Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -

공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-

  • Choi, Yong-Don (Department of Mechanical Engineering, Korea University) ;
  • Kang, Yong-Tae (School of Mechanical and Industrial System Engineering, Kyung Hee University) ;
  • Kim, Nae-Hyun (Department of Mechanical Engineering, University of Incheon) ;
  • Kim, Man-Hoe (Department of Mechanical Engineering, KAIST) ;
  • Park, Kyoung-Kuhn (School of Mechanical mid Automotive Engineering, Kookmin University) ;
  • Park, Byung-Yoon (Department of Architecture, Suwon Science College) ;
  • Park, Jin-Chul (School of Architecture, Chung-Ang University) ;
  • Hong, Hi-Ki (School of Mechanical and Industrial System Engineering, Kyung Hee University)
  • 최영돈 (고려대학교 기계공학과) ;
  • 강용태 (경희대학교 기계산업시스템공학부) ;
  • 김내현 (인천대학교 기계공학과) ;
  • 김만회 (한국과학기술원 기계공학과) ;
  • 박경근 (국민대학교 기계자동차공학부) ;
  • 박병윤 (수원과학대학 건축과) ;
  • 박진철 (중앙대학교 건축학부) ;
  • 홍희기 (경희대학교 기계산업시스템공학부)
  • Published : 2007.01.10

Abstract

A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Keywords

References

  1. Ryu, M. S. and Kim, C. N., 2004, A numerical analysis of the abatement of VOC with different photocatalytic honeycomb filters, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp.1-7
  2. An, B. C. and Oh, M. D., 2004, A study on the filter media and performance of intake air filter for vehicular engine, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp.8-15
  3. Kwon, K. M., Jeong, S. Y., Kim, B. J. and Jeong, E. S., 2004, Heat and mass transfer characteristics of a falling film ammonia absorber with respect to the vapor flow direction, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp.16-25
  4. Park, C. W., Cho, H. C. and Kang, Y. T., 2004, A study on the performance characteristics of an absorption chiller for variable cooling water flow rate at partial load conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp, 26-33
  5. Yoo, S. Y., Hong C. P. and Shim, W. S., 2004, A study on the performance of thermoelectric module and thermoelectric cooling system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 62-69
  6. Kim, C.-D., Park, I.-H. and Lee, J., 2004, Prediction and experiment of pressure drop of R22, R407C and R410A on design conditions of condenser, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp.42-53
  7. Park, J. C., 2004, A study on the improvement of energy performance in school buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp. 54-61
  8. Yoo, S.-Y., Hong, C.-P. and Shim, W.-S., 2004, A study on the performance of thermoelectric module and thermoelectric cooling system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp.62-69
  9. Park, S. Y. and Boo, J. H., 2004, An experimental study on the heat transfer characteristics of high-temperature cylindrical heat pipes, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp.70-76
  10. Kim, Y. C. and Han, Y. H., 2004, An experimental study on ultrasonic spray cooling of heat pipe condenser, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp.77-83
  11. Kim, M.-G., Kim, W.-J. and Kim, Y. J., 2004, Numerical study for the effect of expansion device on the performance of the $CO_2$ cycle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp. 84-90
  12. Park, Y. C., Moon, J. M. and Hong, J. T., 2004, An overview on standards for seasonal performance evaluation of multi-type air conditioners, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 1, pp.91-100
  13. Yoo, H. S., Hyun, S. K., Park, Y. W., Kim, Y. S. and Hong, H., 2004, Analysis of heating energy in a Korean-style apartment building 1: the effect of location, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.1, pp.101-110
  14. Kim, T. Y. and Lee, Y. G., 2004, Optimal design for indoor thermal evironment based on CFD simulation and genetic algorithms, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 111-120
  15. Hwang, Y. S., Lee, D. Y. and Kim, W. S., 2004, Conceptual development of a subminiature cool pad applying sorption cooling effect, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 121-127
  16. Kim, J. H., Kim, S. S., Choi, B. S. and Hong, H., 2004, Verification experiment and analysis for 6 kW solar water heating system (Part 1: verification experiment), Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 128-134
  17. Lee, S. R., Ryou, H. S. and Kim, C. I., 2004, An experimental study of smoke movement in tunnel fires with a vertical shaft, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp.135-141
  18. Kim, K. M., Park, K. W. and Kwon, I. W., 2004, Effect on ice slurry flowing in the elbow of various angle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 142-149
  19. Choi, H. S., Kang, B. H., Park, K. K. and Kim, S., 2004, An experimental study on miscibility and vapor pressure of R-744/oil mixtures, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 150-157
  20. Cho, H., Kim, Y. and Seo, K. J., 2004, Simulation study on the performance improvement of a transcritical carbon dioxide cycle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 158-166
  21. Hwang, Y. S., Lee, D. Y. and Park, B. C., 2004, Theoretical analysis on the heat and mass transfer in a sorption cool pad, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 167-174
  22. Yoo, S. Y., Kwon, H. K. and Kim, K.Y., 2004, Performance analysis of water/air direct contact air conditioning system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp.175-183
  23. Seo, J. U. and Huh, J. H., 2004, Energy performance evaluation of VA V system through various operating strategies in office buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp. 184-193
  24. Kim, J. K. and Cho, K. N., 2004, Effect of wavy flow of vertical falling film on the absorption performance, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.2, pp.194-202
  25. Lee, D.-Y., Baik, Y.-J. and Kim, Y., 2004, Cooling enhancement potential of an air-cooled condenser by evaporative cooling, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 203-210
  26. Kim, S. H., Kim, S. Y. and Kang, B. H., 2004, Effect of solid insert on thermal stratification on a side-heated natural convection enclosure, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 211-217
  27. Min, C. K, Cho, J. P., Oh, W. K. and Kim, N. H., 2004, Heat transfer and pressure drop characteristics of heat exchanges having plain fins under dry and wt conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 218-229
  28. Kim, C.-D. and Lee, J., 2004, Effects on refrigerant maldistribution on the performance of evaporator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp.230-240
  29. Kim, H. J., An, K. J. and Kim, C. W., 2004, Optimum design of $CO_2$ scroll compressor for heat pump water heater, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 241-249
  30. Hong, J. K., 2004, Experimental study on the irradiation and surface sterilization effect of ultra violet ray in air conditioning system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 250-257
  31. Kim, J. H., Chung, N. K., Kim, S., Kim, C. O. and Kang, S. H., 2004, The effects of additives on the thermal properties of a clathrate compound (I), Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp.258-264
  32. Moon, J. S., Kang, S. Y., Lee, S. C., Yoo, H. and Lee, J. H., 2004, Analysis of air flow rate distribution for the bathroom exhaust system in high-rise buildings using T-method, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 265-272
  33. Jun, Y. D. and Lee, K. B., 2004, Performance test of a multi-riser fluidized bed heat exchanger for flue gas heat recovery, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp.273-279
  34. Kweon, Y. C., Jeong, J. H., Chang, K. S., Hong, K. S. and Jin, S., 2004, Heat transfer performance of individual rows in fin-tube heat exchangers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 280-286
