Failure Analysis of Metallic Components

금속소재 부품의 고장분석 사례

  • 송진화 (포항산업과학연구원 신뢰성평가센터 신뢰성평가실) ;
  • 홍기정 (포항산업과학연구원 신뢰성평가센터 특성분석실) ;
  • 장창환 (포항산업과학연구원 신뢰성평가센터 특성분석실) ;
  • 김영섭 (포항산업과학연구원 신뢰성평가센터 신뢰성평가실)
  • Published : 2006.03.01

Abstract

Failure analyses were conducted on a crank shaft and a chock liner by using X-ray diffraction, optical microscopy and SEM/EDS techniques. In the crank shaft, a crack developed where a maximum tensile stress coincided with band structure formed by hot forging. The maximum tensile stress was observed to originate from volume expansion during high frequency induction heat treatment and the band structure to develop between upper and lower dies during hot forging. In the chock liner, the wear mechanism varied with the chemical affinity and hardness of liner material relative to friction pair of housing liner. Brass of low chemical affinity and hardness compared to housing liner showed uniform adhesive wear. STS 304 and STS 420J2 of high chemical affinity showed galling and scoring respectively.

Keywords