathic surgery. Br J Oral Maxillofac Surg 2000;38:335-337 https://doi.org/10.1054/bjom.1999.0287
  25. Turvey TA, Bell RB, Tejera TJ, et al: The use of selfreinforced biodegradable bone plates and screws in orthognathic surgery. J Oral Maxillofac Surg 2002;60:59-65 https://doi.org/10.1053/joms.2002.28274
  26. Haers PE, Sailer HF: Biodegradable self-reinforced poly-L/DLlactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures. J Craniomaxillofac Surg 1998;26:363-372 https://doi.org/10.1016/S1010-5182(98)80069-3
  27. Kumar AV, Staffenberg DA, Petronio JA, et al: Bioabsorbable plates and screws in pediatric craniofacial surgery: a review of 22 cases. J Craniofac Surg 1997;8:97-99 https://doi.org/10.1097/00001665-199703000-00006
  28. Kim YK, Yeo Hh, Lim SC: Tissue response to titanium plates: a transmitted electron microscopic study. J Oral Maxillofac Surg 1997;55:322-326 https://doi.org/10.1016/S0278-2391(97)90115-4
  29. Iizuka T, Lindqvist C: Rigid internal fixation of mandibular fractures. An analysis of 270 fractures using the AO/ASIF method. Int J Oral Maxillofac Surg 1992;21:65-69 https://doi.org/10.1016/S0901-5027(05)80533-8
  30. Kulkarni RK, Pani KC, Neuman C, et al: Polylactic acid for surgical implants. Arch Surg 1966;93:839-43 https://doi.org/10.1001/archsurg.1966.01330050143023