  35. Lee, J. H., Jung, E. K. and Yun, J. H., 2004, Experimental performance study of the bubble pump for the diffusion absorption refrigerating system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp.287-292
  36. Kim, H. R., Park, K. and Choi, D. H., 2004, Numerical shape optimization for plate-fin type heat sink, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 293-302
  37. Lee, S. C., 2004, Evaluation on thermal environment installed ventilating fans in the rotunda at new national museum of Korea, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.3, pp. 303-309
  38. Kwon, Y. C., Ko, K. W., Jin, E. S. and Huh, S. H., 2004, Experimental study on cooling characteristics of multi-air conditioner using inverter scroll compressor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.16, No.4, pp.311-317
  39. Ahn, Y. C., Hwang, P. J. and Lee, J. K., 2004, A study on an ion wind created by a wire electrode and parallel plates assembly, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp. 318-323
  40. Jin, D. X., Kim, S. Y., Lee, D. Y. and Lee, Y. P., 2004, PIV investigations of the flow mixing enhancement by pulsatile flow in a grooved channel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.324-331
  41. Sim, Y. H., Park, Y. C. and Bay, Y. M., 2004, An analysis of the patent for highly efficient absorption refrigeration system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.332-339
  42. Jung, G., Park, Y. C. and Oh, S. K., 2004, A study on performance characteristics of heat exchanger for heat pump with R410A refrigerant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.340-348
  43. Sung, S. K., Suh, S. H. and Roh, H. W., 2004, Analyses of fouling mechanism using visualization techniques in a lab-scale plate-type heat exchanging system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.349-354
  44. Kim, N. H., Cho, J. P. and Youn, B., 2004, An experimental investigation on the airside performance of fin-and-tube heat exchangers having sinusoidal wave fins, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.355-367
  45. Kim, S.-K., 2004, An experimental investigation on flow field in a pipe with sinusoid-dally wavy surface by PIV, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.368-373
  46. Chung, J. D., Park, J. H. and Cho, S. H., 2004, Effect of diffuser shape on the performance of water-chilled heat storage, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp.374-383
  47. Lee, J. S., 2004, Demonstrative experiments on the magnetocaloric effect of gadolinium, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp. 383-389
  48. Jung, J., Nam, K., Jeong, S. and Jeong, E. S., 2004, Pressure measurement in double inlet pulse tube refrigerator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.4, pp.390-396
  49. Kim, C.-D., Kang, S.-H., Park, I.-H. and Lee, J., 2004, Effects of relative humidity on the evaporator pressure drop, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp.397-407
  50. Han, S. K., Kang, B. H. and Lee, B. J., 2004, Prediction of oil lifetime due to overheating of oil and bearing housing in a pump, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 408-413
  51. Choi, Y. C., Kang, B. H. and Kim, S., 2004, An experimental study on heat transfer and pressure drop characteristics during supercritical process of carbon dioxide in a horizontal tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 414-420
  52. Kim, O. B., Lee, M. K., Yeo, M. S. and Kim, K. W., 2004, A study of the individual room control of radiant floor heating system in apartment buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp.421-429
  53. Bae, K. Y., Lee, K. S., Jeong, H. M., Chung, H. S. and Chung, H. T., 2004, A study on the thermal and electrical characteristics with manufacture of the heating element by using carbon with bar type, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp.430-437
  54. Yun, H. J., Kim, S. S. and Kang, Y. T., 2004, Performance analysis of a 5RT air-cooled $NH_3-H_2O$ absorption chiller with the variations of heat input and ambient temperature, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 438-443
  55. Park, K-H., Seo, Y.-H., Park, K.- J. and Jung, D., 2004, Flow condensation heat transfer coefficients of R22 alternative refrigerants in plain and microfin tubes of 6.0 mm inside diameter, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 444-451
  56. Lee, J. H., Kim, B. G. and Lee, K. W., 2004, Effect of outdoor temperature on the refrigerant behavior in the compressor of a heat pump operating at heating mode, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 452-458
  57. Lee, B. J., Chung, D. Y., Lee, S. and Hong, H., 2004, Analysis of heating energy in a Korean-style apartment building 2: the difference according to heating type, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp.459-466
  58. Riu, K. J., Park, C. W. and Jang, C. S., 2004, Effects on surface roughness on evaporation cooling of single water droplet in radiative fields, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp.467-474
  59. Shin, D. H., Choi, C. H. and Jeong, K. S., 2004, Wafer motion control of clean tube system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 475-481
  60. Lee, J. W. and Lim, J. M., 2004, The experimental study on the efficiency of ventilation of Korean paper (hanji), Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp.482-489
  61. Yoon, Y. H. and Kim, K. H., 2004, Study on the experiment and numerical computation of forced convection heat transfer around circular cylinder in a rectangular duct, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 490-498
  62. Chung, N. K., Kim, J. H., Kim, C. O. and Kim, K I., 2004, The effects of additives on the thermal properties of a clathrate compound (II), Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.5, pp. 499-505
  63. Oh, M. K., Lee, B. J., Hong, H. K. and Kang, Y. T., 2004, Life-cycle cost analysis of solution transportation absorption system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.506-513
  64. Lee, C. G., Lee, S. K., Lee, K. B., Rhi, S. H. and Kim, J. H., 2004, Study on heat recovery system using waste biomass, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.514-521
  65. Bae, D., Ha, J., Yoo, G. and Jung, D., 2004, A study of external condensation heat transfer of flammable refrigerants, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.522-529
  66. Yoon, S. H., Cho, E. S. and Kim, M. S., 2004, Characteristics of evaporative heat transfer and pressure drop of carbon dioxide and correlation development near the critical point, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp. 530-537
  67. Yoon, S. H., Kim, J. H. and Kim, M. S., 2004, Experimental studies on heat transfer and pressure drop characteristics during gas cooling process of carbon dioxide in the supercritical region, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.538-545
  68. Lee, E. S., 2004, Investigation of local convective heat transfer around a circular cylinder in cross flow of air, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp. 546-555
  69. Choi, B. S., Kim, J. H., Kang, Y. T. and Hong, H., 2004, Verification experiment and analysis for 6 kW solar water heating system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 556-565
  70. Lee, J. W., Lee, D. Y. and Kang, B. H., 2004, Cycle simulation of a desiccant cooling system with a regenerative evaporative cooler, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp. 566-573
  71. Cho, Y. H., Seok, H. T., Yeo, M. S. and Kim, K. W., 2004, A study on the operation strategy of radiant floor cooling in apartment buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.574-583
  72. Kang, H. C. and Kang, M. C., 2004, Forced convection correlation for single circular fin-tube heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.584-588
  73. Seo, Y.-H., Park, K.-J. and Jung, D., 2004, A comparison of flow condensation HTCs of R22 alternatives in the multi-channel tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp. 589-598
