References
- J. Nielsen, S. H. Jensen, 'Some experimental and clinical lights on rotation therapy, its basis and possibilities,' Acta. Radiologic., Vol. 23, pp. 51-66, 1942 https://doi.org/10.3109/00016924209176854
- A. G. Haus, 'Historical developments in film processing and medical imaging, in Haus AG(ed) : Film processing and medical imaging,' Wisconsin, Medical Physics Publshing, 1993
- A. L. Boyer, L. Antonuk, A. Fenster, et al. 'A review of electronic portal imaging devices (EPIDs),' Med. Phys., Vol. 19, pp. 1-16, 1992 https://doi.org/10.1118/1.596878
- P. Munro, J. A. Rawlinson, A. Fenster, 'A digital fluoroscopic imaging device for radiotherapy localization,' Int. J. Radiat. Oncol. Biol. Phys., Vol. 18, pp. 641-649, 1990 https://doi.org/10.1016/0360-3016(90)90073-S
- K. S. Lam, M. Partowmah, W. C. Lam, 'An on-line electronic portal imaging system for external beam radiotherapy,' Br. J. Radiol., Vol. ?59, pp. 1007-1013, 1986 https://doi.org/10.1259/0007-1285-59-706-1007
- E. J. Morton, W. Swindell, D. G. Lewis, et al., 'A linear array, scintillation crystal-photodiode detector for megavoltage imaging,' Med. Phys., Vol. 18, pp. 681-691, 1991 https://doi.org/10.1118/1.596661
- G. Barnea, E. Navon, A. Ginzburg, et al., 'Use of storage phosphor imaging plates in portal imaging and high-energy radiography: the intensifying effect of metallic screens on the sensitivity,' Med. Phys., Vol. 18, pp, 432-438, 1991 https://doi.org/10.1118/1.596690
- M. K. Islam, L. T. Fitzgerald, F. J. Bova, et al., 'A coded aperture device for on-line imaging with megavoltage photon beams,' Phys. Med. Biol., Vol. 38, pp. 1403-1418, 1993 https://doi.org/10.1088/0031-9155/38/10/003
- M. V. Herk, H. Meertens, 'A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy,' Radiother. Oncol., Vol. 11, pp, 369-378, 1988 https://doi.org/10.1016/0167-8140(88)90208-3
- L. E. Antonuk, J. Boudry, W. Huang, et al., 'Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays,' Med. Phys., Vol. 19, pp. 1455-1466, 1992 https://doi.org/10.1118/1.596802
- E. C. McCullough, K. P. McCollough, 'Improving agreement between radiation-delineated field edges on simulation and portal films : The edge tolerance test tool,' Med. Phys., Vol. 20, pp. 375-376, 1993 https://doi.org/10.1118/1.597129
- K. Luchka 'Assessing radiation and light field congruence with a video based electronic portal imaging device,' Med. Phy., Vol. 23(7), pp. 1245-1252, 1996 https://doi.org/10.1118/1.597867
- A. C. Savard, E. B. Podgorsak, 'An electronic portal imaging device as a physics tool,' Medical Dosimetry, Vol. 22(2), pp. 101-105, 1997 https://doi.org/10.1016/S0958-3947(97)00002-2
- T. R. McNutt, T. R. Mackie, B. R. Paliwal, 'Analysis and convergence of the iterative convolution/superposition dose reconstruction technic for multiple treatment beams and tomotherapy,' Med. Phys., Vol. 24(9), pp. 1465-1476, 1997 https://doi.org/10.1118/1.598035
- S. Hamers, J. Freyschmidt, U. Neitzel, 'Digital radiography with a large-scale electronic flat-panel detector vs screen-film radiography: observer preference in clinical skeletal diagnostics,' Eur. Radiol. 11:1753-1759, 2001 https://doi.org/10.1007/s003300100830
- Terue Okamura, Saori Tanaka, et al. 'clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen,' Eur. Radiol. 12:1741-1747, 2002 https://doi.org/10.1007/s00330-001-1283-0