Visual Performance Evaluation of Daylighting System with Sloped Lightshelves

광선반 채광시스템의 시각적 성능 평가

  • Published : 2006.06.30

Abstract

This study assessed the visual performance of luminous environment by the lightshelf. The subject survey method was used and results are presented and analyzed. The lightshelf daylighting system was developed by LAEL at KH University and was applied on the window of a mock-up office. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. The experiment was conducted during the bright part of the day from noon to one thirty on June 7, 2006. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. During the experiment was carrying out, the work plane illuminance and luminous distribution at surrounding the windows was measured. The semantic differential rating data of experiment were analyzed by t-test and factor analysis using SPSS 12.0 statistics package. The visual performance of the lightshelf was more positive. The factors affecting the visual performance are task performance and visual comfort. The subjects were more comfortable in a room installed with lightshelves on both the task performance and the visual comfort aspect. Therefore, the application of sloped lightshelf daylighting system improves visual performance of luminous environment.

Keywords

References

  1. Marie-Claude Dubois, Impact of Shading Devices on Daylight Quality in offices. Lund University, 2001
  2. Staffan Hygge, User Evaluation of Visual Comfort in Some Buildings of the Daylight europe Project, 1997
  3. IEA SHC Task 31,www.iea-shc.org/task31
  4. Helena Bulow-Hube et al 1, 'Subjective reactions to daylight in rooms: Effect of using low-emittance coatings on windows', Lighting Research and Technology 27(1) pp.37-44 1995 https://doi.org/10.1177/14771535950270010601
  5. Toshie Iwata et al 1, 'Survey on workers' response to automated blind and lighting control systems in an office', IEA Task 31 and CIE Division 3 mini-conference, 2002
  6. Toshie Iwata et al 4, 'Experimental Study on the integrated lighting system with daylight and artificial light based on the subjective response and energy saving', IAEEL(International Association for Energy-Efficient lighting) Right light 4 vol.2 pp.255-259, 1997년
  7. Soo-Young Kim, 'Analysis of fluctuation light on visual comfort for the applications of daylighting dimming control system', Doctoral Dissertation, University of Mischgan, 2005
  8. ETAP Lighting et al 2, 'The ETAP daylight system user acceptance study'
  9. Anna Pellegrino, 'Indoor environmental conditions and users responses in offices', IEA SHC Task 31 & CIE Division 3, Mini-conference, Ottawa, 2002년 10월
  10. The University of California IEQ(Occupant Indoor Environmental Quality) Survey, Lighting, (revised Jan. 13, 2005)
  11. 김병수 외 2, '시각적 쾌적성과 에너지 성능분석에 의한 오피스 창호의 적정 투과율 선정', 대한건축학회 논문집 21권 3호, pp.107-115 2005년
  12. 정인영, '복합투과방식을 적용한 실내환경의 채광성능평가', 경희대학교 박사학위논문, 2004
  13. 이진숙 외 1, '창면 불쾌글레어 평가실험에 적용된 실험변수의 민감도 분석에 관한 연구', 대한건축학회 논문집 20권 5호 2004년 5월, pp.193-200
  14. 이영욱, '아트리움의 자연채광 성능평가에 관한 연구', 경희대학교 박사학위 논문, 1997년
  15. 정유근 외 2, '유리색에 따른 아트리움 실내공간의 채광 분위기 평가', 한국생태환경건축학회 논문집 제3권 3호 pp.51-58, 2003년 9월
  16. 하미경 외 3, '대학 강의실 환경개선 후 평가(POE) 연구', 대한건축학회 논문집 20권 10호 pp.23-31
  17. 신현구, '광선반의 채광성능평가에 관한 연구', 경희대학교 석사학위논문, 2003
  18. 유우상 외 1, '사무공간 레이아웃에 따른 근무자의 시각적 교류에 관한 연구', 한국실내디자인학회논문집 제 14권 5호, pp.37-43, 2005년 10월
  19. www.kma.go.kr
  20. www.learn.londonmet.ac.uk