  74. Lee, J. W. and Lim, J. M., 2004, The experimental study on a effect of Korean paper (hanji) on indoor humidity control, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp.599-607
  75. Ihm, P. C., 2004, Artificial lighting energy saving by daylighting in office building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.6, pp. 608-613
  76. Yang, W. J., Kim, T. S. and Kim, J. H., 2004, Performance characteristics analysis of gas turbine-pressurized SOFC hybrid systems, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp. 615-622
  77. Shin, J. Y., Son, Y. S., Kim, S. M. and Lee, D. Y., 2004, Experiments on the heat transfer and pressure drop characteristics of a channel with pin-fin array, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp.623-629
  78. Lee, S. D., Park, M. S., Chung, J. E. and Choi, Y. S., 2004, Study on the performance characteristics with the height of s regenerator and dehumidifier for liquid desiccant dehumidification system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp.630-638
  79. Lee, H. S., Kim, J. D. and Yoon, J. I., 2004, Condensing heat transfer characteristics of propylene refrigerant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp.639-644
  80. Lee, M.-K., Kim, Y., Chang, Y.-S. and Kim, Y., 2004, Performance analysis of fin-tube evaporator for carbon dioxide, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp.645-651
  81. Kim, S.-D., Song, J.-H. and Lee, H., 2004, Estimation of train-induced wind generated by train operation in subway tunnels., Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp. 652-657
  82. Ihm, P. C., 2004, An approach to model ground-coupled building foundation for energy simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp. 658-666
  83. Lee, J. S. and Lee, K. S., 2004, Frosting behavior on the plate of thermally conductive plastic, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, 667-672
  84. Kim, D. J. and Lee, K. W., 2004, Cost accounting of electricity and heat on combined cycle cogeneration, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.7, pp.673-682
  85. Kang, H. S. and Kim, Y. J., 2004, Thermal performance analysis of a modified rectangular fin, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp.683-690
  86. Suh, J. S., Chung, S. W. and Chung, K. Y., 2004, An experimental study on the thermal performance of sinusoidal axially grooved heat pipe, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol.16, pp.691-697
  87. Yoon, P.-H., Kang, Y.-T. and Jeong, J., 2004, Measurement of heat transfer coefficient in a flooded evaporator through Wilson plot method, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp. 698-706
  88. Jeong, J., Kim, D. H. and Kim, C. N., 2004, A study on the flow characteristics of piezoelectric micropumps with different numerical models, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp.707-713
  89. Kim, J., Kang, Y. T. and Choi, C. K., 2004, Analysis of convective instability induced by buoyancy and heat transfer characteristics for natural convection in nanofluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp. 714-719
  90. Kim J., Kang, Y. T. and Choi, C. K., 2004, Analysis of convective instability induced by buoyancy and heat transfer characteristics for natureal convection in nanofluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp, 714-719
  91. Riu, K. J., Park, C. W., Jang, C. S. and Kim, H. W., 2004, Cooling characteristics of wing fin heat sink, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp.728-740
  92. Kim, J.-S., Im, Y.-B. and Cho, W.-H., 2004, The experimental study on cooling-heating system using thermoelectric module and parallel flow type oscillating heat pipe, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp.741-747
  93. Choo, W.-H. and Bang, K.-H., 2004, An experimental study of flow boiling heat transfer inside small-diameter round tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp. 748-755
  94. Kwon, I.-W. and Ha, O.-N., 2004, The study on performance characteristics of superheating the suction vapor in $NH_3$ refrigeration system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp.756-761
  95. Woo, S. J., 2004, A study on design decision of qualitative design factors in selecting of HVAC type for building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp.762-769
  96. Lee, K. B. and Jun, Y. D., 2004, Fouling reduction characteristics of a fluidized bed heat exchanger for flue gas heat recovery, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.8, pp. 770-777
  97. Han, D. W., Shin, J. Y., Son, Y. S. and Song, C. S., 2004, Off-design performance of a plate heat exchanger: analysis and experiment, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.779-787
  98. Shin, J. Y., Son, Y. S. and Kim, S. M., 2004, Experiment on the cooling characteristics of protruding heat sources in a channel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.788-795
  99. Choi, S.-H., Lee, K.-S., Kim, I.-K. and Lee, D.-H., 2004, Analysis of the condenser stack effect in a high-rise apartment building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp. 796-803
  100. Kim, W. K., Kim, C. S. and Choi, Y. D., 2004, Numerical study on the turbulent flow in the $180^{\circ}$ bends increasing cross-sectional aspect ratio, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp. 804-810
  101. Lee, G. B., Lee, D. Y. and Kim, M. S., 2004, Development of a linearized model and verification of the exact solution for the analysis of a desiccant dehumidifier, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp. 811-819
  102. Moon, I. H. and Hwang, Y. K., 2004, Evaluation of a propulsion force coefficient for transportation of wafers in an air levitation system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp. 820-827
  103. Cho, H., Cho, K., Youn, B., Kim, Y. S. and Kim, J. H., 2004, Two-phase flow distribution, phase separation and pressure drop in multi-microchannel tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.828-837
  104. Han, D. Y. and Yoon, J. W., 2004, Dynamic model of the road tunnel pollution by neural networks, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp. 838-844
  105. Park, J.-H. and Kim, Y.-S., 2004, Study on evaporation heat transfer of R-134a, R-407C, and R-410A in the oblong shell and plate heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.845-854
  106. Park, J.-H. and Kim, Y.-S., 2004, Study on evaporation pressure drop of R-134a, R-407C, and R-410A in the oblong shell and plate heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.855-862
  107. Kim, N. J. and Kim, J. B., 2004, Study on the dissolution characteristics of liquid $CO_2$ released by fixed pipeline, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.863-871
  108. Han, D. Y. and Kim, J., 2004, An experimental study on the rule based fault detection and diagnosis system for a constant air volume air handling unit, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp.872-880
  109. Han, D. Y. and Kim, J., 2004, Optimal control algorithm for the dual source chiller air conditioning system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No.9, pp. 881-888
  110. Kang, B. H., Lee, J. H. and Kim, H. Y., 2004, An experimental study on the cooling characteristics of an infrared detector cryochamber, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 889-894
  111. Choi, J. M., Kim, Y., Kwak, J. S. and Kwon, B. C., 2004, A generalized flow model and flow charts for predicting mass flow rate through short tube orifices, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.895-900
  112. Kim, Y. J., Ha, B. K., Jeong, S. H., Moon, S. C. and Yoo, J. S., 2004, A study on the collection characteristics of a moving electrode electrostatic precipitator - I. Effect of collection plate velocity, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 901-907
