References
- 인천광역시 도시철도건설본부, '인천도시철도 1호선 송도 연장건설사업 기본설계 보고서(토목/궤도)' 2004
- Kevin McGrattan, Glenn Forney, 'Fire Dynamics Simulator(Version 4) User's Guide' NIST, 2005
- T. G. Ma, J. G. Quintiere, 'Numerical simulation of axisymmetric fire plumes: accuracy and limitations' Fire Safety Journal 38, pp. 467-492, 2003 https://doi.org/10.1016/S0379-7112(02)00082-6
- Baum, H. R., B. J. MaCaffery, 'Fire Insuced Flow Field-Theory and Experiment' Fire Safety Science Proceedings of the Second International Symposium, pp. 129-148, 1989
- James A. Milke, 'NFPA 92B, Guide For Smoke Management Systems in Malls, Atria, and Large Areas, 2000 Edition' NFPA, pp. 47-48, 2000
- W. K. Chow, W. Y. Hung, Y. Gao, G. Zou, H. Dong, 'Experimental stusy on smoke movement leading to glass damages in double-skinned facade' Construction and Building Materials, 2005
- William D. Kennedy, 'NFPA 130, Standard for Fixed Guideway Transit and Passenger Rail Systems, 2003 Edition' NFPA, 2003
- G. W. Mulholland, 'The SFPE handbook of Fire Protection Engineering, chapter Smoke Production and Properties' Third Edition, National Fire Protection Association, pp. 2-265-266. 2002
- John H. Klote, James A. Milke, 'Principles of Smoke Management' ASHRAE, SFPE, 2002
- David A. Purser, 'The SFPE handbook of Fire Protection Engineering, chapter Toxicity Assessment of Combustion Products' Third Edition, National Fire Protection Association, pp. 2-83-171, 2002
- Dong-ho Rie, Myung-Whan Hwang, Seong-JungKim, Sung-Wook Yoon, Jae-Woong Ko, Ha-Young Kim, 'A Study of optimal vent mode for the smoke conrtrol of subway station fire' Tunnelling and Underground Space Technology, Vol. 21/3-4 pp. 302- 303, 2006 https://doi.org/10.1016/j.tust.2005.12.158