An Experimental Study on Connection Strength between Tie-bar and Facing block composing Reinforced Earth

보강토옹벽을 구성하는 타이바와 전면블록의 연결강도에 관한 실험연구

  • 이승현 (선문대학교 토목공학과) ;
  • 김병일 (명지대학교 토목환경공학과)
  • Published : 2006.03.01

Abstract

In this paper, connection strength between facing block and tie-bar was investigated through experimental study with varying in-fill material such as concrete, soil and crushed stone. Also, connection strength between anchor block and tie-bar was investigated with varying in-fill material. According to the experimental results, in case of using in-fill concrete, connection strength between facing block and tie-bar was larger than allowable tension load of tie-bar. Whereas in case of using in-fill soil or crushed stone, connection strength between facing block and tie-bar was less or similiar to allowable tension load of tie-bar. Connection strength between anchor block and tie-bar for which crushed stone was used as in-fill material, was larger than allowable tension load of tie-bar.

본 논문에서는 생태축조블록(전면블록)과 타이바로 사용되는 이형철근 그리고 앵커블록과 이형철근 사이의 연결강도를 속채움재료를 콘크리트, 흙, 쇄석으로 달리하여 실험을 통해 구하였다. 실험결과에 따르면 생태축조블록과 이형철근의 연결에 있어서는 속채움 재료로 콘크리트를 사용한 경우 연결강도가 타이바의 허용인장력보다 큰 반면 속채움 재료로 흙 또는 쇄석을 사용한 경우에는 연결강도가 타이바의 허용인장력과 비슷하거나 작게 측정되었다. 앵커블록과 타이바의 연결에 있어서는 속채움 재료로 쇄석을 사용하였는데 연결강도는 타이바의 허용인장력보다 크게 측정되었다.