  113. Kim, Y. J., Ha, B. K., Jeong, S. H., Hong, W. S. and Yoo, J. S., 2004, A study on the collection characteristics of a moving electrode electrostatic precipitator - II. Effect of wave form of pulse energization and dust concentration, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.908-913
  114. Kim, S. S. and Kim, Y. I., 2004, Measurement and analysis of energy consumption of HVAC equipment of a research building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 914-922
  115. Nam, J. H., Song, C. S. and Kim, C.-J., 2004, Development of freeze drying analysis program using fixed grid, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.923-931
  116. Cho, S. H., Hong, Y. J., Yang, H. C. and Ahn, B. C., 2004, An experimental study on multi -fault detection and diagnosis analysis of HVAC system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.932-941
  117. Seong, H.-C. and Kim, K.-H., 2004, Effect of radiation on laminar film boiling of binary mixtures, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.942-951
  118. Lee, S. D., Park, M. S., Chung, J. E. and Choi, Y. S., 2004, Study on the energy efficiency improvement of hybrid dehumidification air conditioning system compared with refrigeration system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.952-959
  119. Leigh, S. B. and Won, J. S., 2004, An analysis of demand for environmental controls on different residential building types, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 960-968
  120. Jin, J. H. and Chung, S. T., 2004, Design and implementation of optimal control algorithms for building energy management, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 969-976
  121. Kim, B. J., Jeong, E. S. and Sohn, B. H., 2004, Boiling heat transfer in a narrow rectangular channel with offset strip fins, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 977-983
  122. Son, W. T. and Lee, S., 2004, Study on thermal property in urban area - Part 1: Experimental analysis for predicting methodology of thermal property in urban area, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp. 984-989
  123. Kim, B. J., 2004, Dynamic analysis of an ammonia-water absorption chiller, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 10, pp.990-998
  124. Yoo, J. S. and Kim, Y. J., 2004, Thermal convection between two horizontal plates with small amplitude non-uniform temperatures, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp.999-1005
  125. Yang, W. J., Kim, T. S. and Kim, J. H., 2004, Analysis of performance characteristics of gas turbine-pressurized SOFC hybrid systems considering limiting design factors, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp. 1013-1020
  126. Oh, K. S. and Kim, T. S., 2004, Effect of system configuration on design performance of atmospheric pressure MCFC/gas turbine hybrid systems, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp.1021-1027
  127. Kim, K. M. and Park, K. W., 2004, Variation of pressure loss and IPF flowing ice slurry in straight tube inclined to various angle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp. 1028-1034
  128. Han, D. Y. and Yoon, J. W., 2004, A tunnel ventilation control algorithm by using CO density prediction algorithm, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp.1035-1043
  129. Lee, Y. S., Kim, J. R., Chang, K. C. and Baik, Y. J., 2004, Technology of waste heat recovery using heat pipe heat exchanger for industrial practice, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 1044-1050
  130. Kang, I. S., Choi, D. K. and Kim, T. Y., 2004, Experimental study on the two phase thermosyphone loop with parallel connected multiple evaporators under partial load and low temperature operating condition, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp.1051-1059
  131. Park, Y. and Park, J. I., 2004, A study on the simplified economics evaluation method for selecting a heat source system at the pre-design phase, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp.1060-1067
  132. Cho, S. H., Yang, S. H. and Yang, H. C., 2004, A study of optimum control in building HVAC system using reinforce signal, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp, 1068-1076
  133. Chung, J. D., Park J. H. and Cho, S. W., 2004, Effect of design factors on the performance of stratified thermal storage tank, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 1077-1084
  134. Lee, D. W. and Yoo, S. Y., 2004, A numerical study for performance of automotive HVAC system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp.1084-1091
  135. Son, W. T. and Lee, S., 2004, Study on fresh air load reduction system by using geothermal energy: effect on thermal characteristic and air pattern of system by opening configuration, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 11, pp. 1092-1100
  136. Lee, J. S. and Hong, J. H, 2004, Experimental study on a rotary magnetic refrigeration device, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp. 1101-1106
  137. Lee, K. W., Chun, W. P., Lee, W. H. and Park, K. H., 2004, A Theoretical analysis on the factors affecting the operation of loop heat pipe, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp. 1107-1116
  138. Baik, Y. J., Park, S. R., Chang, K. C. and Ra, H. S., 2004, Simulation of comperssion/absorption hybrid heat pump system using industrial wastewater heat source, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 16, pp.1117-1125
  139. Son, C.-H., Lee, D.-G., Kim, Y.-L. and Oh, H.-K., 2004, Evaporative heat transfer characteristics of carbon dioxide in a horizontal tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp. 1134-1139
  140. Kim, S. H., Noh, K. C. and Oh, M. D., 2004, Evaluation of the indoor thermal comfort in consideration of the solar radiation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp, 1140-1148
  141. Ahn, S. W., Bae, S. T., Kim, M. H., Lee, B. C. and Lee, Y. P., 2004, Heat transfer in a vertical type fluidized bed heat exchange with corrugated tubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp.1149-1155
  142. Park, K. and Choi, D. H., 2004, Optimal design of a heat sink using the sequential approximate optimization algorithm, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp.1156-1166
  143. Lee, J. and Kim, M. H., 2004, Analysis of the gravity effect on the distribution of refrigerant flow in a multi-circuit condenser, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp. 1167-1174
  144. Woo, J. S., Kim, D. K and Lee, S. K, 2004, A study on the heating performance of ground source heat pump system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol.16, pp. 1175-1182
  145. Kim, J. H., Chung, N. K., Kim, S. H., Kim, C. O. and Kang, S. H., 2004, The effects of an additive on the thermal properties of a clathrate compound (III) - The case of TMA clathrate with acetone, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp. 1183-1189
  146. Son, W. T. and Lee, S., 2004, Study on thermal property in urban area-quantitative estimation of heat island in urban area using the simple urban canopy model, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.16, No. 12, pp.1190-1196
  147. Han, H. T. and Kim, M. K., 2004, An experimental study on air leakage and heat transfer characteristics of a rotary-type heat recovery ventilator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.16, No. 12, pp.1197-1203
  148. Cho, Y. J., Kang, S. Y., Moon, J. S. and Lee, J. H., 2004, ADPI characteristics of line diffuser in a room with perimetric heating load, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp. 1204-1211
  149. Chung, N. K., Kim, J. H. and Kim, C.O., 2004, The effects of an additive on the thermal properties of a clathrate compound (IV) - The case of TMA clathrate with surfactant, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.16, No. 12, pp. 1212-1217
  150. Son, W. T. and Lee, S., 2004, Study on fresh air load reduction system by using geothermal energy, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 12, pp. 1218-1226
