Abstract
The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.