Abstract
In this paper, procedures and research results involved in the development of glass reinforced composite bridge deck of hollow section were presented. Laminate design for the 3 cell deck section was performed. Structural characteristics such as serviceability, strength, failure and stability for DB24 load were analytically studied through the finite element analysis for the composite deck plate girder bridge. Composite deck tube was fabricated with pultrusion and extensive tests such as flexural test, girder-connection test, barrier-connection test, compression fatigue test and flexural fatigue test were carried out to evaluate structural behavior experimentally. Also, field load test was conducted for the demonstration plate girder bridge with composite deck and requirements for the strength and serviceability were reviewed.
본 논문에서는 중공단면 형상의 유리섬유 강화 복합소재 교량바닥판의 개발에 관련된 연구 절차와 결과를 기술하였다. 설계된 3셀 단면에 대해 적층설계를 수행하였고, DB24 하중에 대한 플레이트 거더 복합소재 바닥판 교량의 유한요소해석을 통하여 처짐 사용성, 강도, 파괴 및 좌굴안정성 등의 구조적 특성을 평가하였다. 설계, 해석된 복합소재 바닥판 튜브는 인발성형으로 제작하였고, 구조적인 거동을 실험적으로 평가하기 위해 3점 휨시험, 거더 연결부시험, 방호벽 연결부시험을 실시하였고, DB24하중의 200만회 반복하중에 대해 압축피로시험, 휨피로시험 등 광범위한 구조성능시험을 실시하였다. 또한 시범시공된 복합소재 바닥판 플레이트 거더교량에 대한 현장 재하시험에서도 구조 안전성 및 사용성을 검토 하였다.