  151. Won, K. H., Kwak, R. Y. and Huh, J. H., 2004, Evaluation of energy consumption of HVAC system for air filter pressure difference change in commercial buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.16, No. 12, pp. 1227-1233
  152. Kang, H. D., Kim, W. J. and Seo, T. B., 2005, Analysis of heat transfer characteristics of internal heat exchanger for $CO_2$ refrigerator using the Hardy-Cross method, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No.1, pp.1-7
  153. Kim, Y. J., Kim, C. S. and Hwang, Y. K., 2005, A study on the helical flow of newtonian and non-newtonian fluid, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No. 1, pp.8-15
  154. Choi, B. S., Lee, B. J., Kang, C. D. and Hong, H., 2005, Verification experiment and analysis for 6 kW solar water heating system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 16-24
  155. Lee, D. Y., Lee, J. W. and Kang, B. H., 2005, An experimental study on the effects of porous layer treatment on evaporative cooling of an inclined surface, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No.1, pp.25-32
  156. Kim, D. H., Jeong, J. and Kim, C. N., 2005, A numerical study on the performance characteristics of a piezoelectric mircopump for different inlet and outlet positions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No.1, pp.33-38
  157. Ju, J. D., Bae, K. S., Hwang, Y. K., Lee, Y. Y., Jeong, G. H. and Oh, S. K., 2005, An experimental study on the performance of a heat pump for the cold climate, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 39-46
  158. Kim, M. and Kim, M. S., 2005, Studies on the performance variation of a variable speed vapor compression system under fault and its detection and diagnosis, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.1, pp.47-55
  159. Kwon, Y. I., Hwang, K. H., Chung, B. Y. and Lee, G. G., 2005, A study on the evaluation of air change efficiency of multi-air-conditioner with ventilation system for heating season, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp.56-61
  160. Lee, J.-S. and Lee, K.-S., 2005, Heat transfer performance of evaporator used in a domestic refrigerator/freezer under frosting condition, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.1, pp.62-70
  161. Sohn, B. H., Cho, C. S., Shin, H. J. and An, H. J., 2005, Cooling and heating performance evaluation of a GSHP system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 71-81
  162. Park, B. Y. and Chung, K. S., 2005, Characteristics of energy consumption in an office located in Seoul, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.1, pp.82-87
  163. Ahn, B. C. and Lee, T. W., 2005, Strategy of energy saving and thermal environment improvement for intermittent heating system in apartment buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.1, pp.88-93
  164. Shin, J.-J., Lee, H.-S., Kim, J.-M., Min, J.-K. and Oh, S., 2005, Numerical and experimental analysis of desing parameters of a slim room air-conditioner, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 95-100
  165. Chang, Y. S., Lee, M. K., Ahn, Y. S. and Kim, Y., 2005, An experimental study on the performance of outdoor heat exchanger for heat pump using $CO_2$, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp.101-109
  166. Choi, H. M., Monji, H. and Matsui, G., 2005, Characterization of interaction between two particles/bubbles flow with moving object flow image analyzer system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp.110-116
  167. Yoo, S. Y., Chung, M. H., Kim, K. H. and Lee, J. M., 2005, An experimental study on the performance of plastic plate heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 117-124
  168. Kim, J. H., Chung, N. K, Kim, S. and Kim, C. O., 2005, The effects of additives on the cooling characteristic of a clathrate compound, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 3, pp. 125-130
  169. Han, K. and Cho, D. H., 2005, A study on the performance of boiling heat transfer of two-phase closed thermosyphons with various helical grooves, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 131-139
  170. Ahn, B. C., Choi, S. G. and Cho, S. H., 2005, On-line optimal control technology for central heating system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 140-146
  171. Han, D. Y. and Yoon, J. W., 2005, A cascade control algorithm for the CO level control of a long road tunnel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 147-155
  172. Ahn, Y. H., Kang, B. H., Kim, S. H. and Lee, D. Y., 2005, The operation characteristics and cost analysis of an ice thermal storage system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 156-164
  173. Han, S. K. and Kang, B. H., 2005, Effects of flow resonance on heat transfer enhancement and pressure drop in a plate heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp.165-172
  174. Sohn, B. H., Shin, H. J. and An, H. J., 2005, Evalustion of thermal conductivity for grout/soil formation using thermal response test and parameter estimation models, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 173-182
  175. Seung, H., Hong, H. and Kang, C., 2005, Effect of the adhesion of ice slurry by the characteristic of cooling surface, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp.183-190
  176. Hwang, H. J, and Choi, H. G., 2005, Numerical analysis of optimum air-layer thickness in a double glazing window, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.2, pp. 191-199
  177. Hwang, Y. J., Cho, E. J., Chung, B. Y. and Lee, G. G., 2005, The experimental study on performance improvement under frost conditions of the heat pump with corrugate shaped fin and two comperssors, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp. 201-208
  178. Cho, H., Ryu, C. and Kim. Y, 2005, Experimental study on the cooling performance of a variable speed $CO_2$ cycle with internal heat exchanger and electronic expansion valve, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp. 209-215
  179. Choi, J. M. and Kim, Y., 2005, Effects of fin conduction and superheat unbalance on the performance of an evaporator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp.216-222
  180. Lee, Y., Peck, J. H., Kang, C. and Hong, H., 2005, Improving the precision for the T-history method for latent heat measurements of low melting temperature PCMs, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp. 223-231
  181. Lee, B. J., Kang, C. D., Lee, S. R. and Hong H., 2005, Verification experiment and analysis for 6 kW solar water heating system (Part 4: comparing economics and raising competitiveness), Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp.232-242
  182. Shin, Y. G. and Kim, Y. I., 2005, Dynamics modeling of a GHP in cooling mode for development of control algorithm, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, PP. 243-249
  183. Cho, Y. K., Kim, J. K., Oh, M. K. and Kang, Y. T., 2005, Type 2 absorption cycle to transport energy in the long distance for district cooling application, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp.250-255
  184. Kim, J., Jung, C. W., Kang, Y. T. and Choi, C. K., 2005, Short effect on the convective instability binary nanofluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp.256-261
  185. Ahn, Y. C. and Lee, J. K., 2005, Modeling of the air-side particulate fouling in finned tube heat exchangers of air conditioners using accelerated particle-loading system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp. 262-267
  186. Kang, S. Y., Lee, T. G., Ryu, I. K. and Lee, J. H., 2005, Performance of an axial turbo fan by revision of impeller pitch angle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp. 268-276
  187. Lee, J. W. and Hwang, H. Y., 2005, An investigation on the effect of duration of sunshine on the heating energy of apartment houses, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.3, pp. 277-284
  188. Lee, G. S., 2005, Design and energy analysis for a combined cycle using LNG cold/hot energy, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.285-296
