Effects of heat treatment on the load-deflection properties of nickel-titanium wire

니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화

  • Chang, Soo-Ho (Department of Orthodontics, School of Dentistry, Chosun University) ;
  • Kim, Kwang-Won (Department of Orthodontics, School of Dentistry, Chosun University) ;
  • Lim, Sung-Hoon (Department of Orthodontics, School of Dentistry, Chosun University)
  • 장수호 (조선대학교 치과대학 교정학교실) ;
  • 김광원 (조선대학교 치과대학 교정학교실) ;
  • 임성훈 (조선대학교 치과대학 교정학교실)
  • Published : 2006.10.30

Abstract

Objective: Nickel-titanium alloy wire possesses excellent spring-back properties, shape memory and super-elasticity. In order to adapt this wire to clinical use, it is necessary to bend as well as to control its super-elastic force. The purpose of this study is to evaluate the effects of heat treatment on the load-deflection properties and transitional temperature range (TTR) of nickel-titanium wires. Methods: Nickel-titanium wires of different diameters ($0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ and $0.0215"\;{\times}\;0.028"$) were used. The samples were divided into 4 groups as follows: group 4, posterior segment of archwire (24 mm) without heat treatment; group 2, posterior segment of archwire (24 mm) with heat treatment only; group 3, anterior segment with bending and heat treatment; group 4, anterior segment with bending and 1 sec over heat treatment. Three point bending test was used to evaluate the change in load-deflection curve and obtained DSC (different scanning calorimetry) to check changes in $A_f$ temperature. Results: In the three point bending test, nickel-titanium wires with heat treatment only had higher load-deflection curve and loading and unloading plateau than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment had lower Af temperature than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment and bending had higher load-deflection curve than nickel- titanium wires with heat treatment and nickel-titanium wires without heat treatment. Nickel-titanium with heat treatment of over 1 sec and bending had the highest load-deflection curve. Nickel-titanium wires with heat treatment and bending had lower Af temperature, Nickel-titanium wires with heat treatment of over Af sec and bending had the lowest Af temperature. Conclusion: From the results of this study, it can be stated that heat treatment for bending of Nickel-titanium wires does not deprive the superelastic property but can cause increased force magnitude due to a higher load-deflection curve.

니켈-티타늄 합금은 높은 spring-back성질, 초탄성 효과, 형상기억 효과 등의 장점을 가지고 있으나 성형이 어렵다는 단점을 가지고 있다. 본 연구에서는 니켈-티타늄 와이어의 굴곡을 위한 열처리 시에 나타나는 부하-변위 곡선의 변화 및 상전이 온도 변화와 같은 물성 변화 양상을 조사하고자 하였다. 수종의 니켈-티타늄 와이어를 열처리를 시행하지 않은 군, 전기저항 열처리 장치를 이용하여 와이어 단면적에 따라 제조회사에서 권장하는 전류를 기초로 하여 $00.016"\;{\times}\;00.022"$ (5 A, 7 sec), $0.018"\;{\times}\;0.025"$ (6 A, 7 sec) 그리고 $0.0215"\;{\times}\;0.028"$ (7 A, 8 sec) 와이어를 열처리만 시행한 실험군, 열처리를 시행하여 굴곡을 부여한 실험군 그리고 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군으로 분류하여 3점 굴곡 실험과 시차주사열량측정을 하여 다음과 같은 결과를 얻었다. $0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 니켈-티타늄 와이어에서 굴곡을 부여하지 않고 열처리만 시행한 실험군이 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되어 초탄성 현상에 의한 평탄역(loading and unloading plateau)의 힘이 더 증가되었다. $0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 열처리만 시행한 실험군이 열처리를 시행하지 않은 군보다 더 낮은 austenite finish ($A_f$) 온도를 보였다. $0.018"\;{\times}\;0.025"$$0.0215"0.028"$ 와이어에서 열처리를 시행하여 굴곡을 부여한 실험군은 열처리만 시행한 실험군과 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되었으며, 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 높은 부하-변위 곡선을 나타냈다. $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 $A_f$ 온도는 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 낮게 관찰되었고 열처리를 시행하여 굴곡을 부여한 실험군, 열처리만 시행한 실험군 그리고 열처리를 시행하지 않은 대조군 순으로 높게 관찰되었다. 이상의 결과를 종합할 때, 임상에서 니켈-티타늄 합금 와이어에 굴곡을 부여하기 위해 열처리하는 경우 초탄성 특성은 유지될 수 있으나, 부하-변위 곡선의 상방 증가가 나타나므로, 와이어에 의한 교정력이 증가될 수 있음에 유의하여야 한다.

