In the air-conditioner, refrigerant induced noise and vibration can be increased when the airflow rate is reduced in order to decrease the noise at the low mode. Through the test and analysis of this kind of noise, it can be verified that the main reasons of refrigerant induced noise are the velocity and flow Induced force of the refrigerant at the inlet of the evaporator, So, in order to reduce this velocity, quality at the evaporator inlet should be minimized. And, in order to reduce flow induced force of the refrigerant, sudden change of fluid flow must not be occurred. So, in this paper, we will review the characteristics of refrigerant cycle and find how the quality and flow induced force can be minimized.

키워드

참고문헌

  1. Whalley, P.B., 1999, 'Two Phase Flow and Heat Transfer', Oxford University Press
  2. Willam, S. J., 1993, 'Design of Fluid Thermal Systems', PWS-Kent Publishing Company
  3. Arora, C. P., 2000, 'Refrigeration and Air Conditioning', McGraw-Hill
  4. Yamamoto, 1998, 'Study of Noise Reduction of Refrigerant for Capillary Tube in the Refrigerator', Mitsubishi, 32th Conference Journal of Refrigeration and Air-conditioning Association, Vol.4, pp. 22-24
  5. Seo, Y.-S. and Jeong, W.-B., 2003, 'Finite Element Vibration Analysis of Cylindrical Shells with Internal Fluid Flow', 2003 Spring Conference Proceedings of the Korean Society for Noise and Vibration Engineering, pp. 911-916
  6. Jang, H. K., Kim, S. H., Rhee, J. H. and Yang, J. R, 1999, 'Reduction of Flow-induced Vibration in the Heat Exchanger', Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 9, No. 6, pp. 1200-1209

피인용 문헌

  1. Study of the Assembly of Indoor Air-conditioner Unit Using Tolerance Analysis vol.39, pp.4, 2015, https://doi.org/10.3795/KSME-A.2015.39.4.423
  2. Experimental study of the effects of the cycle characteristics on the refrigerant-induced noise in system air-conditioner vol.21, pp.7, 2007, https://doi.org/10.1007/BF03027661
  3. Experimental analysis for reducing refrigerant-induced noise of 4-way cassette type air conditioner vol.23, pp.5, 2009, https://doi.org/10.1007/s12206-008-1128-8