  189. Ha, O.-K., Kwon, I.-W., Jeon, S.-S., Lee, S.-J., Jung, S.-T., Ha, K.-S., Yun, K.-S. and Lee, J.-I., 2005, The study on performance characteristics of $NH_3$ refrigeration system for various degree of superheat - Part II: the change of heat exchanger type, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.297-302
  190. Lee, E.-S., 2005, A study of conjugate laminar film condensation on a flat plate, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp. 303-311
  191. Jung, J. Y., Kim, J. K. and Kang, Y. T., 2005, Enhancement of $NH_3$ bubble absorption performance in binary nanofluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp. 312-317
  192. Park, J. I., Jeong, J., Lee, Y. S. and Kang, Y. T., 2005, Friction and heat transfer characteristics of enhanced tubes with internal ribs, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 4, pp.318-324
  193. Kim, H. J., Park, I. S. and Rha, P. C., 2005, Performance test of scroll expander for micro-power generation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.325-332
  194. Kim, B. G., Choi, H. G., Yong, H. T. and Lee, M. H., 2005, Horizontal air-jet effect on the natural convection around a range-hood system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.333-340
  195. Kim, J. H., Choi, B. S., Hong, H. and Kim, Y. S., 2005, Experimental verification for a spiral-jacketed storage tank applied to solar thermal system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol.17, No.4, pp. 341-346
  196. Cho, S. W., 2005, The study on thermal characteristic of the balcony with natural ventilation system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.347-354
  197. Jin, D. X., Lee, D. Y. and Lee, Y. P., 2005, Simultaneous measurement of fluid velocity and particle velocity in a particle-containing fluid flow, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.355-363
  198. Lim, H. J., Kong, H. J., Song, Y. S. and Park, S. K., 2005, Thermal conductivity measurement of grouting materials for geothermal heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.364-369
  199. Park, B. Y., Ham, H. D. and Sohn, J. Y., 2005, Evaluation of indoor thermal environment according to air-barrier air conditioning system in perimeter zone, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.370-376
  200. Sim, Y. H., Youn, Y. and Park, Y. C., 2005, A numerical study on heat transfer in a reciprocating compressor for a domestic refrigerator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.4, pp.377-385
  201. Lee, J. H., Kim, B. J., Cho, D. J. and Yoon, S. J., 2005, Effect of a variation of a main duct area on flow distribution of each branch, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 4, pp. 386-395
  202. Kim, S. H. and Park, J. I., 2005, Evaluation of indoor air environment by changing diffuser location and air temperature with under floor air conditioning system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.397-403
  203. Kim, D. G. and Kum, J. S., 2005, Evaluatoin of thermal comfort during sleeping in summer- Part 1: on results of questionnaire before and after sleep, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.404-409
  204. Cho, H., Ryu, C., Kim, Y. and Sim, Y., 2005, Effects of refrigerant charge amount on the cooling performance of a transcritical $CO_2$ cycle, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.410-417
  205. Sim, Y-H., Youn, Y. and Park, Y. C., 2005, A study on efficiency enhancement in a reciprocating compressor for a domestic refrigerator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.418-426
  206. Jung, J. H. and Shin, Y. G., 2005, An experimental study on thermal storage performance of an air conditioning system with slab thermal storage, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.427-435
  207. Shin, Y.-H., Oh, W.-K, Park, K.-H., Kim, Y. and Shin, Y., 2005, Measurement and analysis of showcase field data, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.436-443
  208. Han, D. Y. and Kim, J., 2005, Fault detection and diagnosis of a constant volume air handling unit by a fuzzy algorithm, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp. 444-451
  209. Chang, Y. S. and Yun, W. N., 2005, An experimental study on the frost prevention using micro liquid film of an antifreezing solution, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp. 459-467
  210. Cha, Y. H. and Yee, J.J. 2005, The proposal of a new drainage system without incline of piping and experiment on drainage flow characteristics, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.452-458
  211. Yu, H. K., Park, J. C. and Lee, E. K., 2005, A study on a proper reduction process of indoor air pollutants in newly-constructed multi-family houses, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp. 468-476
  212. Chung, C. Y. and Bae, N. R., 2005, A study on acceptable thermal comfort zone and resident behavior of operating cooling devices in apartments, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.477-486
  213. Kim, C. N. and Lee, Y. G., 2005, A study on concentration change of volatile organic compounds; VOCs by using mock-up test, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp. 487-495
  214. Kim, S. M., Park, B. Y. and Sohn, J. Y., 2005, Evaluation of the performance and the energy consumption characteristics of heat recovery ventilators in apartments, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.5, pp.496-504
  215. Pang, S. K., Sohn, J. Y. and Ahn, B. W., 2005, Prediction of the concentration decay of volatile organic compounds under different air change rates and loading factor conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No:6, pp.505-513
  216. Bae, S. T., Ahn, S. W., Kim, M. H., Lee, D. H. and Kang, H. K., 2005, Effct of number of heating walls on heat transfer in ribbed rectangular channel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp.514-520
  217. Park, I. H., Yoon, H. K, Park, J. T., Chang, K. C. and Lee, Y. S., 2005, A study on the potential energy reserve amount of domestic river water as unutilized energy resource, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 521-528
  218. Yun, R., Kim, Y., Kim, S. and Choi, J. M., 2005, Experimental study on the heat transfer characteristics of spiral fin-tube heat exchangers, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp.529-535
  219. Lee, J. H. and Kim, T. S., 2005, Design performance analysis of micro gas turbine-organic rankine cycle combined system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 536-543
  220. Kim, D., Han, D. S., Jeong, S., Hur, N. and Yoon, S. J., 2005, CFD analysis on the flow characteristics of diffuser/nozzles for micro-pumps, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 6, pp. 544-551
  221. Kim, H. and Jeong, S., 2005, An experimental study on performance of the inertance pulse tube refrigerator using a small compressor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp.552-559
  222. Kim, D. J. and Lee, K. W., 2005, Cost accounting of heat and electricity of a combined cycle cogeneration system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, No.6, pp. 560-568
  223. Jang, I. H., Hwang, S. D. and Cho, H. H., 2005, Effects of aspect ratio on local heat/mass transfer in wavy duct. Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp.569-580
  224. Choi, S. G. and Hong, J. K., 2005, The study on the performance estimation of UVC air sterilizer for preventing transmission of air borne contagion, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp.581-586
  225. Oh, S. J., 2005, Optimal design variables of a parallel flow heat exchanger by using a desirability function approach, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp.587-595
  226. Park, I. H., Yoon, H. K., Chang, K. C., Park, J. T. and Park, S. R., 2005, Life-cycle analysis of the river water unutilized energy system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp.596-604
