References
- Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983:50:399-410 https://doi.org/10.1016/S0022-3913(83)80101-2
- Lee CW. The Comparison of Internalvs-External Implant/Abutment connection. Dental Implants JungWonSa 2002:66-77
- Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent 1999 May:81 (5): 537-52 https://doi.org/10.1016/S0022-3913(99)70208-8
- Tolman DE, Laney WR. Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 1992 Winter:7(4): 477-84
- Carlson B, Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. Int J Oral Maxillofac Implants 1994 Jan-Feb:9(1) :90-4
- Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998 Jan:79(1) :74-8 https://doi.org/10.1016/S0022-3913(98)70197-0
- Binon PP. The external hexagonal interface and screw-joint stability: A primer on threaded fasteners in implant dentistry. QDT 2000:23:91-104
- McGlumphy EA Mendel DA Holloway JA Implant screw mechanics. Dent Clin North Am 1998 Jan:42(1):71-89
- Binon PP, Sutter F, Beaty K. Brunski J, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994; 9: 48-63
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001 Jul: 86(1) :24-32 https://doi.org/10.1067/mpr.2001.116230
- Lang LA May KB, Wang RF. The effect of the use of a counter torque device on the abutment-implant complex. J Prosthet Dent 1999 Apr:81(4) :411-7 https://doi.org/10.1016/S0022-3913(99)80007-9
- Korioth TW, Cardoso AC, Versluis A. Effect of washers on reverse torque displacement of dental implant gold retaining screws. J Prosthet Dent 1999 Sep: 82(3):312-6 https://doi.org/10.1016/S0022-3913(99)70086-7
- Bickford JH. An introduction to the design and behavior of bolted joints. New York: Marcel Dekker: 1981. p.247-64.9
- Cibirka RM, Nelson SK. Lang BR, Rueggeberg FA. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001 Mar:85(3): 268-75 https://doi.org/10.1067/mpr.2001.114266
- Haack JE. Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofacial Implants 1995: 10: 529-36
- Gratton DG, Aquilino SA Stanford CM. Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent 2001 Jan:85(1) :47-52 https://doi.org/10.1067/mpr.2001.112796
- Sakaggchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screw. Int J Oral Maxillofacia Implants 10: 295-302, 1995
- Lee DH et al. Osseointegrated Implant. Shinhung International p479
- Jorneus L, Jemt T, Carlsson L. Loads and design of screw for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992:353-359
- Haak JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995: 10: 529-536
- Binon P Weir D. Watanabe L, Walker L. Implant component compatibility. In Laney WR, Tolman, TE (eds) (Proceeding of the 2nd international congress on tissue integration in oral,orthopedic and maxillofacial reconstruction23-27 Sep .1990, Mayo medial center, Rochester. Minnesota.l Chicago, Quitessence, 1992
- Carr AB, Brunski JB, Hurley E. The effect of finishing and polishing techniques on implant cylinder preload
- Norton MR, An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997 Aug;8(4) :290-8 https://doi.org/10.1034/j.1600-0501.1997.080407.x
- Merz BR. Mechanics of the ImplantAbutment Connection:An 8 Degree Taper Compared to a Butt Joint Connection. Int J Oral Maxillofac Implants 2000; 15 :519-526
- Sutter F, Weber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Periodont Rest Dent 1993; 13: 409-31
- Binon PP. Implants and components: entering the new millennium. Int J Oral Maxillofac Implants 2000 Jan-Feb;15(1): 76-94
- Carlsson GE, Haraldson T. Funtional response in tissue integrated prosthesis, 4th edition. Quintenssence Publ, co. 1986:74-78
- Richter EJ. Related Articles, In vivo vertical forces on implants. Int J Oral Maxillofac Implants. 1995 Jan-Feb; 10(1): 99-108
- Bates JF, Stafford GD, Harrison A. Masticatory funtion-a review of the literature. III. Masticatory perfomance and efficiency. J Oral Rehabilitation 1976:3:57-62 https://doi.org/10.1111/j.1365-2842.1976.tb00929.x
- Graf H. Dent Clin North Am 13:659-665, 1969
- Goheen KL. Vermilyea SG, Vassoughi J. Agar JR, Torque generated by hand held screw drivers and mechanical torquing devices for osseointegrated implants. Int J Oral maxillofac Implants 1994: 149-155
- Lee CW. Monthly publication. Dental Clinic. Abutment selection guide. 2001:21(3)
- Jung WH, Kay KS. A study on the use of sealer on implnat abutment loosening. 1996
- Lee JH. Kay KS. An experimental study on single-tooth implant abutment screw loosening to the pitch of thread. 1996
- Kim JM, Han JS. A Study Of Screw Loosening After Dynamic Continuous Fatigue Test Of Several Abutment Screw. The Korean Academy of Prosthodontics 2003 41(4) : 519-531
- Yang JS. Vang MS. A vitro study of retained screw stability by various connection designs between fixture and abutment in implant dentistry. 2003
- English CE. Implant-supported versus implant-natural tooth supported fixed partial denture. Dental Symposia 1993: 1: 10-15