Abstract
A rapid analytical method was developed to quantify very long-chain fatty acids (VLCFAs, C22:0, C24:0, C26:0) in human plasma with good sensitivity and specificity using tert-butyldimethylsilyl (TBDMS) derivatization and stable isotope GC-MS selective ion monitoring (GC-MS/SIM). Two-hundred and fifty ${\mu}L$ of plasma was fortified with deuterated stable isotope internal standards (d3-C22:0, d3-C24:0, d3-C26:0) and standard mixtures of chloroform and methanol, and then extracted with hexane and acetonitrile. To upper layer of liquid-liquid-extraction, N-(t-Butyldimethylsilyl)-N-methyltrifluoroacetamide was added and then heated to $60^{\circ}C$ for 30 min to produce the TBDMS derivatives. Derivatives of VLCFAs were analyzed by GC-MS/SIM. Calibration curves showed a linear relationship for the target compounds in the concentration range of $10^{-4}{\sim}2{\times}10^3\;{\mu}g/mL$ with the correlation coefficient ranging from 0.996 to 0.999. The limit of quantification for the plasma was $10^{-4}{\sim}2{\times}10^{-4}\;{\mu}g/mL$ (S/N=3). When applied to the plasma specimens of patients with peroxisomal disorder, X-linked adrenoleucodystropy (ALD, Mckusick 202370), the method clearly differentiated normal subjects from ALD patients. The C24:0/C22:0 and C26:0/C22:0 ratios were significantly elevated in the plasma of patients with X-linked ALD compared to normal subjects. The new developed method might be useful for a rapid and sensitive diagnosis of X-linked ALD and other peroxisomal disorders.