  227. Byun, K. H., 2005, Nocturnal radiant cooling experiment by a plate viewing the sky, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.6, pp. 605-610
  228. Lee, G. B., Kim, M. S. and Lee, D. Y., 2005, Derivation and analysis of dimensionless parameters dominating the dehumidification characteristics of a desiccant rotor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp.611-619
  229. Choi, D. H., Jo, J. H., Seok, H. T., Yeo, M. S. and Kim, K. W., 2005, Planning the blind position considering thermal performance in the intermediate space of doble-skin facade, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp. 620-628
  230. Cho, S. W., Park, M. Y. and Im, Y. B., 2005, A study on the airflow near the cold heat source using CFD in merchandising store, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp. 629-634
  231. Park, K. W. and Kim, K. M., 2005, Influence of velocity on pressure drop of flowing ice slurry in elbow and its continued inclined tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 7, pp.635-641
  232. Jeong, J. and Kim, C. N., 2005, A numerical study on the thermopneumatic and flow characteristics of diffuser-nozzle based thermopneumatic micropumps, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp.642-648
  233. Park, K.-J., Lee, K.-Y. and Jung, D., 2005, Flow condensation heat transfer coefficients of R22, R410A and propane in aluminium multi-channel tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp, 649-658
  234. Kim, Y., Seo, T. B. and Kang, Y. H., 2005, Thermal performance variations of glass evacuated tube solar collectors depending on the absorber shape and the incidence angle of solar ray, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp.659-668
  235. Kim, J. H., Kim, S. S., Yang, I. H. and Kim, K. W., 2005, Development of the air-conditioning unit for workspace integrated units, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp. 669-680
  236. Lee, K.-B., Lee, H.-S., Kim, J.-D. and Yoon, J.-I., 2005, Characteristic on evaporating heat transfer and pressure drop of HCs refrigerants, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 7, pp, 681-687
  237. Yee, J. J., Lee, J. H. and Lee, S. M., 2005, IAQ field survey in an apartment housing equiped for heat recovery ventilation system with air cleaning function, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.7, pp.688-693
  238. Sohn, B. H., Shin, H. J. and Park, S. K., 2005, Evaluation of effective thermal conductivity and thermal resistance in ground heat exchanger boreholes, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp.695-703
  239. Kim, S. S., Lee, S. W., Kim, J. H., Yang, I. H. and Kim, K. W., 2005, A study on the development of the workspace integrated units, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 8, pp.704-713
  240. Yim, S. H., Shin, C. H. and Cho, H. H., 2005, Effect of roughness on two-phase flow heat transfer by confined liquid impinging jet, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp, 714-721
  241. Park, Y. W., Yoo, H. S. and Hong, H., 2005, Analysis of heating energy in a Korean-style apartment building 3: the effect of room condition settings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp.722-728
  242. Yoo, G.-S., Hwang, J.-H., Park, K.-J. and Jung, D., 2005, External condensation heat transfer coefficients of R22 alternative refrigerants and R134a according to the saturation vapor temperature change on a smooth tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp.729-735
  243. Jang, J. S., Noh, K. C. and Oh, M. D., 2005, Study on the relationship between indoor $CO_2$ concentration and local mean air-age in the lecture room with system air-conditioner and ventilation unit for cooling loads, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp. 736-745
  244. Kwon, O.-K., Yun, J.-H., Joo, Y.-J., Kim, Y. and Kim, J.-H., 2005, An experimental study on the heat and mass transfer of adsorption chiller, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp.746-753
  245. Kim, H. J., Cho, K. M. and Ko, W., 2005, Performance analysis of an orbiter air compressor, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp, 754-763
  246. Jeong, E. S., 2005, Optimization of conduction-cooled Peltier current leads, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp.764-771
  247. Cho, P.-J., Lee, S.-K., Youn, Y. and Ko, H. S., 2005, Analysis of oil behavior inside upper part of rotary compressor using visualization technique, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp.772-779
  248. Han, D. and Ryoo, B., 2005, The fault detection of an air-conditioning system by using a residual input RBF neural network, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.8, pp. 780-788
  249. Yang, J. S., 2005, Numerical analysis on the flow field and heat transfer characteristics of longitudinal vortices in turbulent boundary layer - on the common flow down - , Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp. 789-798
  250. Yang, J. S., 2005, Numerical analysis on the flow field and heat transfer characteristics of longitudinal vortices in turbulent boundary layer - on the common flow up -, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp. 799-807
  251. Choi, J. M., Kim, Y. C., Cheon, D. W., Shim, Y. H., Lee, S. H. and Kwak, J. S., 2005, An analysis of the patents for heat pumps, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 808-815
  252. Lee, S.-M., Lee, J.-D. and Park, B.-D., 2005, Condensing performance evaluation in smooth and micro-fin tubes for natural mixture refrigerant (propane/butane), Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp.816-823
  253. Kim, H., Sohn, W.-S. and Choi, K.-S., 2005, Study on the performance optimization of commercial metal hydride refrigerator powered by exhaust gas from micro gas turbine, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 9, pp. 824-829
  254. Kim, S. K. and Cho, K. N., 2005, Study on the optimization of absorption performance of the vertical tube absorber with falling film, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 9, pp. 830-838
  255. Yoo, S. Y., Chung, M. H. and Lee, Y. M., 2005, A study on the factors affecting the performance of plastic plate heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp. 839-848
  256. Jang, S. P., 2005, Cooling performance of a microchannel heat sink with nanofluids, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp. 849-854
  257. Noh, J. S., Lee, K. B. and Lee, C. G., 2005, Pressure loss and forced convective heat transfer in an annulus filled with aluminum foam, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp. 855-862
  258. Park, B. Y., Jung, Y. H., Ham, H. D. and Sohn, J. Y., 2005, Evaluation of indoor environment characteristics through field measurement in large-sized discount stores, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp. 863-872
  259. Lee, Y.-J., Jin, W.-F., Yeo, M.-S. and Kim, K.-W., 2005, An experimental study on the application of polypropylene capillary tube cooling system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No.9, pp.873-881
  260. Ha, J.-C., Hwang, J.-H., Baek, I.-C. and Jung, D., 2005, Performance of R502 alternative refrigerants for low temperature applications, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp.883-890
  261. Bai, C. H., Lim, Y. H., Gulnora, D., Park, J. Y., Kwak, K. M., Chu, E. S., Kim, Y. S. and Kim, J. Y., 2005, A study on the characteristics of total heat exchanger under various conditions, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp.891-897
  262. Kim, S. I., Kim, K. M., Lee, D. H., Jeon, Y. H. and Cho, H. H., 2005, Change of heat transfer characteristics in a rotating channel od square duct at wall with bleed holes (I) - Effect of rotation speed, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No. 10, pp.898-906
  263. Kim, S. I., Kim, K. M., Lee, D. H., Jeon, Y. H. and Cho, H. H., 2005, Change of heat transfer characteristics in a rotating channel of square duct at wall with bleed holds (II) - Effects of exit mass flow rate, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp. 907-913
