The Stability of Strip Footing above Underground Cavity

지하공동에 인접한 연속기초의 안정성

  • 오세욱 (영재이엔씨(주) 기술연구소) ;
  • 이봉직 (충주대학교 토목공학부) ;
  • 배우석 (청주대학교 토목환경공학과)
  • Received : 2006.03.07
  • Accepted : 2006.05.11
  • Published : 2006.06.01

Abstract

In this study, an experimental study in sand ground that was prepared by raining method was performed for modeling the bearing capacity behavior of strip footing above a cavity. The critical range of bearing capacity of the strip footing affected by underground cavity was investigated by comparing results between experiment and theory. The size of the critical region depends on several factors such as footing shape, soil property, cavity size and cavity shape. The ultimate bearing capacity was more influenced by the depth of the underground cavity than the eccentricity of the underground. In addition, an underground cavity influences on not only the decrease of the bearing capacity, but also the differential settlement of a strip footing.

본 연구는 모래지반에서 공동위에 위치한 연속기초의 지지력거동을 연구하기 위하여 강사법으로 조성된 모래지반에서 모형실험을 수행하였다. 모형실험결과와 이론식을 비교하여 지하공동이 연속기초의 지지력에 영향을 미치는 한계범위를 도출하였다. 한계범위의 크기는 기초의 형상, 지반특성, 공동크기, 공동형상 등 여러 가지 인자에 의존한다. 지하공동의 깊이가 편심거리보다 극한지지력에 더 큰 영향을 주는 것으로 나타났다. 또한 연속기초에 미치는 지하공동의 영향은 편심거리에 따른 지지력 감소현상 뿐만 아니라 연속기초의 부등침하 현상에도 큰 영향을 줄 것으로 판단되었다.

Keywords