Abstract

This study carried out an evaluation of an oil tank that was defective in structure. This paper is divided into two sections which are analysis for the working process and suggestion for improving on the structure of the oil tank. As stated above, it has three major factors as to an improvement, such as the life cycle of structure (especially physical life cycle), and the many factors related to the duration years of the oil tank and analysis result. Based on this study, the improvement of oil tank was established. For example, the ground investigation needs before design and construction of oil tank, and constructing the oil tank by retaining wall type tank is good for maintenance. Also, it is important that the system for drainage is related to maintenance.

유류탱크 구조물을 대상으로 기 실시한 유류탱크 정밀안전진단 결과를 중심으로 구조적 문제점을 도출하고 이를 근간으로 내구년수를 결정하는 기법에 대하여 제시하고자 하였으며 추가로 구조적 개선사항도 제안하였다. 정밀안전진단 결과 폐기된 유류탱크를 분석하면 시공년도와는 상관없이 시공, 유지관리 등의 정도에 따라 상이한 것으로 분석되며, 탱크형식별로는 매립형의 건전성이 가장 취약한 상태이다. 또한 손상원인별로 분석한 결과 강재 부분에 대해서는 강재의 두께, 용접 불량이 가장 많은 상태이며, 기초의 영향에 따른 부등침하의 원인도 다수 조사되었다. 또한, 유류탱크의 수명은 일반적으로 30년 정도를 예상수명으로 관리하고 있으며 연구 결과 내구년수는 30년으로 추정 할 수 있었다.

Keywords

References

  1. 시설물의 안전관리에 관한 특별법, 1999.
  2. 시설안전기술공단, 안전점검 및 정밀안전진단 세부지침, 1996.
  3. 시설안전기술공단 , 안전점검 및 정밀안전진단 실무요령, 1997.
  4. 건설교통부, 방식기술편람, 1998.
  5. 건설부, 시설물 유지관리지침, 1987.
  6. 한국건설방식기술연구소, 부식과 방식기술, 1993
  7. ASTM (American Society for Testing and Material)
  8. John A. Franklin,Mcgraw-Hill, Rock Engineering Applications, 1991.
  9. B.H.G Brady & E.T., RockMechanics for underground mining chakpman & Hall
  10. Geotechnical Engineering Office Civil Engineering Department Hong Kong, Guide to Rock and soil Descriptions, 1989.
  11. Welded Steel Tanks for Oil Storage, API STANDARD 650.