  264. Yang, S. S., Ryou, H. S., Choi, Y. K. and Kim, D. H., 2005, An experimental study on the effect of ventilation velocity on the burning rate in longitudinal ventilation tunnel fires, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp.914-921
  265. Lee, K. H., Cho, S. W., Choi, J. M., Kim, K. H. and Park, C. S., 2005, The study on the improvement of ventilation performance in the soundproof tunnel, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp.922-929
  266. Kim, Y., Lee, H. and Lim, Y., 200S, Heat transfer characteristics of flat plate finned-tube heat exchangers with a variation of fin pitch and number of tube row, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp.930-937
  267. Lee, S., Lee, J. and Park, K., 2005, An application of multi-objective global optimization technique for internally finned tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10, pp. 938-946
  268. Ham, H. D., Park, B. Y. and Sohn, J. Y., 2005, Evaluation of thermal performance for air-barrier air-conditioning system in perimeter zone by scale model experiment and simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 10. pp.947-955
  269. Chung, M. H. and Yoo, S. Y., 2005, A study on the factors affecting the performance of paper heat exchanger for exhaust heat recovery, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No. 10, pp. 956-964
  270. Yang, D. K. and Lee, K. S., 2005, Analysis of frosting performance of a fin-tube heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp. 965-973
  271. Yang, D. K. and Lee, K. S., 2005, Optimization of frosting performance of a fin-tube heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.974-980
  272. Yoo, G.-S., Hwang, J.-W., Park, K.-J. and Jung, D., 2005, External condensation heat transfer coefficients of R22 alternative refrigerants and R134a according to the saturation vapor temperature change on an enhanced tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No. 11, pp.981-989
  273. Lee, Y. S., Lee, S. N. and Kim, J. R., 2005, Effect on stratification due to diffuser shape in a thermal storage tank, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.990-997
  274. Yee, J. J., Ihm, P. C. and Kim, H. Y., 2005, Sensitivity analysis on KS and JIS standard for heat recovery ventilator, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.998-1004
  275. Park, C. S., Kim, B. H., Kim, Y. C., Lee, Y. S. and Bang, K. Y., 2005, Simulation on the heating performance of a 2-stage compression heat pump system using river water, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 1005-1013
  276. Park, B. K. and Lee, J. S., 2005, Analysis of geometrical effects on heat transfer characteristics in a modular flat tube-bundle heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.1014-1021
  277. Lee, J. I., Hwang, Y. J., Joo, H. Y., Ahn, Y. C., Shin, H. S. and Lee, J. K., 2005, Characteristic of the ion wind using corona discharge and enhancement of heat transfer, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.1022-1027
  278. Oh, M. K., Kim, H. J., Kim, S. S. and Kang, Y. T., 2005, Simulation and experimental study on an air-cooled $NH_3/H_2O$ absorption chiller, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp. 1028-1034
  279. Kim, B. J., 2005, Flow characteristics of a laminar rivulet down an inclined surface, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp. 1035-1042
  280. Choi, J. Y., Yu, J. S, and Jeong, Y. I., 2005, A study on the calculation of ventilation rate for the improvement of indoor air quality on the barracks, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp. 1043-1049
  281. Yoo, S. Y., Shim, W. S. and Kim, S. C., 2005, A study on the pollutant dispersion over a mountain valley region (I): Wind tunnel experiments, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp. 1050-1059
  282. Shim, W. S., Kim, S. C. and Yoo, S. Y., 2005, A study on the pollutant dispersion over a mountain valley region (II): Numerical simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp. 1060-1071
  283. Shin, Y. G., Yang, H. C., Tae, C. S., Jang, C. Y., Cho, S. and Kim, Y. I., 2005, A study on Pill tuning technique of a thermal environment chamber, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.1072-1078
  284. Han, C. W., Noh, K. C. and Oh, M. D., 2005, Evaluation of thermal comfort and ventilation performance in the lecture room with ventilation system and two different air-conditioning systems: system air-conditioner or fan coil unit, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.1079-1087
  285. Peck, J. H., Chung, D. Y., Kang, C. and Hong, H., 2005, Measurement of the ice packing factor of an aqueous solution using the index of refraction, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 11, pp.1088-1094
  286. Lee, S. H., 2005, A study on the transient convective heat transfer for supercritical water in a vertical tube, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1095-1105
  287. Choi, J. M. and Kim, Y., 2005, Performance of short tube orifices using R-410A near the critical region, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1106-1112
  288. Hwang, Y. W., Kim, J. H. and Kim, M. S., 2005, A study on the evaporative heat transfer in microtubes, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp. 1113-1122
  289. Kim, J. H., Kang, D. H., Choi, D. H., Kim, S. S., Yeo, M. S. and Kim, K. W., 2005, A study on the numerical analysis of VOCs emission from plywood floor material, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp. 1123-1131
  290. Lee, J.-I., Kim, Y.-H., Park, C.-S. and Ha, O.-K., 2005, The study on the performance characteristics due to the degree of superheat in $NH_3$ refrigeration system (III) - The comparison of heat exchanger types, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1132-1138
  291. Suh, J. S., Park, Y. S. and Chung, K. T., 2005, Analysis of thermal control characteristics of VCHP by the charging mass of non-condensible gas, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1139-1145
  292. Hwang, T.-G., Doh, D.-H., Park, S.-R., Bang, Y.-S., Yang, M.-C., Jang, G.-S., Kim, S.-R. and Lee, Y.-W., 2005, Power saving of a refrigerator with 3D-PTV measurements, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp. 1145-1153
  293. Hwang, T. G. and Doh, D. H., 2005, Analysis of airflows in a room with panoramic PIV, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp. 1154-1160
  294. Hwang, T. G. and Doh, D. H., 2005, Development of high-definition 3D-PIV and its application to high-precision measurements of a sphere wake, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp. 1161-1168
  295. Lee, T. G., Moon, J. S., Yoo, H. and Lee, J. H., 2005, Thermal reliability analysis of BLDC motor in a high speed axial fan by the accelerated life test, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1169-1176
  296. Park, B. K. and Lee, J. S., 2005, Numerical analysis on the condensation heat transfer and pressure drop characteristics of the flat tube-bundle heat exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1177-1184
  297. Lee, K. Y. and Park, K. K., 2005, A proposal of a correlation of the enthalphy of vaporization for pure substances and performance comparison of correlations, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 12, pp.1185-1191
  298. Choi, J. M., Sim, Y. H., Lee, S. H., Lee, J. H., Lee, J. W., Park, S. R., Kim, Y. C. and Yoon, J. S., 2005, An analysis of the control and defrost patents for heat pump, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, pp. 1192-1203
  299. Shin, Y. G., Yang, H. C., Tae, C. S., Cho, T. S. and Kim, Y. G., 2005, In-situ measurement of chiller performance and thermal storage density of an ice thermal storage system, Korean Journal of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 17, No. 12, pp.1204-1209