Comparison of Glass Particle Contamination according to Method of Ampule Cutting and Needle Aspiration

유리앰풀 개봉 관련 요인에 따른 주사용액 내 유리조각 혼입 정도 비교

  • Published : 2006.10.31

Abstract

Purpose: Glass particle contamination of the contents of single-dose glass ampules can occur upon opening. Different aspiration techniques, different sizes of needles, different sizes of ampules, and different cutting methods were studied to determine if they had any effect on glass particle contamination. Method: Different aspiration techniques(with filter, without filter), different sizes of needles(18G, 25G), different sizes of ampules(2ml, 20m1), and different cutting methods(with cotton, without cotton) were evaluated. Method: Twenty ampules were randomly assigned in each group. Three slides containing glass particles for each ampule were made and counted under a microscope by 3 study blind persons. Result: The number of glass particle contamination is much less when using a filter rather than without a filter. The number of glass particle contamination is much less when using a 25G needle rather than on 18G needle. The number of glass particle contamination is much less when using 2ml ampules rather than 20m1 ampules. The number of glass particle contamination is much less when using cotton rather than without cotton. Conclusion: It was shown that using a filter, a small size needle, smaller sized ampules and using cotton when cutting the ampule will decrease the risk of parenteral injection of glass particles.

Keywords

References

  1. Carbone-Traber, K. B., Shank. C. A. (1986). Glass partic.e contamination in single dose ampules. Anesth Analg, 65, 1361-1363
  2. Chae, J. H., Kim, W.O., Kil, H. K., & Kim, J. R. (1990). Glass particle contamination in single dose ampules upon opening. Korean J Anestheisol, 23(5), 668-691
  3. Choi M. H., Park S. H., Choi B. K. Kang Ch. S., Lee S. H., Kim G. S. (2000). Tests for Volume of injectionsn containers. J Korean Pharm Sci, 30(3), 223-228
  4. Falchuk K. H., Peterson L., & McNeil B. J. (1985). Micro-particulate-induced phlebitis: Its prevention by in line filtration. N Engl J Med, 312, 78-82 https://doi.org/10.1056/NEJM198501103120203
  5. Furgang, F. A. (1974). Glass particles in ampules. Anesthesiology, 41(5), 525
  6. Katz, H., Borden, H., &Hirscher, D. (1973). Glass-particle contamination of color-break ampules. Anesthesiology, 39(3), 354 https://doi.org/10.1097/00000542-197309000-00025
  7. Kim, K. S. (1988). Comparison of two intramuscular injection techniques on the severity of discomfort and lesions at the injection site. J Korean Acad Nurs, 18(3), 257-268
  8. Park, K. J. (2002). Issues of injection on children' hospital. J Korean Soc Health-Syst. Pharm, 19(2), 153-156
  9. Pinnock, C. A. (1984). Particulate contamination for intrarthecal use. Ann R Coli Surg Engl, 66, 423
  10. Purdue, H., & Punchihewa, V. G. (1982). Glass fragments in thiopenlone sodium solution. Anaesthesia, 37, 101-102
  11. Reduction of injection prescription. (2004, September 10). Chol News, http://news.chol.com/webnews/module
  12. Sabon, R. L., Cheng, E. Y., Stommel, K. A., & Hennen, C. R. (1989). Glass particle contamination : Influence of aspiration methods and ampule type. Anesthesiology, 70, 859-862 https://doi.org/10.1097/00000542-198905000-00024
  13. Shaw, N. J., & Lyall, E. G. H. (1985). Hazards of glass ampules. Br Med J, 291, 1390 https://doi.org/10.1136/bmj.291.6506.1390
  14. Shim, C. K., Han, Y. H., & Kwon, D. S. (1991). Comparative study of particulate contamination form ampoule and prefilled syringe. J Korean Pharm Sci, 21(3), 155-160
  15. Song, I. J .(2004). Historical perspective and future direction for intravenous injectable drug dispensing in the seoul national university hospital. J Korean Soc Hosp Pharm, 21(2), 1-12
  16. Suk, M. H., Gil, S. Y., & Park, H. J. (2002). The effects of guided imagery on nursing students performing intramuscular injections. J Korean Acad Nurs, 32(6), 784-791 https://doi.org/10.4040/jkan.2002.32.6.784
  17. Sung, G. M. (2003). Differences in perceived and muscle contraction by intramuscular injection methods. Unpublished master's thesis, Konkuk University, Seoul
  18. Waller, D. G., & George, C. F. (1986). Ampules, infusions, and filters. Br Med J, 292, 714-715 https://doi.org/10.1136/bmj.292.6522.714