주거건물의 개별급탕방식 환탕배관 적용에 따른 급탕성능 평가에 관한 연구

A Study on the Performance Evaluation of Recirculation System for Individual Hot Water Supply System in Residential Buildings

  • 차민철 (영남대학교 건축공학과 대학원) ;
  • 여명석 (서울대학교 건축학과) ;
  • 석호태 (영남대학교 건축학부)
  • Cha, Min-Chul (Department of Architectural Engineering, Graduate School, Yeungnam University) ;
  • Yeo, Myoung-Souk (Department of Architecture, Seoul National University) ;
  • Seok, Ho-Tae (School of Architecture, Yeungnam University)
  • 발행 : 2007.12.10

초록

In the current residential building, hot water supply system consumes the second largest energy in order to make the thermal comport condition of residential space. The more residential environment improves the more the demand for hot water and water consumption is increasing gradually. So this study examines the possibility of applying the recirculation for individual hot water supply system compared with the existing method for waiting time for hot water, wasted water and energy consumption. The results are as follows. (1) In case of recirculation system method the waiting time for hot water can be reduced up to $69\sim85%$ in spring and fall period and so dose up to $77\sim85%$ in winter period. (2) The total wasted water has a little change compared with the existing method which can make the total wasted water reduced about $77\sim86%$. (3) The efficiency of hot water supply system can be improved, if the method which blocks the inflow of cold water is applied, when return pump is operated to recirculate hot water in recirculation system.

키워드

참고문헌

  1. Choi, C. H. and Suh. S. J., 2000, An experimental study on the efficiency evaluation of hot water supply system, Journal of the AIK, Vol. 16, No.9, pp. 169-177
  2. Baskin, E. Wendt, R, Lenarduzzi, R, Woodbury, K. A., 2004, Numerical evaluation of alternative residential hot water distribution systems, ASHRAE Transactions, Vol.110 No.2, pp. 671-681
  3. Hiller, C. C., 2006, Hot water distribution system piping time, water, and energy wastephase 1 : test results, ASHRAE Transactions, Vol. 112, No.1, pp.415-425
  4. Klein, G., 2005, National impact of hot water distribution system losses in residences, ASHRAE Transactions, Vol. 111, No.2, pp. 423-429
  5. Lutz, J. D., 2005, Estimating energy and water losses in residential hot water distribution systems, ASHRAE Transactions, Vol. 111, No.2, pp.418-422
  6. ASHRAE, 1996, Basic water system design, ASHRAE Handbook, U.S.A
  7. Erwin, G. H., 1985, Hydronic System Design and Operation, McGraw-Hill, U.S.A