In this paper, the 1/5 scale models of the reinforced concrete colunms were designed and fabricated. The influence of the number of blasting holes on the exposed length of steel bars and vertical load was investigated. The relation between the length of steel bar and the number of blasting holes was examined by performing the blast tests considering the vertical load on the scaled reinforced concrete columns. Weight of scaled column models by blasting and that of exposed was compared with the number of blasting holes. Finally, based on the exposed length of steel bars and vertical load, the number of blasting holes were calculated. Results shows that the number of blasting holes calculated in this study are suitable for scaled structure models test by blasting demolition.
본 연구에서는 1/5 축소모형 철근콘크리트 기둥을 이용하여 철근의 노출길이 및 수직하중과 발파공수와의 관계에 대해 연구하였다. 축소모형 철근콘크리트 기둥에 수직하중을 재하하여 철근의 노출 길이와 발파공수와의 관계를 비교하였다. 또한 발파된 축소모형 기둥의 무게와 철근이 노출된 축소모형 기둥의 무게를 발파공수와 비교하였다. 축소모형 철근콘크리트 기둥에 대한 시험결과로부터 철근의 노출길이 및 수직하중을 바탕으로 축소모형 철근콘크리트 기둥의 발파공수를 산정할 수 있으며, 이를 축소모형 구조물에 적용할 수 있음을 확인하였다.