Keywords

References

  1. Kim YB. A reassessment of orthodontic wire selection. J Korean Gnatho-Orthod Res 1995;2:151-97
  2. William AB, Theodore E. Wire Alloy. Orthodontic materials scientific and clinical aspects 2001;4:84-104
  3. BK Cha, DS Choi, NK Lee. SimpIication of orthodontic treatment procedure using superelastic Ni-Ti archwires: One wire system. Korean J Clin Orthod 2005;11:82-9
  4. Miyazaki S, Ohmi Y, Otsuka Y, Suzuki Y. Characteristics of deformation and transformation pseudoelasticity in Ti-Ni alloys. J Phys-Paris supplement 1982;255-60
  5. Miura F, Mogi M, Ohura Y. Japanese NiTi alloy wire: use of the direct electric resistance heat treatment method. Eur J Orthod 1988;10:187-91 https://doi.org/10.1093/ejo/10.1.187
  6. American Dental Association ASC MD 156: Restorative and Orthodontic Materials. Specification #32
  7. Andreasen GF, Hilleman TB. An evaluation of 55 cobalt substituted Nitinol wire for use in orthodontics. J Am Dent Assoc 1971;82:1373-5 https://doi.org/10.14219/jada.archive.1971.0209
  8. Andreasen GF, Brady PR. A use hypothesis for 55 Nitinol wire for orthodontics. Angle Orthod 1972;42:172-7
  9. Andreasen GF, Morrow RE. Laboratory and clinical analyses of nitinol wire. Am J Orthod 1978;73:142-51 https://doi.org/10.1016/0002-9416(78)90184-7
  10. Burstone CJ, Qin B, Morton JY. Chinese NiTi wire-a new orthodontic alloy. Am J Orthod 1985;87:445-52 https://doi.org/10.1016/0002-9416(85)90083-1
  11. Miura F, Mogi M, Ohura Y, Hamanaka H. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics. Am J Orthod Dentofacial Orthop 1986;90:1-10 https://doi.org/10.1016/0889-5406(86)90021-1
  12. Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of supere1astic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop 2002;121:483-95 https://doi.org/10.1067/mod.2002.121819
  13. Nakano H, Satoh K, Norris R, Jin T, Karnegai T, Ishikawa F, Katsura H. Mechanical properties of several nickel-titanium alloy wires in three-point bending tests. Am J Orthod Dentofacia1 Orthop 1999;115: 390-5 https://doi.org/10.1016/S0889-5406(99)70257-X
  14. Oltjen JM, Duncanson MG Jr, Ghosh J, Nanda RS, Currier GF. Stiffuess-deflection behavior of selected orthodontic wires. Angle Orthod 1997;67:209-18
  15. Stamm T, Hohoff A, Wiechmann D, Sutfeld J, Helm D. Accuracy of third-order bends of nickel-titanium wires and the effect of high and low pressure during memorizing heat treatment. Am J Orthod Dentofacial Orthop 2004;126:476-85 https://doi.org/10.1016/j.ajodo.2003.07.011
  16. Otsubo K, Yoneyama T, Hamanaka H, Soma K. Influence of temperature on the force level of a super-elastic Ni-Ti alloy wire under strain. J J Dent Mater 1993;12:521-7
  17. Kusy RP. A review of contemporary archwires: their properties and characteristics. Angle Orthod 1997;67:197-207
  18. Chen R, Zhi YF, Arvystas MG. Advanced Chinese NiTi alloy wire and clinical observations. Angle Orthod 1992;62:59-66
  19. Bradley TG, Brantley WA, Culbertson BM. Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel -titanium orthodontic wires. Am J Orthod Dentofacial Orthop 1996;109:589-97 https://doi.org/10.1016/S0889-5406(96)70070-7
  20. Abel E, Luo H, Pridham M, Slade A. Issues concerning the measurement of transformation temperatures of NiTi alloys. Smart Mater Struct 2004;13:1110-7 https://doi.org/10.1088/0964-1726/13/5/016
  21. Gamer LD, Allai WW, Moore BK. A comparison of frictional forces during simulated canine retraction of a continuous edgewise arch wire. Am J Orthod Dentofacial Orthop 1986;90:199-203 https://doi.org/10.1016/0889-5406(86)90066-1
  22. Yoneyama T, Doi H, Hamanaka H, Okamoto Y, Mogi M, Miura F. Super-elasticity and thermal bahavior of Ni-Ti alloy orthdontic arch wires. Dent Mater J 1992;11:1-10 https://doi.org/10.4012/dmj.11.1
  23. Lee JH, Park JB, Andreasen GF, Lakes RS. Thermomechanical study of Ni-Ti alloys. J Biomed Mater Res 1988;22:573-88 https://doi.org/10.1002/jbm.820220611
  24. Gil FJ, Manero JM, Planell JA. Effect of grain size on the martensitiec transformation in NiTi alloy. J Mater Sci 1995;30:2526-30 https://doi.org/10.1007/BF00362129