Design of Double Digital Controller to Improve Performance for the Silent Discharging Ozonizer

무성방전 오조나이저의 성능개선을 위한 2중 디지털 제어기의 설계

  • Published : 2006.03.01

Abstract

In this paper, a control method of ozone generator for a tiny deodorizer is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2[^{\circ}C]$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the respond characteristics with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.

Keywords

References

  1. Tae, H. K. and Joon, W. K., 'A study on the ozone consumption rate for drinking water treatment process with ozone application', Journal of KSEE, VOl. 27, pp. 663-669, 2005
  2. Jae, W. C. and Moo, H. C., 'Ozone generation characteristics of silent discharge process', Journal of KSEE, Vol. 28, pp. 305-312, 2004
  3. Hiroaki, M. Y. and Masahiro, H. N., 'Space charge distribution for various glass materials under DC stress', IEEJ Trans. FM, Vol. 123, No.1, pp. 62-69, 2003 https://doi.org/10.1541/ieejfms.123.62
  4. Song, H. J. and Lee, K. S., 'Trial manufacture and characteristics of a multi-discharge type ozonizer', Trans. KIEE. Vol. 48c, pp. 533-541, 1999
  5. Hun, C. L. and Sung, H. W., 'Trial manufacture of a ozone generator using silent discharge type and improvement Properties of the water quality in the lake', Trans. KlEE. Vol. 50p. pp. 125-129, 2001
  6. O. Kukrer, 'Discrete-Time Current Control of Voltage-Fed Three-Phase PWM Inverters', IEEE Trans. Power Electronics, Vol. 11, No.2, pp. 260-269, 1996 https://doi.org/10.1109/63.486174
  7. Takeo, N. T. and Hirofumi, A. G., 'Pulse-density modulation of a high-frequency voltgage-source inverter', IEEJ Trans. IA, Vol. 125, pp. 413-419, 2005 https://doi.org/10.1541/ieejias.125.413
  8. Shengpei, W. and Konishi, Y. H., 'Series-compensated inductor type resonant inverter using pulse density modulation scheme for efficient ozonizer', IEEE, 7803, pp. 19-23, 1997
  9. O. Kukrer, 'Deadbeat Control of a Three-Phase Inverter with an Output LC Filter', IEEE Trans. Power Electronics, Vol. 11, No.1, pp. 16-23, 1996 https://doi.org/10.1109/63.484412
  10. Junya, S. H. and Masanori, H., 'Improvement of the ozone generation effciency by silent discharge at cryogenic temperature', IEEJ Trans. FM124, pp. 791-796, 2004
  11. Y. Ito and S. Kawauchi, 'Microprocessor-Based Robust Digital Control for UPS with Three-Phase PWM Inverter', lEEE Trans. Power Electronics, Vol. 10, No.2, pp. 196-204, 1995 https://doi.org/10.1109/63.372604
  12. Lee, S. K. Lee, K. S. and Park, J. H., 'A study on the supply gas temperature characteristics of silent discharge type ozonizer by applying radio frequency voltage', Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol. 15, pp. 46-54, 2001